Log in to see the plans as drawn SITE
COMMUNITY FACILITIES
PALM LAKE RESORT
19 TRADING POST ROAD
COOROY, QLD
SCHEDULE OF ARCHITECTURAL DRAWINGS
DRAWING No. DRAWING TITLE SCALE @ B1 ISSUE
COOROY CC00 COVER SHEET AS SHOWN A
CC101 CLUB HOUSE SITE PLAN 1:200 B
CC102 CLUB HOUSE FLOOR PLAN 1:100 B
CC103 CLUB HOUSE ROOF PLAN 1:100 B
CC105 CLUB HOUSE ELEVATIONS 1:100 B
1 LOCALITY PLAN
NTS
Schedule of Finishes
LEGEND
Area Material Finish Colour TRADING POST ROAD MAIN ENTRY POINTS
POOL
External APPROXIMATE EXTENT OF DEEP
SOIL SOFT LANDSCAPING TO
Hardstand, Parking and Driveways Concrete Oxide pigments Charcoal LANDSCAPE ARCHITECTS DETAILS.
Porte Cochere feature paving Stone pavers Natural To be Selected
Roof Steel Colorbond Selected ‘dark’ colours NOTES:
External Wall 1 Lightweight masonry Textured acrylic paint Selected ‘light’ colours DETENTION
POND
CLUB HOUSE DETENTION
POND
REFER CC102 1. FINISHED FLOOR LEVEL INDICATIVE ONLY.
External Wall 2 Fibre Cement Sheet System Paint Selected ‘light’ colours TO BE CONFIRMED SUBJECT TO FINAL CIVIL
Window frames Aluminium Powdercoat Selected ‘medium’ colours ENGINEERS DETAILS AND LEVELS
Window Glass Toughened where required Clear
2. CAR SPACES:
External Doors Frames Steel Galvanized and paint Selected ‘medium’ colours CLUB HOUSE 20
External Doors Solid core paint grade Paint Selected ‘light’ colours
Screens and Blades Composite timber Prefinished To be selected
External Paving Concrete Tile Prefinished Selected ‘medium’ colours SCHEDULE OF FLOOR AREAS
Perimeter pathways Concrete Oxide pigments To be selected CLUB HOUSE GFA 2,100.6m2
MAIN ACCESS ROAD
Entry areas to pool surrounds Composite concrete system Aggregate finish Selected ‘light’ colours MAIN DECK AND CRAFT DECK 222.8m2
Feature pool deck areas Composite timber boards Prefinished To be selected AREA BELOW ROOF OF PORTE COCHERE 144.6m2
APPROX. POOL ENCLOSURE 805m2
Internal
APPROX. BBQ AREA 80m2
Floor – Main rooms Carpet To be selected To be selected
Floor – High traffic and dance floor Timber parquetry Sealed and polished To be selected GROSS FLOOR AREA MEASURED TO
EXTERNAL FACE OF EXTERNAL WALLS
Floor and walls - Wet areas Ceramic tile To be selected Selected ‘light’ colours
Floor – Kitchen Vinyl sheeting To be selected Selected ‘medium’ colours
Walls – General Plasterboard Paint White
Ceilings – General Plasterboard Paint White
1 COMMUNITY FACILITIES SITE PLAN
1:500
Drawing Title:
paa.design
Architect : Client : Site Address: Project Name:
Peter Andrews + Associates PTY LTD
PALM LAKE RESORT COMMUNITY FACILITIES CLUB HOUSE COVER SHEET
Architecture . Planning . Urban Design
19 TRADING POST ROAD Stage: CONSTRUCTION Project No: Issue:
A 15.10.2015 ISSUE FOR DEVELOPMENT APPLICATION PO Box 494 Terrigal NSW 2260 Scale:
CERTIFICATE 14_085
COOROY, QLD
A
P:: + 61 2 4385 9126 ALL DIMENSIONS AND LEVELS TO BE CHECKED ON SITE BY CONTRACTOR PRIOR TO
Issue No. Date Description CONSTRUCTION. REFERENCE FIGURED DIMENSIONS ONLY, DO NOT SCALE DRAWINGS. Issue Date: Drawing No.
