Council archive · source document
Attachment 3 - Amended Building Approval · RAL20/0005
ELEVATIONS - ELEVATION LEGEND
ALL CLADDING SYSTEMS NOTED TO BE
GENERAL NOTES FIXED IN ACCORDANCE WITH THE RELEVANT
MANUFACTURERS SPECIFICATIONS.
OVERALL HEIGHTS SHOWN ARE MEASURED FROM FFL. ARN - ACRA TEX RENDER (DULUX) PF SFGLASS - POOL FENCE - SEMI FRAMELESS GLASS (A/W AS 1926)
ACTUAL PANEL HEIGHTS TO BE DETERMINED BY ENGINEER BG - BALUSTRADE - FRAMELESS GLASS (BCA) PLD - PANEL LIFT DOOR
/ STRUCTURAL DESIGNER. BGSEMI - BALUSTRADE - SEMI FRAMELESS GLASS (BCA) PSC - PLYWOOD SHEET CLADDING
BL - BLOCKWORK MASONRY RN - RENDER
BSS - BALUSTRADE - STAINLESS STEEL CABLE RH - RAIN HEAD
ALUMINIUM FRAMED WINDOWS AND DOORS TO BE CLEAR BW - BRICKWORK RHS - RECTANGULAR HOLLOW SECTION 50 X 150MM
ANODIZED U.N.O. ALL FIXING & CLADDING DETAILS TO BE IN SB - HONED BLOCKWORK STACK BOND AX - SCYON AXON® CLADDING SYSTEM
STRICT ACCORDANCE WITH THE MANUFACTURERS DETAILS CBCO - COLORBOND® CUSTOM ORB LN - SCYON LINEA® CLADDING 150MM
AND SPECIFICATIONS. WINDOW SIZES SHOWN ARE NOMINAL CBKL - COLORBOND® KLIP LOK SS - STAINLESS STEEL
ONLY AND ARE TO BE VERIFIED ON SITE. CBTD - COLORBOND® TRIMDEK ST - SCYON STRIA® CLADDING SYSTEM
GLAZING TO BE IN ACCORDANCE WITH AS1288. CFC18 - COMPRESSED FIBRE CEMENT 15 / 18 / 24MM SMF - SHEETMETAL FLASHING
BUILDER TO CONFIRM SOFFIT HEIGHT DOES NOT CONFLICT CHS120 - CIRCULAR HOLLOW SECTION 120MM SHS90 - SQUARE HOLLOW SECTION 90MM
WITH WINDOW AND DOOR HEIGHTS.
CC AH CONC - OFF FORM CONCRETE FORMED IN SITU SHW - STAINED HARDWOOD BATTENS
CTP - CONCRETE TILT PANEL TO ENGS. SPECS. TOW - TOP OF WALL
FC6.0 - HARDIFLEX® FIBRE CEMENT SHEET CLADDING 6.0MM TPD - TILT PANEL DOOR. CONCEALED.
FG - FIXED GLAZING EXTERNAL CLADDING TO MATCH
FS - SELECTED FEATURE STONE ZSCCO - ZINCALUME SHEET CLADDING CUSTOM ORB
HWC150 - HARDWOOD COLUMN 150MM
01 02 03 PF ALUM - POOL FENCE - ALUMINIUM (A/W AS 1926)
PF GLASS - POOL FENCE - FRAMELESS GLASS (A/W AS 1926)
7,580 2,090 PF SFGLASS - POOL FENCE - SEMI FRAMELESS GLASS (A/W AS 1926)
7
PLD - PANEL LIFT DOOR
PSC - PLYWOOD SHEET CLADDING
01
RN - RENDER
RH - RAIN HEAD
RHS - RECTANGULAR HOLLOW SECTION 50 X 150MM
AX - SCYON AXON® CLADDING SYSTEM
LN EXISTING
- SCYON LINEA® CLADDING 150MM
2
SS - STAINLESS STEEL
ST - SCYON STRIA® CLADDING SYSTEM
1000 HIGH POWDER COATED ALUMINIUM
8-
SMF - SHEETMETAL FLASHING
BALUSTRADE - 50X5 ALUMINIUM PLATE TOP SHS90 - SQUARE HOLLOW SECTION 90MM
5° RAIL 50X5 ALUMINIUM PLATE BALUSTRADE SHW - STAINED HARDWOOD BATTENS
BOTTOM FIXED TO SUSPENDED SLAB TOW - TOP OF WALL
-0
AX TPD - TILT PANEL DOOR. CONCEALED.
AX AX EXTERNAL CLADDING TO MATCH
ZSCCO - ZINCALUME SHEET CLADDING CUSTOM ORB
AX
14
EXISTING UPPER FFL 18,180
ED
UPPER FFL 17,550
BL - AX
FS BL - RN
D EXISTING FFL 15,480
EN
LOWER FFL 14,800
CARPORT FFL 14,040
BL - RN FS
AM
FEATURE FREE FORM STONE
: ECO OUTDOOR "WAMBERAL" STONE
NORTH ELEVATION 1:100
2016 - 0730
SITE ADDRESS BUILDER CLIENT PROJECT DESCRIPTION ISSUE REVISION
SX Constructions S Tritton & P Loxton Proposed Additions WD D - 02
Lot 2 No 20 Mitti Street - Noosa Heads - STATUS : Issued For Building DRAWN : CH PROJECT NO
SHEET NO.
VBD 15 10
Approval
12 of 29
CECKED BY: CLH
© 2015 These drawings remain copyright of VOID Building Design and
04 3 1 5 14 4 8 3 / C HR IS @ V O ID B UIL D ING D E S IG N. C O M
GSPublisherEngine 1143.3.3.100
/ Q B C C L IC N O 13 17 6 10 may not be used in part or in whole without written consent by the author. DATE : 10/08/2017 PLOT DATE: 10/08/2017
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment 3 - Amended Building Approval.pdfRelated documentApplication case desk ↗
About this file
- File size
- 6.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.