[OCR of page images]
 

 

[GENERAL NOTES

NOTE: THE LANDSCAPE PLAN MUST BE READ IN CONJUNCTION
WITH THE OPERATIONAL WORKS LANDSCAPING DECISION NOTICE

 

PRELIMINARIES

e BEFORE WORK COMMENCES THE SUBCONTRACTOR IS TO
ORGANISE A PRE-START MEETING WITH THE LANDSCAPE
ARCHITECT TO ESTABLISH SCOPE OF WORKS, MANAGEMENT
PROCEDURES AND CLARIFY ANY ISSUES.

e@ WHERE ANY DISCREPANCIES OCCUR REFER TO LANDSCAPE
ARCHITECT.

e PRIOR TO COMMENCING CONSTRUCTION WORKS, VERIFY ALL
DIMENSIONS, LEVELS AND SITE SERVICES. REFER ARCHITECT’S
AND SURVEY DRAWINGS GENERALLY.

SITEWORKS

e INSTALL SILT CONTROL FENCING IN ACCORDANCE WITH N.S.C.
REQUIREMENTS.

e REMOVE ALL UNWANTED MATERIAL FROM LANDSCAPE
CONSTRUCTION AREA.

e AREAS TO BE CLEARED AND VEGETATION TO BE RETAINED ARE
TO BE CLARIFIED ON SITE BY LANDSCAPE ARCHITECT PRIOR TO
ANY CLEARING.

e WHERE BAD GROUND, UNSTABLE SOIL OCCURS OR LEVELS
PROVIDED ARE NOT FUNCTIONAL REFER TO L.A.

LEVELS

e EXCEPT WHERE INDICATED OR SPECIFIED, FINISHED SURFACE
LEVELS ARE TO BE FLUSH WITH ADJACENT SURFACE.

e GRADE EVENLY BETWEEN PRESCRIBED LEVELS AND FINISHED
SURFACE LEVELS.

e EXTERNAL LANDSCAPE LEVELS/ TREATMENT TO BUILDING
SURROUNDS TO COMPLY WITH BUILDING CODE OF AUSTRALIA
FOR TERMITE PROTECTION TO BUILDINGS.

CO-ORDINATE ESTABLISHMENT OF LEVELS WITH SUPERINTENDANT

DRAINAGE

e ALL FIELD INLETS AND SUB-SURFACE DRAINS TO BE CONNECTED
TO EXISTING DRAINAGE SYSTEM. REFER HYDRAULIC ENGINEERS
DRAWINGS FOR DRAINS AND HYDRAULIC SERVICES.

e ALL DRAINAGE REQUIREMENTS TO BE DETERMINED ON SITE BY BUILDER

e¢ SUB-SURFACE DRAIN TO BE 100mm MIN. AG -FLOW PIPE IN 10mm
DRAINAGE GRAVEL SURROUNDS.

e FIELD INLETS TO BE 200x200X450mm (OR AS SHOWN ON
DRAWINGS) PLASTIC SUMPS WITH L.D. GALV. STEEL SURFACE
GRATE. FINISH Min 25mm BELOW ADJACENT FINISHED LEVELS.

e ENSURE SITE DRAINAGE CAN OCCUR TO WHOLE OF SITE &
WHERE PATHS, EDGES, GARDENS ETC. MAY IMPEDE DRAINAGE,
REFER TO SUPERINTENDENT BEFORE CONTINUING WORKS.

e ENSURE DRAINAGE WORKS CORRELATE WITH ADJACENT LAND.

NEW GARDENS

e@ CULTIVATE GROUND TO A DEPTH OF 150mm.

e SPREAD ORGANIC SOIL MIX (AS 4419) OR EQUIVALENT TOA
DEPTH OF 300mm OVER PREPARED GARDEN AREAS.

e CROWN BEDS AT CENTRE TO MAX 300mm HIGH WHERE NOT
SHOWN ON DRAWINGS AS MOUNDED BEDS.

e MULCH GARDENS WITH FOREST BLEND TO A DEPTH OF 100mm.