E:: [email protected] Nominated Architect - Peter Andrews
Amendments W:: www.paadesign.com.au (Architect Registration No: 3687) on B1 sheet ALL BOUNDARIES AND LEVELS SUBJECT TO SURVEY. 15/10/2015 CC000
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLarge file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 4 pages
Page 2
POOL ENCLOSURE TO
FUTURE DETAIL &
SETOUT -
CC___
BBQ AREA
DECK
POOL
(BY OTHERS)
LEGEND
APPROXIMATE EXTENT OF DEEP SOIL SOFT
DECK LANDSCAPING. REFER TO LANDSCAPE DETAILS
SPA
POOL FENCING BY OTHERS
BUILDING SETOUT POINTS
(TO BE VERIFIED PRIOR TO CONSTRUCTION)
ACCESSIBLE CAR PARKING SPACE
TO COMPLY WITH AS1428.1 & 2890.6
BOUNDARY
-
NOTES
CC102 1. ROAD LAYOUT TO CIVIL ENGINEER'S DETAILS. LOCATION
TO BE VERIFIED BY SURVEY.
2. BUILDING SETOUT FROM CIVIL ENGINEER'S ROAD
LAYOUT PROVIDED BY CLIENT
3. BUILDING TO BE PEGGED OUT PRIOR TO CONSTRUCTION
LANDSCAPING
CLUB
4. ALL RAMPS AND HANDRAILS TO AS 1428.1.
HOUSE
5. KERB TO BE ROLL OVER TYPE TO CIVIL ENGINEER'S
DETAIL.
6. HOSE COCK LOCATIONS TO BE ADVISED BY HYDRAULIC
DETENTION CONSULTANT. PILLAR COCK FIXED TO ADJACENT WALL
POND UNLESS NOTED OTHERWISE.
7. GENERAL LOCATION AND SIZE OF SWIMMING POOLS
SHOWN. POOL STRUCTURE AND OPERATION TO POOL
CONSULTANT / CONTRACTORS DETAILS AND
SPECIFICATION. SHADE STRUCTURE AND POOL FENCE TO
DETENTION BE DESIGNED AND DETAILED BY SPECIALIST POOL
BUILDING SETOUT FROM FACE OF KERB PERPENDICULAR TO ROAD
POND CONSULTANT. ALL WORKS TO COMPLY WITH ALL RELEVANT
AUSTRALIAN STANDARDS, THE BCA AND LOCAL AUTHORITY
REQUIREMENTS.
LOADING
DOCK 8. POOL FENCING AND GATES - BY POOL CONSULTANT TO
COMPLY WITH ALL RELEVANT AUSTRALIAN STANDARDS,
BCA AND LOCAL AUTHORITY REQUIREMENTS.
9. FOR THE FOLLOWING REFER TO LANDSCAPE DETAILS
UNLESS NOTED OTHERWISE:
1,000 3,000 - PATHWAY AND COURTYARD PAVING
17,575
LANDSCAPING - SOFT LANDSCAPE / GARDENING
PUMP - FENCES AND EDGES
LANDSCAPING
HOUSE 10. ALL ROADS AND PARKING BAY MARKINGS TO COMPLY
1,500
PATH WITH RELEVANT AUSTRALIAN STANDARDS AND CIVIL
PORTE ENGINEERS DETAILS.
__ COCHERE
CC___ 11. POOL HEATING TO BE GAS BOOSTED SOLAR TO
HYDRAULIC CONSULTANT DETAIL.
TYPICAL
SHARED
SHARED
AREA
AREA
5,500
1,500 1,500
PATH
2,600 7,500
TYPICAL
BUILDING SETOUT FROM
FACE OF KERB
MAIN ACCESS ROAD
LOT 104 LOT 90 LOT 89 LOT 74 LOT 57 LOT 42 LOT 41
Drawing Title:
paa.design
Architect : Client : Site Address: Project Name:
Peter Andrews + Associates PTY LTD
PALM LAKE RESORT COMMUNITY FACILITIES CLUB HOUSE SITE PLAN
Architecture . Planning . Urban Design NORTH
B 15.10.2015 ISSUE FOR DEVELOPMENT APPLICATION 19 TRADING POST ROAD Stage: CONSTRUCTION Project No: Issue:
A 25.09.2015 DRAFT ISSUE PO Box 494 Terrigal NSW 2260 Scale:
CERTIFICATE 14_085
COOROY, QLD
B
P:: + 61 2 4385 9126 ALL DIMENSIONS AND LEVELS TO BE CHECKED ON SITE BY CONTRACTOR PRIOR TO
Issue No. Date Description 1:200 CONSTRUCTION. REFERENCE FIGURED DIMENSIONS ONLY, DO NOT SCALE DRAWINGS. Issue Date: Drawing No.
