Landscaping Plans 578_240219_CG_LDP_ISU B RIVER HOUSES GYMPIE TERRACE NOOSAVILLE-PACKAGE · OPW23/0179

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
SCHEDULE OF FINISHES
NO.    ITEM                                       PRODUCT DESCRIPTION                FINISH                                                                           SUPPLIER                                                          NO.          ITEM                                              PRODUCT DESCRIPTION                               FINISH                                                                                                         SUPPLIER

PLANTERS                                                                                                                                                                                                                                 7.6         PLANTER TYPE 9.                                   PLANTER TYPE 9. (P9) PLANTER ON                   PLANTER DEPTH: 2500MM DEPTH. PLANTER FINISH LEVELS TO BE (MIN) 50MM SET DOWN                                    FYTOGREEN
                                                                                                                                                                                                                                                     (P9)                                              GROUND 2500MM . BUILDING                          FROM TOP OF ADJOINING PLANTER WALLS AND GLAZING FRAMES.                                                         1300 182 341
7.1    PLANTER TYPE 4.                            PLANTER TYPE 4. (P4)               PLANTER DEPTH: TYPICALLY 100MM FALLING TO 200MM DEPTH. ALL PLANTER FINISH SET    FYTOGREEN                                                                      INTENSIVE.                                        STRUCTURE CONTAINED.                                                                                                                                              CONTACT: MIKE HEARD
       CONTAINERISED INTENSIVE.                   CONTAINERISED PLANTER              DOWN FROM BUILDING AT REQUIRED HEIGHT AND HAVE ADEQUATE FALLS AWAY FROM          CONTACT OFFICE:                                                                                                                                                                    PLANTER PROFILE (TOP TO BOTTOM): 50MM DEPTH OF PREMIUM FINE CYPRESS MULCH                                       0417622228
       (P4).                                      100-200MM DEPTH. BUILDING          BUILDING. REFER TO ARCHITECTS AND ENGINEERS DRAWINGS FOR DETAIL.                 GEOFF HEARD                                                                                                                                                                        TO AS4454 SAMPLE MUST BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO INSTALL,
                                                  STRUCTURE CONTAINED.ON             **DEPTHS AND WEIGHTS TO BE APPROVED BY PROJECT ENGINEER**                        1300 182 341                                                                                                                                                                       (REMAINING DEPTH) HYDROCELL 40 PODIUM MIX AS DETAILED ABOVE, A24 GEOTEXTILE                                    MEDIA
                                                  BASEMENT SLAB.                                                                                                      CONTACT SITE: MIKE HEARD                                                                                                                                                           TO BASE AND MINIMUM 200MM UP WALLS AND 2.5MM CORFLUTE SHEET PROTECTION TO                                      NUGROW
                                                                                     PLANTER PROFILE (TOP TO BOTTOM): 50MM DEPTH PEBBLE MULCH 15MM NAMBUCCA           0417622228                                                                                                                                                                         WATERPROOFING MEMBRANE ON BASE AND WALLS UP TO FINISHED MEDIA LEVEL. (ANY                                      CONTACT: KANE HAUSER
                                                                                     PEBBLE MULCH TO AS4454 SAMPLE MUST BE APPROVED BY LANDSCAPE ARCHITECT                                                                                                                                                                                               FOOTINGS OR BASE STRUCTURES TO HAVE 20MM DRAINAGE CELL TO BASE)                                                PH: 3294 1586
                                                                                     PRIOR TO INSTALL, (REMAINING DEPTH) HYDROCELL 40 PODIUM MIX MOUNDED AS           MEDIA                                                                                                                                                                              WATERPROOFING MEMBRANE TO ARCHITECT'S SPECIFICATION. IRRIGATION: AUTOMATED
                                                                                     DETAILED ABOVE, A24 GEOTEXTILE TO BASE AND MINIMUM 200MM UP WALLS, 20MM          NUGROW                                                                                                                                                                             IRRIGATION SYSTEM CONNECTED TO WATER SUPPLY WITH CENTRAL CONTROLLER WITH
                                                                                     DRAINAGE CELL TO BASE AND 2.5MM CORFLUTE SHEET PROTECTION TO                     CONTACT: KANE HAUSER                                                                                                                                                               DAILY BACK TO BASE MONITORING. REFER TO PLANTER IRRIGATION ITEM DETAIL FOR ALL
