Council archive · source document
20517 App Q.pdf [As Published] · 132007.1259
VISITOR ACCOMMODATION CODE Performance Criteria and Acceptable Solutions 4. spmm meanea company PROBABLE SOLUTIONS . SPECIFIC OUTCOMES (IF CODE ASSESSABLE) SOLUTIONS ore) SWE) NCIL USE ONLY Scale v 031 The proposed hostel has been designed to ensure building bulk Visitor hostels are at a scale and density No solution provided does not dominate the visual amenity of Peregian. compatible with surrounding land uses. Privacy v 032 $32.1 The proposed shared recreation areas are located in the interior of Visitor hostels are designed to ensure privacy for Outdoor sitting areas, common rooms and the proposed development. The design, combined with the limited occupants of the premises and adjoining residential | recreational facilities are located at least 10m from number of surrounding residential properties will resuit in limited uses through— the property boundary of adjoining land included in impacts for residential uses. (a} locating potentially noisy activity areas a residential zone; and (communal open space, kitchen, dining and facilities) internal to the development rather $32.2 v than on the perimeter of the premises; and Windows, doors and balconies are located so as The visitor accommodation buildings are space greater than twelve (b} avoiding overlooking of the windows or private | not to face windows, balconies or the private open (12} metres to avoid any privacy issues. The beach shacks have open space of adjoining properties. Space of adjoining residential premises which are been orientated to ensure that windows and private open space less then 12m away. areas do not overlook onto each other. Kitchen, bathroom and dining facilities v 033 All guests have access to bathrooms and kitchen facilities. All guests and staff have access to— No solution provided. (a) internal bathrooms and sanitary facilities; and (b} common kitchen and dining facilities. Kitchen and dining v 034 $34.1 A large communal kitchen has been provided for each set of four Kitchen and dining areas are large enough to Kitchen and dining areas are not less than 5% of (4) rooms provided. Recreation and dining space will therefore be accommodate all occupants and have adequate the hostel’s total gross floor area. ample, providing a quality, but affordable holiday accommodation. kitchen and dining facilities. Common rooms AS 035 $35.1 The proposed layout of the units incorporates a living room as part Acommon room, sufficient in size to accommodate | A common room with a minimum floor area of not of the each shared unit, which fulfils the requirement for providing 60% of occupants at any one time, is provided. less than 7% of the visitor hostel’s total gross floor guests with a common indoor recreation area. The development area is provided; and provides extensive outdoor recreation spaces for all guests to utilise. $35.2 v If the visitor hostel has a restaurant or café, itis of a The proposed layout of the units incorporates a living room as part 4 Solution: v = Acceptable Solution AVS = Alternative Solution N/A = Not applicable to this proposal 20517 - Essence of Peregian Appendix Q 20517_visitoraccommodationcode_FINAL_fw.doc Commenced 3” February 2006 - Updated October 2006 Page 10
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
20517 App Q.pdf [As Published]Related documentApplication case desk ↗
About this file
- File size
- 6.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.