10. An access driveway for the dwelling must be provided from the edge of the formation in
Schreibers Road to the parking and manoeuvring areas of the dwelling. The works must be
undertaken in accordance with an Operational Works approval submitted in conjunction with
the building application for the dwelling. The works must include in particular a driveway
crossover generally in accordance with Council’s Standard drawing RS-056

Stormwater Drainage

11. Stormwater runoff from the development must be disposed of on-site without causing scour
or damage to the subject site or any adjoining property.

Earthworks

12. Allearthworks and associated walls/batters must be contained entirely within the subject site
unless written permission from the respective landowner(s) is provided to Council. All
earthworks must be undertaken in accordance with the provisions of Australian Standard
AS3798: Guidelines on Earthworks for Commercial and Residential Developments.

Damage to Services and Assets

13. Any damage caused to existing services and assets as a result of the development works
must be repaired at no cost to the asset owner at the following times:

a. where the damage would cause a hazard to pedestrian or vehicle safety, immediately;
or

b. — where otherwise, upon completion of the works associated with the development.

Any repair work which proposes to alter the alignment or level of existing services and assets
must first be referred to the relevant service authority for approval.

Water Supply

14. The development must be provided with a potable water supply having a capacity sufficient
for the use.

Waste Water Treatment and Disposal

15. The development must be provided with an on-site waste water treatment and effluent
disposal system having a capacity sufficient for the use*.

*(Refer to Advisory Note)
Bushfire Management

16. Anon-site water supply available for firefighting purposes must be provided, having a volume
of not less than 5,000 litres. The water supply may be either:

a. aseparate tank

b. a reserve section in the bottom part of the main water supply tank

c. adam

d. | aswimming pool installed immediately upon construction of the home.
5. REFERRAL AGENCIES

Not applicable.

Document Set ID: 21099779 Page 3 of 6
Version: 3, Version Date: 10/03/2020 Print Date: 10 March 2020, 11:31 AM
Log in to download the original file

Attachement 5 - Copy of original MCU.pdf · 5.6 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.