                                                                                     WATERPROOFING MEMBRANE ON BASE AND WALLS UP TO FINISHED MEDIA LEVEL.             PH: 3294 1586                                                                                                                                                                      PLANTERS. DRAINAGE: FREE DRAINING (IF NOT ALL RAISED PLANTERS TO HAVE
                                                                                     WATERPROOFING MEMBRANE TO ARCHITECT'S SPECIFICATION. IRRIGATION: AUTOMATED                                                                                                                                                                                          DRAINAGE ALLOCATIONS WITHIN THE BUILDING STRUCTURE AT REGULAR INTERVALS TO
                                                                                     IRRIGATION SYSTEM CONNECTED TO WATER SUPPLY WITH CENTRAL CONTROLLER WITH                                                                                                                                                                                            HYDRAULIC ENGINEER'S SPECIFICATION). DRAINAGE SUMP OUTLETS TO HAVE SPS
                                                                                     DAILY BACK TO BASE MONITORING. REFER TO PLANTER IRRIGATION ITEM DETAIL FOR ALL                                                                                                                                                                                      TRUFLO 100MM WITH ALL-PURPOSE PLANTER BOX ADAPTOR, FITTED WITH SLOTTED
                                                                                     PLANTERS. DRAINAGE: ALL CONTAINERISED PLANTERS TO HAVE DRAINAGE                                                                                                                                                                                                     100MM PVC PIPE WITH SCREW ON CAP, PIPE SHOULD BE WRAPPED IN GEOFABRIC. REFER
                                                                                     ALLOCATIONS WITHIN THE BUILDING STRUCTURE AT REGULAR INTERVALS TO HYDRAULIC                                                                                                                                                                                         TO TYPICAL DETAILS FOR FURTHER DETAIL. FOR PLANT TYPES REFER SYMBOLS TO
                                                                                     ENGINEER'S SPECIFICATION. DRAINAGE SUMP OUTLETS TO HAVE SPS TRUFLO 100MM                                                                                                                                                                                            PLANTING SCHEDULE.
                                                                                     WITH ALL-PURPOSE PLANTER BOX ADAPTOR, FITTED WITH SLOTTED 100MM PVC PIPE                                                                           7.7          PLANTER TYPE 10.                                  PLANTER TYPE 10. (P10)                            PLANTER DEPTH: TYPICALLY 300MM DEPTH. ALL PLANTER FINISH LEVELS TO BE 50MM SET                                 FYTOGREEN
                                                                                     WITH SCREW ON CAP, PIPE SHOULD BE WRAPPED IN GEOFABRIC. REFER TO TYPICAL                                                                                        CONTAINERISED INTENSIVE.                          CONTAINERISED PLANTER 300MM                       DOWN FROM TOP OF ADJOINING PLANTER (BUILDING SILL) WALLS.                                                      CONTACT OFFICE:
                                                                                     DETAILS FOR FURTHER DETAIL. FOR PLANT TYPES REFER SYMBOLS TO PLANTING                                                                                           (P10).                                            DEPTH. BUILDING STRUCTURE                          **DEPTHS AND WEIGHTS TO BE APPROVED BY PROJECT ENGINEER**                                                     GEOFF HEARD
                                                                                     SCHEDULE.                                                                                                                                                                                                         CONTAINED.                                                                                                                                                       1300 182 341
                                                                                                                                                                                                                                                                                                                                                         PLANTER PROFILE (TOP TO BOTTOM): 50MM DEPTH OF PREMIUM FINE CYPRESS MULCH TO                                   CONTACT SITE: MIKE HEARD
7.2    PLANTER TYPE 5.                            PLANTER TYPE 5. (P5)               PLANTER DEPTH: TYPICALLY 500MM DEPTH. ALL PLANTER FINISH SET DOWN FROM           FYTOGREEN                                                                                                                                                                          AS4454 SAMPLE MUST BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO INSTALL,                                        0417622228
       CONTAINERISED INTENSIVE.                   CONTAINERISED PLANTER 500MM        BUILDING AT REQUIRED HEIGHT AND HAVE ADEQUATE FALLS AWAY FROM BUILDING.          CONTACT OFFICE:                                                                                                                                                                    (REMAINING DEPTH) HYDROCELL 40 PODIUM MIX MOUNDED AS DETAILED ABOVE, A24