PLANTING FOR EXGROUND TREES AND PALMS

e ALL TREES/PALMS TO COMPLY WITH SPECS SET OUT IN ‘NATSPEC
2 GUIDE, PURCHASING LANDSCAPE TREES, 1997.’

e LANDSCAPE CONTRACTOR TO PEG TREE/PALM POSITIONS FOR
APPROVAL BY LANDSCAPE ARCHITECT BEFORE EXCAVATION.

e FILL WITH APPROVED FREE DRAINING SITE SOIL TO 300mm FROM
FINISHED GARDEN LEVELS

e FILL BALANCE WITH IMPORTED ORGANIC SOIL MIX (AS 4419) OR
EQUIVALENT AND CROWN BED AT CENTRE.

e@ MULCH GARDENS WITH 25mm HOOP MULCH TO A DEPTH OF 75mm
AND AMIN. 800mm DIAMETER COLLAR.

GENERAL PLANTING

e@ SUPPLY AND PLACE PLANTS ACCORDING TO PLANT SCHEDULE
AND LOCATION ON DRAWINGS.

e WHERE DISCREPENCIES OCCUR ADVISE SUPERINTENDANT PRIOR
TO PLANTING.

e ENSURE PLANTS ARE PLACED AND PLANTED AT EQUAL CENTRES.

e ALL TREES MUST BE PLANTED A MIN. OF 1000mm FROM
UNDERGROUND SERVICES. LOCATION OF SERVICES TO BE
CONFIRMED ON SITE BY CONTRACTOR BEFORE EXCAVATION
COMMENCES.

e USE ONE AGRIFORM 10g FERTILI ZER (N.P.K. 20 -4.3-4.1) TABLET AT
ARATE OF 1/140mm, 2/200mm, 3/300, 4/45 litre AND ABOVE POT
SIZES.

e WHERE SPECIFIED USE THREE 1800X38X50mm HW STAKES & TIE
WITH HESSIAN.

e@ CULTIVATE SUBGRADE TO 150mm.

e SOAK PLANTS THOROUGHLY BEFORE REMOVING FROM
CONTAINER.

e REMOVE CAREFULLY & INSPECT ROOTBALL, REMOVE OLD

MATTED & COILED ROOTS TO EXPOSE YOUNG ROOTS.

DO NOT MIX SOIL FROM HOLE WITH MULCH.

ROUGHLY SQUARE HOLE SIDES.

FILL HOLE WITH WATER, ALLOW TO DRAIN BEFORE PLANTING.

FILL SOIL TO BE MIXED EVENLY TO MANUFACTURERS

RECOMMENDATIONS WITH WATER RETENTION GEL. (APPROX. 1

TEASPOON PER HOLE)

NEW TURFED AREAS

e@ SUPPLY AND SPREAD SANDY LOAM TOPSOIL (TO AS 2223) TOA
MINIMUM DEPTH OF 100mm. FILL DEPRESSIONS AND PROVIDE
EVEN FALLS AS INDICATED ON DRAWING.

e@ SUPPLY AND LAY 'A' GRADE GREEN COUCH AS INDICATED ON THE
DRAWINGS.

e WATER TURF IN WELL

e APPLY WATER TO MAINTAIN SOIL MOISTURE UNTIL ESTABLISHED.

EDGES
e SUPPLY AND LAY GARDEN EDGES AS SHOWN ON THE DRAWINGS.
REFER TO DETAIL.

PAVER STEPPERS

e SUPPLY AND INSTALL PAVER STEPPERS AS SHOWN ON PLANS.
BED ON A 100mm THICK CONCRETE BASE ON COMPACTED
SUBGRADE. SETOUT TO BE COORDINATED ON SITE. FINISH TO BE
SELECTED TO COMPEMENT ARCHITECTURAL FINISHES.

GRAVEL

e@ SUPPLY AND INSTALL DECORATIVE GRAVEL TO AREAS AS SHOWN
ON PLANS. GRAVEL TO BE SELECTED TO COMPLEMENT
ARCHITECTURAL FINISHES.

CONCRETE PAVEMENTS AND FOOTPATHS

e@ ALIGNMENT FOR FOOTPATHS TO BE PEGGED BY CONTRACTOR
AND APPROVED BY N.S.C. INSPECTOR PRIOR TO POURING

e@ ALL CONCRETE PATHS TO BE PLAIN BROOM F INISHED CONCRETE
TON.S.C, SPECIFICATIONS AND REQUIREMENTS.

e@ ALL FOOTPATHS TO COMPLY WITH (AS 1428)

e@ SETOUT AND LOCATIONS OF EXPANSION JOINTS AND CONTROL

MAINTENANCE

e@ MAINTAIN WHOLE OF LANDSCAPE WORKS FOR ESTABLISHMENT
PERIOD OF TWELVE (12) WEEKS FROM DATE OF PRACTICAL
COMPLETION OF LANDSCAPE WORKS.

