Council archive · source document
08/0274 - Operational Works - Transport Type 5 - Jetty [As Published] · 142008.274
SECTION’ A)
” QT
JETTY USE:
SINGLE USER, PRIVATE
NO VEHICULAR ACCESS
WALKWAY DECK VERTICAL
DESIGN LIVE LOAD - 2.0 kPa
MAXIMUM MOORED VESSEL - 5m
BERTHING VELOCITY - 0.5 m/sec
3% HwOo
1775 xNot4 TYPE 17
st. STEEL
SCREWS @ 460 CRS
PILES:
@ 200 H6 MARINE HWD POLES
NOTE THAT ALL POLES TO COMPLY
WITH AS 2159 - PILING CODE
180 x 75 HWD
2M16SS
18) x76 HWO ————
DETAIL ( 3 \
NOTES:
4. UNLESS NOTED OTHERWISE ALL TIMBER SHALL BE
DURABILITY CLASS 1 OF APPROVED SPECIES AND HAVE
A STRESS GRADE OF F14 MIN.
2. UNLESS NOTED OTHERWISE ALL CONSTRUCTION SHALL
COMPLY WITH THE ENVIRONMENTAL PROTECTION AGENCYS'
OPERATIONAL POLICY - “BUILDING AND ENGINEERING
STANDARDS FOR TIDAL WORKS.”
3. ALL STAINLESS STEEL BOLTS, RODS, ETC., SHALL BE
APPROVED MARINE GRADE 316. ALL OTHER STEELWORK
INCLUDING NUTS, BOLTS, WASHERS, SCREWS, NAILS, ETC.,
SHALL BE HOT DIPPED GALVANISED OR STAINLESS STEEL.
4. TOP OF PILES SHALL BE SEALED AND FULLY CAP FLASHED
OR RINGED.
5. DIMENSIONS AND LEVELS SHALL NOT BE SCALED FROM
THE DRAWINGS.
| IN An 010 263 877
Structural | Civil Design Engineers
J. JETTER
PROPOSED JETTY
LOT 603
No.27
MASTHEAD QUAY
NOOSA WATERS
RABRINK PTY LTD T/A
John Norden
& Associates
Suite 16 Tewentin Plazes"
& Poinciana Avenue | PO Box 206
Tewartin Q 4086
=
Ph: 07 54407137 Fax 07 54407172
Emalt. [email protected]
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
08/0274 - Operational Works - Transport Type 5 - Jetty [As Published]Related documentApplication case desk ↗
About this file
- File size
- 793 KB (small file)
- File type
No other editions are linked here.