       (P5).                                      DEPTH. BUILDING STRUCTURE          REFER TO ARCHITECTS AND ENGINEERS DRAWINGS FOR DETAIL.                           GEOFF HEARD                                                                                                                                                                        GEOTEXTILE TO BASE AND MINIMUM 200MM UP WALLS, 60MM HYDROCELL RG30 FOAM        MEDIA
                                                  CONTAINED ON CAPPING SLAB.         **DEPTHS AND WEIGHTS TO BE APPROVED BY PROJECT ENGINEER**                        1300 182 341                                                                                                                                                                       LAYER TO BASE, 20MM DRAINAGE CELL TO BASE AND 2.5MM CORFLUTE SHEET PROTECTION NUGROW
                                                                                                                                                                      CONTACT SITE: MIKE HEARD                                                                                                                                                           TO WATERPROOFING MEMBRANE ON BASE AND WALLS UP TO FINISHED MEDIA LEVEL.        CONTACT: KANE HAUSER
                                                                                     PLANTER PROFILE (TOP TO BOTTOM): 50MM DEPTH PEBBLE MULCH 15MM NAMBUCCA           0417622228                                                                                                                                                                         WATERPROOFING MEMBRANE TO ARCHITECT'S SPECIFICATION. IRRIGATION: AUTOMATED     PH: 3294 1586
                                                                                     PEBBLE MULCH TO AS4454 SAMPLE MUST BE APPROVED BY LANDSCAPE ARCHITECT                                                                                                                                                                                               IRRIGATION SYSTEM CONNECTED TO WATER SUPPLY WITH CENTRAL CONTROLLER WITH
                                                                                     PRIOR TO INSTALL, (REMAINING DEPTH) HYDROCELL 40 PODIUM MIX MOUNDED AS           MEDIA
                                                                                                                                                                                                                                                                                                                                                         DAILY BACK TO BASE MONITORING. REFER TO PLANTER IRRIGATION ITEM DETAIL FOR ALL
                                                                                     DETAILED ABOVE, A24 GEOTEXTILE TO BASE AND MINIMUM 200MM UP WALLS, 60MM          NUGROW
                                                                                                                                                                                                                                                                                                                                                         PLANTERS. DRAINAGE: ALL CONTAINERISED PLANTERS TO HAVE DRAINAGE ALLOCATIONS
                                                                                     HYDROCELL RG30 FOAM LAYER TO BASE, 20MM DRAINAGE CELL TO BASE AND 2.5MM          CONTACT: KANE HAUSER
                                                                                                                                                                                                                                                                                                                                                         WITHIN THE BUILDING STRUCTURE AT REGULAR INTERVALS TO HYDRAULIC ENGINEER'S
                                                                                     CORFLUTE SHEET PROTECTION TO WATERPROOFING MEMBRANE ON BASE AND WALLS            PH: 3294 1586
                                                                                                                                                                                                                                                                                                                                                         SPECIFICATION. DRAINAGE SUMP OUTLETS TO HAVE SPS TRUFLO 100MM WITH
                                                                                     UP TO FINISHED MEDIA LEVEL. WATERPROOFING MEMBRANE TO ARCHITECT'S                                                                                                                                                                                                   ALL-PURPOSE PLANTER BOX ADAPTOR, FITTED WITH SLOTTED 100MM PVC PIPE WITH
                                                                                     SPECIFICATION. IRRIGATION: AUTOMATED IRRIGATION SYSTEM CONNECTED TO WATER                                                                                                                                                                                           SCREW ON CAP, PIPE SHOULD BE WRAPPED IN GEOFABRIC. REFER TO TYPICAL DETAILS
                                                                                     SUPPLY WITH CENTRAL CONTROLLER WITH DAILY BACK TO BASE MONITORING. REFER TO                                                                                                                                                                                         FOR FURTHER DETAIL. FOR PLANT TYPES REFER SYMBOLS TO PLANTING SCHEDULE.