MAINTENANCE TASK FRE QUENCY

e WATER - DURING EP PERIOD WATER EVERY SECOND OR THIRD
DAY TO MAINTAIN SOIL MOISTURE;ONCE WEEKL Y DURING MP TO
MAINTAIN SOIL MOISTURE.

e MOWING- ONCE WEEKLY TO HEIGHT OF 30MM.

e TRIMMING-CARRY OUT TRIMMING OF GRASS AGAINST PATHS,
SLABS, MOWING EDGES, BUILDINGS AND KERBS AS PART OF
MOWING PROGRAM.

e TOP DRESSING-WHEN TURF AREAS HAVE BECOME ESTABLISHED
AND IMMEDIATELY AFTER THE FIRST CUT, TOP DRESS THE LAWN
WITH 10MM LAYER OF PIT SAND OR APPROVED SCREENED
TOPSOIL. SCREED TOP DRESSING LAYER INTO LAWN TO GIVE AN
EVEN LAYER OVER THE ENTIRE AREA. ENSURE FALLS AND
LEVELS ARE EVEN AND ADJUST LEVELS WHERE NECESSARY TO
ACHIEVE PREVIOUSLY SPECIFIED FINISHED LEVELS.

e FERTILISE- AS REQUIRED WHERE PLANTS ARE NOT RESPONDING
TO SLOW RELEASE FERTILISER APPLIED AT PLANTING. ENSURE
THAT CORRECT FERTILISER IS USED FOR DIFFERENT PLANT
TYPES.

e WEEDING - AS REQUIRED TO PREVENT WEED COMPETITION AND
SEEDING.

e REMULCHING- AS REQUIRED TO MAINTAIN CONSISTENT DEPTH.

e PRUNING (FORMATIVE)- SHRUBS & VINES
(<200MM POT): COMMENCE 3 WEEKS AFTER
PLANTING, TIP PRUNE TO ENCOURAGE BUSHY
HABIT (>200MM POT): COMMENCE 6 WEEKS AFTER
PLANTING.

e MONITORING - PROVIDE LIST OF ACTIVITIES
COMPLETED AT MONTHLY INTERVALS.

IRRIGATION

PRELIMINARIES

e@ SUPPLY AND INSTALL A NEW:

e AUTOMATIC (CONTROLLER) IRRIGATION SYSTEM TO PLANTING
AREAS PLANTERS AND TURFED AREAS.

e LIASE WITH RELEVANT AUTHORITIES AND OBTAIN ANY APPROVAL
AS REQUIRED.

e COMPLY WITH GOVERNMENT STANDARDS AND CO-ORDINATE
WITH OTHER TRADES.

e CHECK LOCATIONS OF PENETRATION/CONDUITS AND INSTALL
WHERE REQUIRED.

e CONTRACTOR TO PROVIDE QUALIFICATIONS AND INSURANCES
BEFORE COMMENCEMENT OF WORK

PROVIDE:

e@ TWELVE MONTH GUARANTEE, MAINTAIN AGAINST FAULTY
WORKMANSHIP AND MATE RIALS FOR ESTABLISHMENT PERIOD
FROM DATE OF PRACTICAL COMPLETION.

e FOR PRACTICAL COMPLE TION ENSURE WHOLE SY STEM IS
OPERATIONAL.

e@ PROVIDE ‘AS BUILT’ DWG. WHEN APPLYING FOR PRACTICAL
COMPLETION. DRAWING TO CLEARLY SHOW MAIN LINE RUNS AND
SIZES, VALVE TYPES, SPRINKLER AND CONTROLLER LOCATIONS.

SYSTEM REQUIREMENTS

¢ IRRIGATION ZONES TO BE CO-ORDINATED ON SITE WITH
SUPERINTENDANT TO SUIT PROPERTY TITLES AND ASSOCIATED
WATER METERING CONFIGURATION.

¢ INSTALL REDUCED PRESSURE ZONE VALVES (N. S.C. APPROVED)
IN LINE, DOWN -STREAM OF TAKE OFF FROM MAIN SERVICE LINE.
COORDINATE LOCATIONS WITH SUPERINTENDANT ON SITE.

¢ ALL MAINS AND ANY PRESSURISED BRANCH TO THE MAINS TO BE
CLASS 12 PVC PIPE.

¢ ALLLINES IN GARDEN TO BE LDPE (LOW-DENSITY
POLYETHYLENE).

