APPLICATION FOR A MINOR CHANGE TO A DEVELOPMENT APPROVAL
Author	Development Planner, Wilhelm Koschade
APPLICATION DETAILS
Application No.	132002.220270.5
Development Approval	Material Change of Use (Service Industry, Warehouse and Service Shops) and Reconfiguring a Lot (12 Lots)
Applicant	Angela Gamlin
Request Received On	27 June 2018

PROPERTY DETAILS
Property Address	4/40 Gateway Dr NOOSAVILLE  QLD  4566
RP Description	SP 294020
Land Area	No Land Area details available
Existing Use of Land	Industrial Business Type 1 & 2

STATUTORY DETAILS
SEQRP Designation	Urban Footprint
Locality	Noosaville Locality
Zone	Industrial Zone
Overlays	Nil
Assessment Type	Minor Change to Development Approval
PROPOSAL
The application seeks approval to change the existing development approval to permit an 80m2 caretakers residence to be constructed a mezzanine level within tenancy 4 at 40 Gateway Drive, Noosaville.
A locality and proposal plans of the development is provided below.

background
A Development Permit for Material Change of Use for Service Industry, Warehouse and Service Shops and Reconfiguring a Lot (12 Lots) was issued on 16 January 2003.  Subsequent representations were made to conditions of the approval and a Negotiated Decision Notice was issued on 10 April 2003.

At the time the original application was publicly notified, two properly made submissions were received.  The submitters were primarily concerned with the way in which public notification was carried out, a reduction in property valuations as a result of the development, amenity concerns and the removal of vegetation.

The approved plans indicate that subject site was to be developed into 6 tenancies, all for the purposes of service shop (total 360sqm) with the exception of one, which was to be for service industry (150sqm).  A total of 15 car parking spaces were proposed.

Changes to the approval were approved on 17 July 2003 and 31 January 2005. The development relating to the subject site was subsequently constructed.
On 10 August 2017, Council issued a Generally in Accordance approval relating to minor amendments to the building and carparking layout.
assessment
Instruments for Statutory Assessment
Under the Planning Act 2016 the application must be assessed against each of the following statutory planning instruments to the extent they are relevant to the development:
State Planning Policy;
South East Queensland Regional Plan;
Planning Regulation 2017;
The Noosa Plan.
The following codes from the Noosa Plan are applicable to this development:
Noosaville Locality Code
Business Uses Code
Engineering Works Code
Landscaping Code
Statutory Process
The applicant has requested to make a minor change to a development approval under s78 of the Planning Act 2016. An application for a minor change to a development approval can only be made in circumstances where a change would constitute a ‘minor change’.
The proposed change to the development approval requested by the applicant is determined to constitute a minor change on the grounds that:
the development would not result in substantially different development;
the change does not include prohibited development;
the change would not require the application to be referred to an additional referral agency or cause a referral agency to have regard to new mattes prescribed by regulation;
where the original application was code assessable, the change would not cause the application to become impact assessable.

Statutory Instruments – Planning Scheme
Car Parking
Currently the development has 18 car spaces available on the site. The proposed caretakers requires 1 additional space as it is proposed to be constructed as mezzanine level and does not result in any reduction in use area within tenancy 4.
The original development (Lot 12) was approved with the following layout and comprises a service shop x 4 and service industry x 2 uses. A 16m2 mezzanine has previously been development within one of the Service Industry tenancies and contributes to the total car parking calculation:

The car parking rate under the Superseded Planning Scheme for the approved use of Service Shop and Service Industry:-.

Service Industry 380sqm +16sqm – 1 per 50sqm = 4 spaces
Service Shop 300sqm – 1 per 30sqm = 10 spaces.

The proposed additional mezzanine to accommodate the caretaker’s residence triggers 1 additional car parking under this planning scheme.

Under the Noosa Plan, both uses are now defined as Type 2 Production, alteration, repackaging and repairing and applicable car parking rate is – 1 space per 30sqm or part thereof, for areas up to 150sqm; and 1 space per 50sqm or part thereof for areas up to 500sqm and 1 space per 100sqm or part thereof of use area in excess of 500m2.

Accordingly, based on a total site floor area of 696sqm, the car parking requirement including the mezzanine additions would be 13.96 (14) spaces.

The site has 18 car spaces available. The total triggered car parking rate is 15 spaces and therefore the caretakers raises no concern in this respect.

RECOMMENDATION
With regard to Application No. 132002.220270.5, to make a minor change to an existing approval for an Ancillary Dwelling Unit situated at Gateway Centre 40 Gateway Dr Noosaville Qld 4566 described as Lot 12  SP 294020, is provided in accordance with Section 63(5) of the Planning Act 2016, Council on 18/07/2018 decided to:
A.	Approve the change.
B.	Amend condition 1 to read as follows:
Development undertaken in accordance with this approval must generally comply with the approved plans of development.  The approved plans are numbered 1 to 15 prepared by Herwig Hartl, Site Plan Sheet 1 of 3 dated 27/9/10, Floor Plans – Sheet 2 of 3 dated 27/9/10 and Elevations and Section Details – Sheet 3 of 3 dated 27/9/10 prepared for GMS Corp Pty Ltd and the Ground Floor Plan (Unit 4, lot 12) of the Proposed Caretakers Plan, dated 18/07/2018.
C.	Include the following additional conditions:
80.	One car space must be made available exclusively for the use of the resident/s of the approved caretakers in Lot 12 and must be line marked accordingly.

[word/footer1.xml]
Page 5 of 5

[word/header1.xml]
3

[Attachment: image2.png (image text)]
 

 
 

Dining

Ling

a eEzZANWE Lever

 

    
 


[Attachment: image3.png (image text)]
SITE ANALYSIS
LOT
SERVICE
SERVICE
TOTAL
CARPARKS | SITE COVER
1632
270
S70
367%
360
660
680
400%
300
2036
500
790
20
400%
1669_} 300
18
400%
|
398%
1275
150
510
400%
4275
150
330
480
510
400%
[1275
150
480
510
14
400%
510
400%
400%
39 69 %
700
3997
te

[Attachment: image4.png (image text)]
 
   

(eo off} ee

 

FRONT ELEVATION

 

RIGHT ELEVATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEFT ELEVATION
LOT 12
LAND AREA 4751 SQM
SERVICE SHOPS AREA | 300 SQM Noosa sine: couNen.
SERVICE INDUSTRY AREA | 400 SOM PLANS APPROVED
TOTALAREA 700 aM

SIGNATURE:
SITE COVER 29.97% warns
CARPARKS REQUIRED | 18
CCARPARKS PROVIDED | 18

 

 

 

 

Used in these records

About this file

File size
1.4 MB (small file)
File type
DOCX

No other editions are linked here.

Original file

Log in to download the original file

Minor Change Report 132002.220270.5.docx · 1.4 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.