Council archive · source document
Building plans · 142007.743.03
Plans and drawings: the text below has words only, no drawings.
2752
EXISTING
PROPOSED DWELLING
300 POOL
1900
There is to be no direct access from the house into the pool
enclosure area. A complying fence, including a solid wall of the
house, must separate the pool enclosure area from the house in
accordance with AS.1926.1 and QDC MP3.4 Swimming pool
barriers. Prior to the pool being filled to a depth of 300 mm, the pool
fencing must be inspected, approved and a Form 17 issued by the
building certifier. A resuscitation sign must be displayed near the
pool in accordance with ANZCOR guideline 8 - Cardiopulmonary
Resuscitation (CPR) published by the Australian Resuscitation
Council in April 2021.
SITE PLAN
1 : 200
Swimming pool backwash must be
RPD
connected to the sewer in accordance
LOT 2 ON SP236316
LOCAL GOV.: NOOSA SHORE COUNCIL
with Council requirements.
LOCALITY: SUNRISE BEACH
AREA - 304m²
D:\Projects\On Trend\36 Ventura st, Sunrise Beach\POOL_01.rvt
ISSUE DATE AMENDMENTS Client Drawing Title:
1 11/07/2023 BA ISSUE TIM & LIDIA McNAMARA SITE PLAN
Revision
ABN 80644413445
QBCC LIC No. 15225783
1
e: [email protected]
0412 411 810 Scale: 1 : 200 Date: 11/07/2023
t: 0439 676 205 [email protected]
Status: BA PLAN Drawn By: DAN JARVIS
Address
QBCC LIC NO.: 15027450
NORTH UNIT 2, 36 VENTURA STREET, SUNRISE Project No: Drawing No:
COPYRIGHT BEACH
THIS DRAWING IS PROTECTED BY COPYRIGHT. NO PART OF THIS DRAWING IS TO BE
REPRODUCED IN ANY FORMAT AS IT WOULD BREACH COPYRIGHT ACT OF 1968. 36VEN 01
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 pages
Page 2
1900 3000 3400
POOL FENCING AND GATES
MUST COMPLY WITH BOUNDARY FENCE TO QDC MP3.4
// // // // // // // // // // // // // // // // // // // // // // // //
AS1926.1, THE QUEENSLAND
DEVELOPMENT CODE - PART
957
//
//
3.4, THE BUILDING ACT 1975
AND THE BUILDING
//
//
REGULATION 2021 ST
EP
//
//
STEP
SELECTED NON-SLIP TILES
1795
POOL GATE
//
//
0
30
0
30
//
//
//
//
25
450
BENCH SEAT 500 DEEP
0
D
EE
P
1200 DEEP
//
//
75
R
GLASS POOL BARRIER AND GATE TO QDC MP3.4
0
VE
D
EE
ONY O
P
//
//
G BALC
LED LIGHT
//
//
EXISTIN
EXISTING DWELLING
2
//
//
POOL
POOL
RETURN
SUCTION
BOUNDARY FENCE TO QDC MP3.4
//
//
6000
//
//
5550
SKIMMER
BOX
//
//
POOL
//
//
RETURN
LED LIGHT
POOL
EXISTING PATIO
//
//
SUCTION
MAIN DRAIN
//
//
& HV
//
//
WATER
//
//
FEATURE 1800 DEEP
190
300
// // // // // // // // // // // // //
1400 HIGH CONCRETE
BOUNDARY FENCE TO QDC MP3.4 BLOCK WALL
1
POOL PLAN
1 : 50
D:\Projects\On Trend\36 Ventura st, Sunrise Beach\POOL_01.rvt
ISSUE DATE AMENDMENTS Client Drawing Title:
1 11/07/2023 BA ISSUE TIM & LIDIA McNAMARA POOL PLAN
Revision
ABN 80644413445
QBCC LIC No. 15225783
1
e: [email protected]
0412 411 810 Scale: 1 : 50 Date: 11/07/2023
t: 0439 676 205 [email protected]
Status: BA PLAN Drawn By: DAN JARVIS
Address
QBCC LIC NO.: 15027450 UNIT 2, 36 VENTURA STREET, SUNRISE Project No: Drawing No:
COPYRIGHT BEACH
THIS DRAWING IS PROTECTED BY COPYRIGHT. NO PART OF THIS DRAWING IS TO BE
REPRODUCED IN ANY FORMAT AS IT WOULD BREACH COPYRIGHT ACT OF 1968. 36VEN 02
Page 3
POOL COPING
6000 (AS SELECTED)
5550 450 50
WATERBLADE -
1200 LONG
FREEBOARD
1400
PIPEWORK
BEHIND WALL
SELECTED STONE POOL COPING
FINISH TO POOL AND
SIDES (AS SELECTED)
WATERLINE TILES
(AS SELECTED)
500
PEBBLECRETE
1200
(AS SELECTED)
1800
POOL SHELL TO
ENGINEERS DETAILS
COPING DETAIL
1 : 10
MAIN DRAN
& HV
POOL SECTION 1
1 : 50
POOL COPING
(AS SELECTED)
250
500
750
1200
POOL SECTION 2
1 : 50
ARTIST IMPRESSION
D:\Projects\On Trend\36 Ventura st, Sunrise Beach\POOL_01.rvt
ISSUE DATE AMENDMENTS Client Drawing Title:
1 11/07/2023 BA ISSUE TIM & LIDIA McNAMARA DETAILS
Revision
ABN 80644413445
QBCC LIC No. 15225783
1
e: [email protected]
0412 411 810 Scale: As indicated Date: 11/07/2023
t: 0439 676 205 [email protected]
Status: BA PLAN Drawn By: DAN JARVIS
Address
QBCC LIC NO.: 15027450 UNIT 2, 36 VENTURA STREET, SUNRISE Project No: Drawing No:
COPYRIGHT BEACH
THIS DRAWING IS PROTECTED BY COPYRIGHT. NO PART OF THIS DRAWING IS TO BE
REPRODUCED IN ANY FORMAT AS IT WOULD BREACH COPYRIGHT ACT OF 1968. 36VEN 03