E:: [email protected] Nominated Architect - Peter Andrews
Amendments W:: www.paadesign.com.au (Architect Registration No: 3687) on B1 sheet ALL BOUNDARIES AND LEVELS SUBJECT TO SURVEY. 15/10/2015 CC101
Page 3
70,660
5,725 27,225 3,000 15,995 5,230 9,525 3,360 600
SERVICE
CRAFT DECK
5,700
BOWLING ALLEY IS INDICATIVE ONLY.
REFER SPECIALIST CONSULTANT DETAILS
NOTES:
8,735
INCLUDING SLAB SETDOWN
1. DO NOT SCALE DRAWINGS.
2. VERIFY ALL DIMENSIONS AND RESOLVE ANY DISCREPANCIES WITH THE SUPERINTENDENT
PRIOR TO CONSTRUCTION. REFER TO SPECIFICATIONS, PROJECT REQUIREMENTS, NOTES
AND DESCRIPTION OF ABBREVIATIONS.
3. LEVELS SHOWN ARE APPROXIMATE ONLY AND HAVE BEEN BASED ON THE PRELIMINARY
PROVIDED DESIGN LEVELS. CONTRACTOR TO VERIFY ALL LEVELS ON SITE BEFORE
FALL
FALL
FALL
MAIN DECK COMMENCEMENT OF ANY WORK.
4. CONTROL JOINTS ARE TO BE PROVIDED IN ACCORDANCE WITH ENGINEERS SPECIFICATION
AND MANUFACTURERS REQUIREMENTS.
FIREPLACE
6,490
CRAFT 5. ALL DRIVEWAY GRADES TO BE CONFIRMED ON SITE AND TO BE ADJUSTED IF REQUIRED TO
COMPLY WITH RELEVANT AUSTRALIAN STANDARDS.
FALL
7. SLAB SET DOWN DETAILS, SLAB DESIGN AND SPECIFICATIONS TO BE IN ACCORDANCE
FALL JOINERY WITH ENGINEERS SPEC. & DETAILS.
TO FUTURE DETAIL
8. ALL SLAB PENETRATIONS FOR BUILDING SERVICES INSTALLATIONS TO BE COORDINATED
AND CONFIRMED ON SITE BY CONTRACTOR.
9. ROOF PENETRATIONS ARE NOT SHOWN, TO BE ALLOWED FOR AND COORDINATED BY
SPA CONTRACTOR.
7,395
10. DOWNPIPE LOCATION TO BE CONFIRMED BY HYDRAULIC CONSULTANT.
11. ROOF PITCH IS 15° UNLESS NOTED OTHERWISE.
2,100
BAR FITOUT IS INDICATIVE
ONLY. FITOUT INCLUDING 12. LOCATION OF GAS HOT WATER UNITS TO HYDRAULIC ENGINEER'S DETAILS.
BAR FRONT BY SPECIALIST
CONSULTANT 13. FIRE RATED WALLS WHERE REQUIRED TO BE SEALED TO UNDERSIDE OF ROOF SHEETING
TO MAINTAIN FIRE RATING.
JOINERY
14. INSULATION EQUAL TO:
BAR TO FUTURE DETAIL EXTERNAL WALLS - R2.8
INTERNAL WALLS (POOL AREA) - R1.8
ROOF SPACE - R3.7
FALL
FALL
HYDRO LIFT TO
MANUFACTURERS DETAILS
BILLIARDS
7,580
LOCATION TO BE STAGE DANCE FLOOR MAIN HALL
CONFIRMED ON SITE CLUB
POOL
PLANT
LEGEND
SAUNA FITOUTS INCLUDING ACCESS
HEATER AND ENTRY DOORS TO CJ CONSTRUCTION JOINT
SPECIALIST CONTRACTORS
WC 2
DETAIL AND SPECIFICATION DP DOWNPIPE - STEEL COLORBOND FINISH
STORE
INDOOR COLOUR TO BE SELECTED
POOL EMB ELECTRICAL METER BOARD - TO ELECTRICAL
CONSULTANT'S DETAIL
NOTE: SC STEEL COLUMN REFER STRUCTURAL
13,340
ACCESS
2,100
GENERAL LOCATION AND SIZE ENGINEERS DETAIL
SAUNA OF POOL SHOWN. POOL WC 3
STRUCTURE AND OPERATION A/C LOCATION FOR A/C COMPRESSORS
MALE
47,810
TO POOL CONSULTANT / NOTE: BOWLING TO MECHANICAL CONSULTANT'S DETAILS
CONTRACTORS DETAILS AND COLUMN SETOUT TO SIT ALLEY DOOR
SPECIFICATION. ALL WORKS FLUSH WITH DANCE FLOOR CIRCULATION DOOR CIRCULATION AREA
TO COMPLY WITH AUSTRALIAN TO COMPLY WITH AS 1428 & BCA
STANDARDS AND THE BCA.
