Council archive · source document
Annexure A - existing development plans · OPW15/0072
Attached to the e-mail MCU15/0038 & OPW15/0072 Development Application.
Plans and drawings: the text below has words only, no drawings.
168 noosa parade, noosa heads FE N existing pandanus to remain CE ON TH remaining existing ground IS BO cover/garden beds to be removed UN DA RY TO 1x existing tree (unknown species) BE to be removed RE MO NOOSA PARADE VE D 6x fence height foliage to be removed with fence existing lilly pilly to be removed 5x existing palms to be removed existing garden bed to be removed EXISTING 2x existing palms to be removed existing pandanus to remain 3x existing palms to remain 5400 carpark existing hedge to be removed 2850 2850 6500 existing site plan concept drawings only not for construction PROPOSED: CLIENT: BUILDER: MANDY'S DESIGN & DRAFTING SHEET: 2 of 10 DATE: ISSUE NO: OFFICE LAYOUT DOWLING & NEYLAN TBC PH: 0403 481 474 SCALE: 1:200 APRIL 15 H NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 3 pages
Page 2
168 noosa parade, noosa heads
17440
2715 2655 2720 5220 4130
200
200 2510 2110 200 3930 200
05 of 10
(south-west)
elevation D
05 of 10
elevation C
(north-west)
200
600
200
2220
office 5 wc
2810
500
(carpet)
200
(tiles)
600
3520
3920
kitchen
200
(tiles)
deck 1 office 4
2810
1110
2710
(carpet)
200
200
200
200
UP
100
1000
10600
10600
4260
1070
1530
200
3330
deck 2
2650
2450
100
carpark
100
5480
200
200
4080
100
4000
office 2 office 1 entry/reception
3540
1580
1850
2920
2520
(tiles) (tiles) (tiles)
office 3
100
(tiles)
store
200
840
200
600
200
200
200
200
2680
courtyard
2080
2080
elevation A
elevation B (north-east)
(south-east)
05 of 10
04 of 10 -ENTRY/RECEPTION TO BE RELOCATED
existing ground floor
-WC TO BE RECONFIGURED BUT STILL COMPLY
-RECONFIGURE SOME OFFICE AREAS
-COURTYARD TO BE REMOVED AND PERGOLA TO BE REPAIRED AND RECTIFIED
100 100 200
200 3665 200 940 1420 450 2240
200
200 3175 100 390 100 4150 2575 200 5150 200
6040 7120 3280
8315 8125
concept drawings only
not for construction
PROPOSED: CLIENT: BUILDER: MANDY'S DESIGN & DRAFTING SHEET: 3 of 10 DATE: ISSUE NO:
PH: 0403 481 474 SCALE: 1:100 APRIL 15 H
OFFICE LAYOUT DOWLING & NEYLAN TBC
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
Page 3
168 noosa parade, noosa heads 8115
05 of 10
(south-west)
elevation D
100 100 100 100
05 of 10 100 1185 1270 925 2070 2075 100
elevation C
(north-west)
100
100
100
shr wc
920
store
(tiles) (tiles)
store
460
l'dry
100
(tiles)
3180
(carpet)
2220
4710
line of lower floor
DN
3690
store
100
100
kitchen
1430
(tiles)
100
100
100
4080
office 1
2610
office 2 (timber)
(carpet)
200
200
100 100 200
100 1645 810 1000 100 4070
elevation A 100 3655 100
elevation B (north-east)
(south-east)
100 2590 100 5135 200
05 of 10
04 of 10
TIMBER CLADDING FEATURE AS PER PROPOSED
PLAN REQUIRED TO ENHANCE ELEVATION
existing upper floor
concept drawings only elevation A (south-east) ALL GLASS BRICK WINDOWS TO BE REMOVED AND
not for construction REPLACED WITH FIXED GLASS TO MODERISE
PROPOSED: CLIENT: BUILDER: MANDY'S DESIGN & DRAFTING SHEET: 4 of 10 DATE: ISSUE NO:
OFFICE LAYOUT DOWLING & NEYLAN TBC PH: 0403 481 474 SCALE: 1:100 APRIL 15 H
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
Page 4
168 noosa parade, noosa heads
UPPER FLOOR TOP PLATE
UPPER FLOOR JOINERY LINE
2580
2100
UPPER FLOOR
GROUND FLOOR TOP PLATE
GROUND FLOOR JOINERY LINE
2400
2100
GROUND FLOOR
200
PAD LEVEL
elevation B (north-east)
elevation C (north-west)
existing elevations
concept drawings only
not for construction elevation D (south-west)
PROPOSED: CLIENT: BUILDER: MANDY'S DESIGN & DRAFTING SHEET: 5 of 10 DATE: ISSUE NO:
PH: 0403 481 474 SCALE: 1:100 APRIL 15 H
OFFICE LAYOUT DOWLING & NEYLAN TBC
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
Used in these records
Annexure A - existing development plans.pdfRelated documentApplication case desk ↗
Annexure A - existing development plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 403 KB (small file)
- File type
No other editions are linked here.