¢ CONTROLLER TO BE HUNTER OR EQUAL APPROVE D
(COMMERCIAL-ICC)

© CONTROLLER WIRING TO BE IN ACCORDANCE WITH AS3000 FOR
LOW VOLTAGE WIRING, COMPLETE RUN LENGTHS WHERE
POSSIBLE WITH ALL CONNECTIONS VALVE BOXED.

¢ INSTALL HUNTER SRV (OR EQUAL APPROVED) SOLENOID VALVES
WITH FLOW CONTROL.

¢ CONTROL VALVES TO BE HOUSED IN LOCKABLE HEAVY DUTY
PLASTIC VALVE BOXES WITH ACCESS FOR HAND MAINTENANCE.
LOCATE IN GARDENS WHERE POSSIBLE OR AS APPROVED WITH
SUPERINTENDANT.

¢ MAINS WATER SUPPLY CONNECTION POINT TO BE PROVIDED BY
BUILDER. CO-ORDINATE SUITABLE TAKE -OFF POINTS FOR
GARDENS AND PLANTERS ON SITE WITH SUPERINTENDENT.

¢ SUPPLY AND INSTALLATION OF A 240 VOLT AC GPO ON
DEDICATED CIRCUIT FOR IRRIGATION CONTROLLER TO BE

TURF AREAS

e TURF SPRINKLERS TO BE 100MM HUNTER (PGM OR PGP) POPUP
(OR EQUAL APPROVED) FITTED TO ARTICULATED SWING JOINT
TYPE RISER.

GARDEN AREAS -POPUPS

e INSTALL 300MM HUNTER SRS POPUPS TO GARDENS ON
ARTICULATED SWING JOINT TYPE RISER. INSTALL HUNTER SRS
SHRUB HEADS ON 800MM RIGID RISERS TO INTERNAL GARDEN
AREAS.

 

 

NOOSA COUNCIL
APPROVED PLANS

MCU13/0211, REC13/0136 & OPW13/0862

10 FEB 2014

 

 

PLANT SCHEDULE - Hilton Terrace Noosaville

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYMBOL BOTANICAL NAME POT SIZE TOTAL MIN MIN STAKED
QNTY. HEIGHT WIDTH
TREES
BAN int BANKSIA integrifolia 45 Litre 10 1.80M 0.80M
CUP ana CUPANIOPSIS anarcardioiodes 45 Litre 7 1.80M 0.80M
ELA ret ELAEOCARPUS reticulatus 45 Litre 3 1.80M 0.80M
MEL qui MELALEUCA quinquenervia 75 Litre 2 1.80M 0.80M *
SYZtie SYZYGIUM tierneyanum 100 Litre 8 2.20M 1.40M *
PALMS AND FEATURES
COR rub CORDYLINE fruticosa rubra 200mm 59 0.40M 0.30M
ALP aru |ALPINIA arundelliana 140mm 112 | 0.30M 0.15M
ALP mod |ALPINIA modesta 140mm. 91 0.30M 0.15M
ARC cun (M) |ARCHONTOPHOENIX cunninghamiana As supplied] 14 2.40M nla *
PAN ped PANDANAS pedunculatus (multi-stem) IAS supplied 3 2.50M 2.50M
ARC cun (S) |ARCHONTOPHOENIX cunninghamiana As supplied} 11 1.80M nla
ARC cun (T) IARCHONTOPHOENIX cunninghamiana ‘As Supplied) 9 3.20M na
CYA coo CYATHEA coopenii 45 Litre 4 1.20M 1.00M
LIC ran LICUALA ramsayi 25 Litre 1 1.00M 1.00M
SHRUBS
ACM smi |ACMENA smithii 200mm 4 0.20M 0.20M
ASP aus ASPLENIUM australasicum 200mm 26 | 0.30M 0.60M
BAE lap BAECKEA''La Petite’ 200mm 5 0.20M 0.20M
BAN rob BANKSIA robur 200mm 19 0.40M 0.40M
BAN spi BANKSIA spinulosa 200mm 1 0.40M 0.40M
COD var CODIAEUN variegatum 200mm 10 0.50M 0.50M
‘CRI ped CRINUM pedunculatum 200mm 24 0.60M 0.40M
MEL cla MELALEUCA ‘Claret Tops’ 200mm 73 0.40M 0.40M
PHI sel PHILODENDRON selloum 300mm. 3 0.80M 0.80M
PHI xan PHILODENDORON ‘Xanadu! 200mm 52 0.30M 0.30M
SPA sen SPATHIPHYLLUM sensation 200mm 10 0.30M 0.30M
SYZ aus SYZYGIUM australe 300mm 36 0.70M 0.50M
SYZlue SYZYGIUM luehmannii 300mm 12 0.70M 0.50M
SYZ bus SYZYGIUM australe 'Bush Christmas’ 200mm 83 0.40M 0.30M
SYZ cas SYZYGIUM cascade 200mm 29 0.40M 0.40M
SYZ eli SYZYGIUM australe ‘elite’ 300mm: 20 0.70M 0.50M
SYZ pan SYZYGIUM paniculata 300mm 38 0.70M 0.50M
XAN chr XANTHOSTEMON chryanthus ‘Fairhill Gold’ | 300mm 4 0.70M 0.50M
GROUNDCOVERS/TUFTY/CLIMBERS
ANI big |ANIGOZANTHOS 'big red’ 140mm 37 0.30M 0.15M
CAL dub CALOCHAENA dubia 140mm 78 0.30M 0.15M
CAR app. CAREX appressa 140mm. 36 0.30M 0.15M
DIA bre DIANELLA breviendunculata 140mm. 242 =| 0.30M 0.15M
DIA lit DIANELLA little jess’ 140mm. 265 | 0.30M 0.15M
HIB sca HIBBERTIA scandens 140mm. 19 0.30M 0.15M
HYM spe HYMENOCALLIS speciosa 140mm 95 0.30M 0.15M
LIR eve LIRIOPE muscari ‘Evergreen Giant’ 140mm 52 0.30M 0.15M
LOM con LOMANDRA confertifolia 140mm 39 0.30M 0.15M
LOM fil LOMANDRA filiformis 'mondra’ 125mm 82 0.15M 0.15M
LOM hys LOMANDRA hystrix 140mm. 75 0.30M 0.15M
VIO hed VIOLA hederacea 140mm. 169 | 0.15M 0.15M
TREES TO BE TRANSPLANTED ON SITE
PAN ped [PANDANAS pedunculatus Lexgd [1 [ wa | na |