CORRIDOR 1
POOL TO BE ACCESSIBLE
FLOOR WASTE
ACOUSTIC INSULATION TO BE ADVISED
FEMALE GLASS BALUSTRADE
WITH GATE FINISHES:
LIBRARY
8,390
SAUNA TO FUTURE DETAIL BOWLING CPT CARPET - TO BE SELECTED
FIREPLACE AND SURROUND LOUNGE
TO FUTURE DETAIL CTILE CERAMIC TILE - TO BE SELECTED
FALL
CONC CONCRETE
TILE 1 GLAZED VITRIFIED FLOOR TILE - TO BE SELECTED
SPORTS
2,600
LOBBY ADMIN WC TILE 2 EXTERNAL TILE - TO BE SELECTED
CORRIDOR 3 CORRIDOR 2
SERVERY TILE 3 NON SLIP TILE TO POOL SURROUND - TO BE SELECTED
TIMBER TIMBER PARQUETRY EQUAL TO BORAL
AV CPD FHR COFFEE
CPD HARDWOOD PARQUETRY SYSTEM.
ACCESS TIMBER TO BE SELECTED
SCREEN INSTALLATION TO WC 1 KITCHEN STORE
CINEMA CONSULTANTS DETAIL OFFICE
MALE
WC BUILDING
MULTI-PURPOSE ENTRY SETOUT POINT
GYM HALL
6,075
FEMALE HAIR
PABX
WC DRESSER KITCHEN LAYOUT IS INDICATIVE ONLY
8,965
FOYER FIRE RATED PLASTERBOARD TO FITOUT INCLUDING STORES AND SERVERY
ALL PARTITIONS IN PABX ROOM BY KITCHEN CONTRACTOR BIN STORE
TO ELECTRICAL ENGINEERS
SPECIFICATION
SEATING SELECTION TO CINEMA
CONSULTANTS DETAIL
FINISHES TO COMPLY WITH
AUSTRALIAN STANDARDS AND BCA
ALUMINIUM SCREEN & GATE LINE OF ROOF OVER
TO FUTURE DETAIL SHOWN DASHED
METAL SCREENS TO
FUTURE DETAIL
9,375
PORTE
COCHERE
6,775
LINE OF KERB, REFER TO
SITEPLAN FOR EXTENT
STEEL POSTS TO STRUCTURAL
ENGINEER'S DETAILS. CLAD IN
LIGHTWEIGHT MASONRY TO MATCH
GENERAL WALL FINISH
WATER FEATURE, SIGNAGE AND LIGHTING
TO SPECIALIST CONTRACTORS DETAIL
7,475 9,000 15,050 5,850 22,550 6,775 3,360 600
Drawing Title:
paa.design
Architect : Client : Site Address: Project Name:
Peter Andrews + Associates PTY LTD
PALM LAKE RESORT COMMUNITY FACILITIES CLUB HOUSE FLOOR PLAN
Architecture . Planning . Urban Design
B 15.10.2015 ISSUE FOR DEVELOPMENT APPLICATION 19 TRADING POST ROAD Stage: CONSTRUCTION Project No: Issue:
A 25.09.2015 DRAFT ISSUE PO Box 494 Terrigal NSW 2260 Scale:
CERTIFICATE 14_085
COOROY, QLD
B
P:: + 61 2 4385 9126 ALL DIMENSIONS AND LEVELS TO BE CHECKED ON SITE BY CONTRACTOR PRIOR TO
Issue No. Date Description 1:100 CONSTRUCTION. REFERENCE FIGURED DIMENSIONS ONLY, DO NOT SCALE DRAWINGS. Issue Date: Drawing No.