                                                                                     PLANTER IRRIGATION ITEM DETAIL FOR ALL PLANTERS. DRAINAGE: ALL CONTAINERISED
                                                                                     PLANTERS TO HAVE DRAINAGE ALLOCATIONS WITHIN THE BUILDING STRUCTURE AT                                                                             7.8          PLANTER TYPE 11                                   PLANTER TYPE 11. (P11)                            PLANTER DEPTH: TYPICALLY 720MM DEPTH. ALL PLANTER FINISH LEVELS TO BE 50MM SET                                  FYTOGREEN
                                                                                     REGULAR INTERVALS TO HYDRAULIC ENGINEER'S SPECIFICATION. DRAINAGE SUMP                                                                                          CONTAINERISED INTENSIVE.                          CONTAINERISED PLANTER 720MM                       DOWN FROM TOP OF ADJOINING PLANTER (BUILDING SILL) WALLS.                                                       CONTACT OFFICE:
                                                                                     OUTLETS TO HAVE SPS TRUFLO 100MM WITH ALL-PURPOSE PLANTER BOX ADAPTOR,                                                                                          (P11.                                             DEPTH. BUILDING STRUCTURE                         **DEPTHS AND WEIGHTS TO BE APPROVED BY PROJECT ENGINEER**                                                       GEOFF HEARD
                                                                                     FITTED WITH SLOTTED 100MM PVC PIPE WITH SCREW ON CAP, PIPE SHOULD BE WRAPPED                                                                                                                                      CONTAINED.                                                                                                                                                        1300 182 341
                                                                                     IN GEOFABRIC. REFER TO TYPICAL DETAILS FOR FURTHER DETAIL. FOR PLANT TYPES                                                                                                                                                                                          PLANTER PROFILE (TOP TO BOTTOM): 50MM DEPTH OF PREMIUM FINE CYPRESS MULCH TO                                    CONTACT SITE: MIKE HEARD
                                                                                     REFER SYMBOLS TO PLANTING SCHEDULE.                                                                                                                                                                                                                                 AS4454 SAMPLE MUST BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO INSTALL,                                         0417622228
                                                                                                                                                                                                                                                                                                                                                         (REMAINING DEPTH) HYDROCELL 40 PODIUM MIX MOUNDED AS DETAILED ABOVE, A24
7.3    PLANTER TYPE 6.                            PLANTER TYPE 6. (P6)               PLANTER DEPTH: TYPICALLY 100MM FALLING TO 200MM DEPTH. ALL PLANTER FINISH SET    FYTOGREEN                                                                                                                                                                          GEOTEXTILE TO BASE AND MINIMUM 200MM UP WALLS, 60MM HYDROCELL RG30 FOAM        MEDIA
       CONTAINERISED INTENSIVE.                   CONTAINERISED PLANTER              DOWN FROM BUILDING AT REQUIRED HEIGHT AND HAVE ADEQUATE FALLS AWAY FROM          CONTACT OFFICE:                                                                                                                                                                    LAYER TO BASE, 20MM DRAINAGE CELL TO BASE AND 2.5MM CORFLUTE SHEET PROTECTION NUGROW
       (P6).                                      100-200MM DEPTH. WESTERN SIDE.     BUILDING. REFER TO ARCHITECTS AND ENGINEERS DRAWINGS FOR DETAIL.                 GEOFF HEARD                                                                                                                                                                        TO WATERPROOFING MEMBRANE ON BASE AND WALLS UP TO FINISHED MEDIA LEVEL.        CONTACT: KANE HAUSER
                                                  BUILDING STRUCTURE                 **DEPTHS AND WEIGHTS TO BE APPROVED BY PROJECT ENGINEER**                        1300 182 341                                                                                                                                                                       WATERPROOFING MEMBRANE TO ARCHITECT'S SPECIFICATION. IRRIGATION: AUTOMATED     PH: 3294 1586
                                                  CONTAINED.ON BASEMENT SLAB.                                                                                         CONTACT SITE: MIKE HEARD                                                                                                                                                           IRRIGATION SYSTEM CONNECTED TO WATER SUPPLY WITH CENTRAL CONTROLLER WITH
                                                                                     PLANTER PROFILE (TOP TO BOTTOM): 50MM DEPTH OF PREMIUM FINE CYPRESS MULCH        0417622228                                                                                                                                                                         DAILY BACK TO BASE MONITORING. REFER TO PLANTER IRRIGATION ITEM DETAIL FOR ALL
                                                                                     MULCH TO AS4454 SAMPLE MUST BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO                                                                                                                                                                                             PLANTERS. DRAINAGE: ALL CONTAINERISED PLANTERS TO HAVE DRAINAGE ALLOCATIONS
                                                                                     INSTALL, (REMAINING DEPTH) HYDROCELL 40 PODIUM MIX MOUNDED AS DETAILED ABOVE,    MEDIA
                                                                                                                                                                      NUGROW                                                                                                                                                                             WITHIN THE BUILDING STRUCTURE AT REGULAR INTERVALS TO HYDRAULIC ENGINEER'S
                                                                                     A24 GEOTEXTILE TO BASE AND MINIMUM 200MM UP WALLS, 20MM DRAINAGE CELL TO                                                                                                                                                                                            SPECIFICATION. DRAINAGE SUMP OUTLETS TO HAVE SPS TRUFLO 100MM WITH
                                                                                     BASE AND 2.5MM CORFLUTE SHEET PROTECTION TO WATERPROOFING MEMBRANE ON            CONTACT: KANE HAUSER
                                                                                                                                                                      PH: 3294 1586                                                                                                                                                                      ALL-PURPOSE PLANTER BOX ADAPTOR, FITTED WITH SLOTTED 100MM PVC PIPE WITH
                                                                                     BASE AND WALLS UP TO FINISHED MEDIA LEVEL. WATERPROOFING MEMBRANE TO                                                                                                                                                                                                SCREW ON CAP, PIPE SHOULD BE WRAPPED IN GEOFABRIC. REFER TO TYPICAL DETAILS
                                                                                     ARCHITECT'S SPECIFICATION. IRRIGATION: AUTOMATED IRRIGATION SYSTEM                                                                                                                                                                                                  FOR FURTHER DETAIL. FOR PLANT TYPES REFER SYMBOLS TO PLANTING SCHEDULE.