 

Note: Pandanas to be certified free of parasites by suitably qualified horticulturalist

FLEXIBLE JOINING MATERIAL
AS SUPPLIED
COBBLESTONE PAVER TO BE:

ORGANIC MULCH AS

SELECTED
SPECIFIED——

FINISH FLUSH WITH TOP OF GARDEN

EDGE | 1h

GARDEN SOIL AS SPECIFIED

(03 \ COBBLES
\LDO1 ,

Typical Detail

 

PRAM RAMP TON.S.C.
SPECIFICATION

 

 

 

TONE GARDEN EDGE
|

     
    

 

ALLOW TO FERTILISE,
WEED AND TOPSOIL

EXISTING TURFED AREAS.
REPAIR ANY DAMAGE.

 

 

 

 

NEW 1500mm WIDE
CONCRETE FOOTPATH

 

 

 

iY

x

QY \
[a |
COMPACTED SUBGRADE

COBBLESTONE PAVER TO BE

FLEXIBLE JOINING MATERIAL
AS SUPPLIED a
CONCRETE BED =

COMPACTED SUBGRADE-

SELECTED

Longitudinal Section

 

 

 

 

SOIL AS SPECIFIED. FINISH
25mm BELOW TOP OF EDGE
TO ALLOW FOR TURF

VXIWATIAIVALVAIVALXIVXIX=-—TURF AS SPECIFIED.

| ——TOPSOIL AS SPECIFIED

2

FORM TO SUIT FINISHES
LEVEL AND CONTOURS.

 

 

COBBLESTONE EDGING TO BE SUPPLIED BY STONE
SUPPLIER IN FLEXIBLE, READY TO LAY LENGTHS.
RECOMMENDED SUPPLIER: NEOROX

FINISH TO COMPLEMENT ARCHITECTURAL FINISHES

SET OUT EDGE WITH SMOOTH CONTINUOUS LINES,
BOTH IN THE HORIZONTAL AND VERTICAL PLANES.

UNLESS OTHERWISE SHOWN AND/OR SPECIFIED
ABUT EDGE FLUSH WITH FINISHED SURFACES
WITH A ROLLED/GRADUAL CHANGE OF ANGLES.