E:: [email protected] Nominated Architect - Peter Andrews
Amendments W:: www.paadesign.com.au (Architect Registration No: 3687) on B1 sheet ALL BOUNDARIES AND LEVELS SUBJECT TO SURVEY. 15/10/2015 CC102
Page 4
LEGEND
DP DOWNPIPE - STEEL COLORBOND FINISH
COLOUR TO BE SELECTED
FINISHES:
ROOF - EQUAL TO COLORBOND 0.48mm CUSTOM ORB. COLOUR TO BE SELECTED
GUTTERS - COLORBOND. COLOUR TO MATCH ROOF
DOWNPIPES - COLORBOND. COLOUR TO MATCH WALL
FASCIAS & BARGE BOARDS - COLOUR TO MATCH ROOF
CAPPING - COLOUR TO MATCH ROOF
NOTES:
1. DO NOT SCALE DRAWINGS.
2. VERIFY ALL DIMENSIONS AND RESOLVE ANY DISCREPANCIES WITH THE SUPERINTENDENT
PRIOR TO CONSTRUCTION. REFER TO SPECIFICATIONS, PROJECT REQUIREMENTS, NOTES
AND DESCRIPTION OF ABBREVIATIONS.
FALL
3. LEVELS SHOWN ARE APPROXIMATE ONLY AND HAVE BEEN BASED ON THE PRELIMINARY
PROVIDED DESIGN LEVELS. CONTRACTOR TO VERIFY ALL LEVELS ON SITE BEFORE
COMMENCEMENT OF ANY WORK.
4. CONTROL JOINTS ARE TO BE PROVIDED IN ACCORDANCE WITH ENGINEERS SPECIFICATION
AND MANUFACTURERS REQUIREMENTS.
5. ALL DRIVEWAY GRADES TO BE CONFIRMED ON SITE AND TO BE ADJUSTED IF REQUIRED TO
COMPLY WITH RELEVANT AUSTRALIAN STANDARDS.
7. SLAB SET DOWN DETAILS, SLAB DESIGN AND SPECIFICATIONS TO BE IN ACCORDANCE
WITH ENGINEERS SPEC. & DETAILS.
FALL
8. ALL SLAB PENETRATIONS FOR BUILDING SERVICES INSTALLATIONS TO BE COORDINATED
AND CONFIRMED ON SITE BY CONTRACTOR.
9. ROOF PENETRATIONS ARE NOT SHOWN, TO BE ALLOWED FOR AND COORDINATED BY
CONTRACTOR.
10. DOWNPIPE LOCATION TO BE CONFIRMED BY HYDRAULIC CONSULTANT.
11. ROOF PITCH IS 15° UNLESS NOTED OTHERWISE.
12. LOCATION OF GAS HOT WATER UNITS TO HYDRAULIC ENGINEER'S DETAILS.
13. FIRE RATED WALLS WHERE REQUIRED TO BE SEALED TO UNDERSIDE OF ROOF SHEETING
TO MAINTAIN FIRE RATING.
14. INSULATION EQUAL TO:
EXTERNAL WALLS - R2.8
INTERNAL WALLS (POOL AREA) - R1.8
ROOF SPACE - R3.7
FALL
FALL
FALL
FALL
FALL
FALL
FALL
FALL
FALL
FALL
FALL
FALL
FALL
FALL
FALL FALL
LINE OF EXTERNAL
WALL BELOW
COLORBOND ROOF SHEETING
EQUAL TO CUSTOM ORB 0.48mm
COLORBOND QUAD EAVES GUTTER
FALL
FALL
Drawing Title:
paa.design
Architect : Client : Site Address: Project Name:
Peter Andrews + Associates PTY LTD
PALM LAKE RESORT COMMUNITY FACILITIES CLUB HOUSE ROOF PLAN
Architecture . Planning . Urban Design
B 15.10.2015 ISSUE FOR DEVELOPMENT APPLICATION 19 TRADING POST ROAD Stage: CONSTRUCTION Project No: Issue:
A 25.09.2015 DRAFT ISSUE PO Box 494 Terrigal NSW 2260 Scale:
CERTIFICATE 14_085
COOROY, QLD
B
P:: + 61 2 4385 9126 ALL DIMENSIONS AND LEVELS TO BE CHECKED ON SITE BY CONTRACTOR PRIOR TO
Issue No. Date Description 1:100 CONSTRUCTION. REFERENCE FIGURED DIMENSIONS ONLY, DO NOT SCALE DRAWINGS. Issue Date: Drawing No.
