Council archive · source document
Attachment 3 - Amended Building Approval · RAL20/0005
REFER ENGINEERS DOCUMENTATION FOR ALL FRAMING SIZES
REFER TRUSS MANUFACTURERS DOCUMENTATION FOR POINT LOADS
ALL BEARERS TO BE CONCEALED IN FLOOR CAVITY. (UNO) ALL JOIST TO BUTT JOIN INTO BEARERS. (UNO)
ENGINEERS DESIGN AND SPECIFICATION TO TAKE PRECEDENCE
CML - Concrete Masonry Lintel
PT LOAD - Point Load
LBW - Load Bearing Wall
TL - Denotes Timber Lintel To Eng. Specs
TL/GML - Timber Lintel/Galvanized Masonry Lintel LEGEND
CB - Concealed Beam To Eng. Specs. & Details
A B C D
BEARER - Floor Bearer To Engineers Specifications E FLOOR BEARER
DECK - Deck Bearer To Engineers Specifications
BEARER FLOOR JOIST
90 ROOF TRUSS
- Denotes 90SHS Post To Engineers Specifications
RAFTER
SUSPENDED CONCRETE SLAB OVER 250
TO ENGINEERS SPECIFICATIONS - Denotes 250x250 Dressed Hardwood Post To Engineers Specifications
ROOF BEAM
FLOOR JOISTS TO ENGINEERS
SPECIFICATIONS
7
360
60mm SLAB OVERHANG
03 03
01
TL
395 190 1,209 EXPOSED HOT DIPPED GALVANISED PFC'S
2,090
CANTILEVERED
TO ENGINEERS SPECIFICATIONS
BEARER
2
02 02
8-
TL 90 SHS 90 SHS PFC 90 SHS
CML
TL
TL
100 DIA HOT DIPPED GALVANISED CHS TO
ENGINEERS SPECIFICATIONS
TL
-0
PFC
TL
TL 90 SHS
PFC'S REQUIRE PACKING TO UNDERSIDE OF
90 SHS TL 90 SHS 90 SHS TL JOISTS - TO ENGINEERS SPECIFICATIONS
14
CML
TL
CML
TL TL HATCHED AREA DENOTES 60mm SET
7,580
TL
TL TL TL TL DOWN TO JOISTS FOR ENS/BATH
300 DEEP FLOOR
ED
JOISTS
90 SHS 90 SHS 90 SHS
CANTILEVERED
CANTILEVERED
CANTILEVERED
FLOOR JOISTS TO ENGINEERS
BEARER
BEARER
BEARER
SPECIFICATIONS
CML
D
TL
TL TL TL TL TL
EN
90 SHS 90 SHS 90 SHS 90 SHS
BEARER
01 01
SUSPENDED POOL OVER TO
AM
ENGINEERS SPECIFICATIONS CONCRETE MASONRY TO ENGINEERS
SPECIFICATIONS
CONCRETE MASONRY TO CANTILEVERED BEARERS TO
ENGINEERS SPECIFICATIONS ENGINEERS SPECIFICATIONS
3,975 7,110 7,690 6,090
A B C D E
2016 - 0730
FLOOR FRAMING PLAN 1:100
ENGINEERS DESIGN AND SPECIFICATION TO TAKE PRECEDENCE
SITE ADDRESS BUILDER CLIENT PROJECT DESCRIPTION ISSUE REVISION
SX Constructions S Tritton & P Loxton Proposed Additions WD D - 02
Lot 2 No 20 Mitti Street - Noosa Heads - STATUS : Issued For Building DRAWN : CH PROJECT NO
SHEET NO.
VBD 15 10
Approval
25 of 29
CECKED BY: CLH
© 2015 These drawings remain copyright of VOID Building Design and
04 3 1 5 14 4 8 3 / C HR IS @ V O ID B UIL D ING D E S IG N. C O M
GSPublisherEngine 1143.3.3.100
/ Q B C C L IC N O 13 17 6 10 may not be used in part or in whole without written consent by the author. DATE : 10/08/2017 PLOT DATE: 10/08/2017
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment 3 - Amended Building Approval.pdfRelated documentApplication case desk ↗
About this file
- File size
- 6.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.