DO NOT ABUT AN ACUTE ANGLE.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01 \

? STAKES AS SPECIFIED

Tr

a
\S5
%

PLANT TIES

 

 

 

 

 

 

 

 

 

 

 

 

 

Ss<cex (JUTE OR SIMILAR,
me: APPROVED PRODUCT,
DOUBLE 'FIGURE 8’)
§ Y 7
pS
“ae
FORM SHALLOW SAUCER
SHAPED DEPRESSION
2x IPotdia AROUND BASE OF PLANT
| yPot|| dia.
ORGANIC MULCH
AS SPECIFIED
KEEP min 50mm
CLEAR OF PLANT STEM
GARDEN SOIL AS SPECIFIED
t MY | As
oem ay
x < MESSY
Z
SSP ISOS

LOCATION OF NOMINATED
CONTROLLED RELEASE
FERTILISER

‘SUBGRADE

CULTIVATE SUBGRADE

 

 

ENSURE CROWN OF ROOTBALL LEVEL IS SET HIGHER
THAN ADJACENT FINISHED GROUND LEVELS TO
PREVENT EXCESSIVE PONDING AROUND ROOTBALL

 

 

SMALL TREE PLANTING N.T.S.

 

.LDO1

1200

600

/ 02

LDO1 /
aes

 

 

 

 

Typical Section

TREES

    
    
  

SINGLE STRAND OF 4 mm WIRE FASTENED —
100mm BELOW TOP OF POST WITH —s</

FLUORESCENT FLAGGING TIED AT 300 CENTRES _/ 1800 max. PICKET SPACING

|—<t— CAPPED STAR PICKETS PAINTED veuow/ \. FENCE TO EDGE OF DRIPLINE

 

GROUND LINE

NOTE

1. NO INGRESS OR WORKS ALLOWED WITHIN DRIPLINE PROTECTION ZONE.

2. NO WORKS (INCLUDING CUTTING OR FILLING) ARE ALLOWED WITHIN 2 METRES OF
THE DRIPLINE PROTECTION ZONE.

3. TREE PROTECTION MEASURES ARE TO BE IMPLEMENTED BEFORE THE
COMMENCEMENT OF ANY SITE WORKS. THEIR CONDITION AND EFFECTIVENESS ARE
TO BE MONITORED AND MAINTAINED BY THE CONTRACTOR WORKS SUPERVISOR.

4, WHERE CONCRETE MIXING, FUEL STORAGE OR ACTIVITIES THAT MAY ADVERSELY
AFFECT THE HEALTH OF VEGETATION TO BE RETAINED, FIX TO STAR PICKETS 900
HIGH CORREGATED GALVANISED STEEL SHEETING BURIED 150 mm INTO GROUND

TREE PROTECTION NS.
Typical Detail

Project

«Project. __——_—
‘EXISTING oe ——

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENSURE SMOOTH
CONNECTION TO
EXISTING FOOTPATH

 

 

 

 

 

 

 

 

 

 

 

NEW 20008%n WIDE

 

 

 

NEW 2000mm WIDE
CONCRETE FOOTPATH

 

 

 

 

 

‘04 \ NEW FOO

TTPATH LOCATION PLAN

 

HILTON TCE

 

Lf. CONCRETE FOOTPATH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JOINTS TO BE CO-ORDINATED ON SITE WITH SUPERINTENDENT. .L001// Typical Plan
i 1 E 30.06.06 |OP WKS AMENDMENTS| CD TH TITLE: FILE No. S0511458 b l

Client Project = o” [iranor fori nsnoues oo” [7H ELE Ne. S051) anembo_ consultants

NC Oliver Pro perties Pty Ltd TO koriki c | 07.12.05 |oPERATIONAL works] CD | TH SHEET 2 OF 2 landscape architecture recreation planning
H1 1 ton Terrace environmental management flora and fauna survey
Noosa : 71 1 e B | 03.12.05 |OPERATIONAL WORKS] CD | TH LANDSCAPE SCALE @ A1 anembo consultants pty.Itd. A.BN. 75 089473156

VI Sunshine Coast: | POBox 24 Moffat Beach QLD 4551

A | 29.11.05 FOR REVIEW CD | TH This document isthe copyright of anembo constants & GENERAL NOTES _§|/assnown Ph. 07 5437 0000 ox one or ax: a 5437 0088
ISSUER DATE DESCRIPTION [DRWNCKD|issue] DATE | DESCRIPTION [DRWN|CKD aad coer io te cevsopnent en the te weed & DETAILS DATE: NOVEMBER 2005 | e-mail: [email protected]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Used in these records

About this file

File size
11.2 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

APPROVED PLANS - MCU13_0211, REC13_0136 & OPW13_0862.pdf · 11.2 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.