E:: [email protected] Nominated Architect - Peter Andrews
Amendments W:: www.paadesign.com.au (Architect Registration No: 3687) on B1 sheet ALL BOUNDARIES AND LEVELS SUBJECT TO SURVEY. 15/10/2015 CC103
Page 5
COLORBOND ROOF SHEETING
AT 15°PITCH
RIDGE RIDGE
RL __.___ RL __.___
3,560
4,860
THEATRE
CL __.___
7,860
2,200
MAIN CLUB
CL __.___
THEATRE
FL __.___
3,000
2,100
MAIN CLUB MAIN CLUB
FL RL __.___ FL RL __.___
VERTICAL SCREEN PAINTED FC CLADDING TEXTURED PAINT TO HEBEL VERTICAL SCREEN HORIZONTAL SCREEN
1 SOUTHWEST ELEVATION
COLORBOND ROOF SHEETING
AT 15°PITCH
RIDGE RIDGE
RL __.___ RL __.___
3,560
4,860
LEGEND
THEATRE
CJ CONSTRUCTION JOINT
CL __.___
7,860
EMB ELECTRICAL METER BOARD
2,200
MAIN CLUB
FINISHES:
CL __.___
THEATRE BAL BALUSTRADE - COLOUR TO BE SELECTED
FL __.___
CP LIGHTWEIGHT CEMENT PANEL WITH TEXTURED
3,000
PAINT FINISH - EQUAL TO HEBEL POWER PANEL
2,100
WITH SUITABLE DULUX ACRATEX SYSTEM
DP DOWNPIPE - STEEL COLORBOND FINISH
MAIN CLUB MAIN CLUB COLOUR TO BE SELECTED
GL
FL RL __.___ FL RL __.___
FC FIBRE CEMENT SHEETING WITH PAINT FINISH
MR CUSTOM ORB COLORBOND 0.48mm ROOF SHEETING
TEXTURED PAINT TO HEBEL VERTICAL SCREEN PAINTED FC CLADDING
- COLOUR TO BE SELECTED
2 NORTHWEST ELEVATION RB BRICKWORK WITH RENDER AND PAINT FINISH
WB FIBRE CEMENT WALL CLADDING - EQUAL TO JAMES
HARDIES SCYON STRIA PAINT FINISH
COLOUR TO BE SELECTED
SC STEEL COLUMN - PAINT FINISH / COLOUR
TO BE SELECTED
COLORBOND ROOF SHEETING
AT 15°PITCH
NOTES:
RIDGE
1. GUTTERS AND DOWNPIPES TO COMPLY WITH AS 3005.3
RL __.___
2. ALLOW ANTICON 95 ROOF BLANKET OR EQUAL TO ALL
ROOFS ABOVE CONDITIONED SPACES.
3. ALLOW BRADFORD GOLD R2.0 BATTS OR EQUAL TO ALL
EXTERNAL WALLS.
4,860
4. IF REQUIRED ALLOW BRADFORD GOLD R1.5 BATTS OR
EQUAL TO ALL INTERNAL ENVELOPE WALLS.
7,860
MAIN CLUB
CL __.___
3,000
MAIN CLUB
GL
FL RL __.___
VERTICAL SCREEN TEXTURED PAINT TO HEBEL POOL FENCE
3 NORTHEAST ELEVATION
COLORBOND ROOF SHEETING
AT 15°PITCH
RIDGE
RL __.___
4,860
7,860
MAIN CLUB
CL __.___
3,000
MAIN CLUB
GL
FL RL __.___
TEXTURED PAINT TO HEBEL VERTICAL SCREEN
4 SOUTHEAST ELEVATION
Drawing Title:
paa.design
Architect : Client : Site Address: Project Name:
Peter Andrews + Associates PTY LTD
PALM LAKE RESORT COMMUNITY FACILITIES CLUB HOUSE ELEVATIONS
Architecture . Planning . Urban Design
B 15.10.2015 ISSUE FOR DEVELOPMENT APPLICATION 19 TRADING POST ROAD Stage: CONSTRUCTION Project No: Issue:
A 25.09.2015 DRAFT ISSUE PO Box 494 Terrigal NSW 2260 Scale:
CERTIFICATE 14_085
COOROY, QLD
B
P:: + 61 2 4385 9126 ALL DIMENSIONS AND LEVELS TO BE CHECKED ON SITE BY CONTRACTOR PRIOR TO
Issue No. Date Description 1:100 CONSTRUCTION. REFERENCE FIGURED DIMENSIONS ONLY, DO NOT SCALE DRAWINGS. Issue Date: Drawing No.
E:: [email protected] Nominated Architect - Peter Andrews
Amendments W:: www.paadesign.com.au (Architect Registration No: 3687) on B1 sheet ALL BOUNDARIES AND LEVELS SUBJECT TO SURVEY. 15/10/2015 CC105