1m timber balustrade wall with Colorbond Custom Orb roof 60/600/60 fire separation wall. Timber frame truss roof to Eng. Timber framed ceiling/bulkheads
selected timber top capping. Painted sheeting 'Surfmist' detail and installed to man. spec with square set plaster board
sheeting.
Colorbond half round gutters & Roof insulation achieve the Min.
Colorbond fascias 'Surfmist' 'R' rating in accordance with
NCC 2019 Vol. Two
Colorbond half round gutters &
Colorbond fascias 'Surfmist'
° 20.0 www.zestbuildingdesign.com.au
2 0.0 °
8m HEIGHT LIMIT
BOUNDARY
BOUNDARY
3638
10.0°
UNIT 2 - CEILING
RL 46.050 m
2700
3976
BED 4 BED 3 Concrete block retaining wall to be in
4240 accordance with structural engineers
Timber post to ENG. spec. painted design and detail. Provide
UNIT 1 - LVL 2 TOW. 44.550 m
waterproofing system to back of wall
RL 44.500 m BALCONY with ag drain and free draining backfill.
UNIT 1 - CEILING
RL 44.200 m
1 0.7 ° UNIT 1 TOW. 42.950 m
UNIT 2 - LVL 2
RL 43.500 m
3077
KITCHEN ALFRESCO
2700
Concrete
UNIT 2
stairs to detail
1000
ALFRESCO BED 4 BATH
UNIT 1 - LEVEL 1
RL 41.500 m
TOW. 40.077 m
TOW. 39.744 m
1200
Garage Level
RL 40.500 m
NGL COMPACT FILL
Cut and fill ratios and grade to
Civil ENG. detail
Concrete block retaining wall to be in Suspended timber floor to Footings and slab construction shall to be in accordance with engineers design Swimming pool to be in accordance with engineers design
accordance with structural engineers ENG. details and detail and ncc 3.2. Slab on ground is to be monolithic to be in accordance and detail. All pool and spa construction to be in accordance
design and detail. Provide waterproofing with engineers design and detail and as 2870. Termite barriers to comply with with manufacturers/installers specifications. Pool to have
system to back of wall with ag drain and as 3660.1 and ncc 3.1.3. approved 'kordon' termite barriers are required to suitable pumps in accordance with manufacturers/installers
free draining backfill. perimeter and penetrations of slab to be designed and installed by specialist specifications. Provide pool fence to be in accordance with
approved contractor - guarantees are required by the owner from the NCC 3.9.3, the Building Act 1993, Building Regulation 2006,
manufacturer / installer of the termite barriers. Provide moisture barrier (200um) AS 1926 . Pool fence to be min. 1200mm high above
under slab with 200mm laps. securely tape joint adjoining finished surface level and have 900mm non climbing
zone as specified in pool legislation
1 Section
A.100 Section 3 1 : 75
1m timber balustrade wall with Colorbond Custom Orb roof 60/600/60 fire separation wall. Timber frame truss roof to Eng. Roof insulation achieve the Min.
selected timber top capping. Painted sheeting 'Surfmist' detail and installed to man. spec 'R' rating in accordance with Disclaimer: Zest Building Design Pty. Ltd. retains all
NCC 2019 Vol. Two common law, statutory law and other rights including
copyright and intellectual property rights in respect of this
Colorbond half round gutters & Timber framed ceiling/bulkheads with document.
Colorbond fascias 'Surfmist' square set plaster board sheeting.
The recipient indemnifies Zest Building Design Pty. Ltd.
against all claims resulting from use of this document for
any purpose other than its intended use, unauthorized
changes or reuse of the document on other projects without
the permission of Zest Building Design Pty. Ltd.
Colorbond half round gutters & Under no circumstance shall transfer of this document be
Colorbond fascias 'Surfmist' deemed a sale or constitute a transfer of the license to use
° this document.
2 0.0
BOUNDARY
20.0
°
Revisions
8m HEIGHT LIMIT
BOUNDARY
A 31/01/2023 COUNCIL RFI TW
5386
UNIT 2 - CEILING
RL 46.050 m
5157
ENS BED 1 BALCONY
3500
TOW. 44.550 m
TOW. 44.550 m BALCONY BED 2 BED 3 1m timber balustrade wall with
2550
selected timber top capping. Painted
3386
UNIT 2 - LVL 2
RL 43.500 m
Timber post to ENG. spec.
painted
5948 COMPACT FILL UNIT 2 UNIT 1 TOW. 41.950 m
Status
4986
3000
2700
Timber post to ENG. GARAGE GARAGE
spec. painted
UNIT 1 - LEVEL 1 PERMIT ISSUE
RL 41.500 m
TOW. 40.430 m Client
4349 1000
Garage Level
RL 40.500 m
IZAROX QLD PTY LTD
TOW. 39.744 m
2182
Project
NGL Cut and fill ratios and grade to
Brighton Springs
Civil ENG. detail
COMPACT FILL
73 SOUTHERNCROSS PRADE
SUNRISE BEACH, QLD 4567
Concrete block retaining wall to be in Suspended timber floor to Footings and slab construction shall to be in accordance with engineers design Concrete block retaining wall to be in Drawing
accordance with structural engineers ENG. details and detail and ncc 3.2. Slab on ground is to be monolithic to be in accordance accordance with structural engineers
design and detail. Provide waterproofing with engineers design and detail and as 2870. Termite barriers to comply with design and detail. Provide SECTIONS
system to back of wall with ag drain and as 3660.1 and ncc 3.1.3. approved 'kordon' termite barriers are required to waterproofing system to back of wall
free draining backfill. perimeter and penetrations of slab to be designed and installed by specialist with ag drain and free draining backfill.
approved contractor - guarantees are required by the owner from the
manufacturer / installer of the termite barriers. Provide moisture barrier (200um) Project No Date Author
under slab with 200mm laps. securely tape joint
2 Section 22004 31/01/2023 TW
A.100 Section 4 1 : 75
Scale: @ A1 Drawing No. Revision
1 : 75 A.301 A
24/04/2023 9:38:02 AM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - design plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 13.4 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.