Council archive · source document
20517 App Q.pdf [As Published] · 132007.1259
NATURAL HAZARDS OVERLAY CODE Performance Criteria and Acceptable Solutions PERFORMANCE CRITERIA Nee 8-18 ee COMMENTS 08 An adequate and accessible water supply is provided for fire fighting purposes. $8.1 For premises not in a water service area— each lot has an accessible dam, swimming pool or water tank with fire brigade fittings that contains at least 5000 litres per dwelling. NIA The subject site is located within the Peregian Water Supply Zone. Firebreaks and fire access tracks 09 Firebreaks or fire access tracks provide— a) adequate access for fire fighting and other emergency vehicles; and b) adequate width to minimise the risk of fire crossover. $9.1 Firebreaks are provided by— a) acleared road reserve not less than 20m wide located around the perimeter of the development; or b) fire access tracks between the development and surrounding vegetated lands that— i. are a minimum cleared width of 6m; ii, have a maximum grade of 12.5% (1:8); iii. have a formed pavement; iv. have access at each end and in other locations where necessary; v. have passing areas and turning areas; vi. have clearly identified access points for emergency vehicles; and vii. are located on public land or within access easements that are granted in favour of Noosa Shire Council and the Queensland Fire and Rescue Service.31 AIS The size and location of the proposed development does not warrant the inclusion of a fire trail along the western boundary. The threat of bushfire is from the south west of the site and access for fire fighting can be achieved from the existing unnamed road to the south of the site. This road is public land allowing access for Noosa Shire Council and the Queensland Fire and Rescue Service. General 010 The safety of people and property are maintained by avoiding increases in the number of people living, working or congregating in areas of high or medium $10.1 The proposed lots are not located on land that is subject to Medium or High Bushfire Hazard on overlay maps OM1.4-OM9.432; or NIA The proposal does not seek approval for reconfiguring a lot . 4 Solution: ¥ = Acceptable Solution AIS = Alternative Solution N/A = Not applicable to this proposal 20517 — Essence of Peregian Appendix Q 20517_naturalhazardsOverlayCode_FINAL_mrc.doc Page 4
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
20517 App Q.pdf [As Published]Related documentApplication case desk ↗
About this file
- File size
- 6.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.