                                                                                     CONNECTED TO WATER SUPPLY WITH CENTRAL CONTROLLER WITH DAILY BACK TO BASE
                                                                                     MONITORING. REFER TO PLANTER IRRIGATION ITEM DETAIL FOR ALL PLANTERS.                                                                              7.9          PLANTER TYPE 12.                                  PLANTER TYPE 12. (P12)                            PLANTER DEPTH: TYPICALLY 200MM DEPTH. ALL PLANTER FINISH LEVELS TO BE 50MM SET                                  FYTOGREEN




                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    FOR OPERATIONAL WORKS APPROVAL
                                                                                     DRAINAGE: ALL CONTAINERISED PLANTERS TO HAVE DRAINAGE ALLOCATIONS WITHIN                                                                                        CONTAINERISED INTENSIVE.                          CONTAINERISED PLANTER 200MM                       DOWN FROM TOP OF ADJOINING PLANTER (BUILDING SILL) WALLS.                                                       CONTACT OFFICE:
                                                                                     THE BUILDING STRUCTURE AT REGULAR INTERVALS TO HYDRAULIC ENGINEER'S                                                                                             (P12).                                            DEPTH. BUILDING STRUCTURE                         **DEPTHS AND WEIGHTS TO BE APPROVED BY PROJECT ENGINEER**                                                       GEOFF HEARD
                                                                                     SPECIFICATION. DRAINAGE SUMP OUTLETS TO HAVE SPS TRUFLO 100MM WITH                                                                                                                                                CONTAINED.                                                                                                                                                        1300 182 341
                                                                                     ALL-PURPOSE PLANTER BOX ADAPTOR, FITTED WITH SLOTTED 100MM PVC PIPE WITH                                                                                                                                                                                            PLANTER PROFILE (TOP TO BOTTOM): 50MM DEPTH OF PREMIUM FINE CYPRESS MULCH TO                                    CONTACT SITE: MIKE HEARD
                                                                                     SCREW ON CAP, PIPE SHOULD BE WRAPPED IN GEOFABRIC. REFER TO TYPICAL DETAILS                                                                                                                                                                                         AS4454 SAMPLE MUST BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO INSTALL,                                         0417622228
                                                                                     FOR FURTHER DETAIL. FOR PLANT TYPES REFER SYMBOLS TO PLANTING SCHEDULE.                                                                                                                                                                                             (REMAINING DEPTH) HYDROCELL 40 PODIUM MIX MOUNDED AS DETAILED ABOVE, A24
                                                                                                                                                                                                                                                                                                                                                         GEOTEXTILE TO BASE AND MINIMUM 200MM UP WALLS, 20MM DRAINAGE CELL TO BASE AND MEDIA
                                                                                                                                                                                                                                                                                                                                                         2.5MM CORFLUTE SHEET PROTECTION TO WATERPROOFING MEMBRANE ON BASE AND         NUGROW
7.4    PLANTER TYPE 7.                            PLANTER TYPE 7. (P7) PLANTER ON    PLANTER DEPTH: 400MM DEPTH. ALL PLANTER FINISH SET DOWN FROM BUILDING AT         FYTOGREEN
                                                                                                                                                                                                                                                                                                                                                         WALLS UP TO FINISHED MEDIA LEVEL. WATERPROOFING MEMBRANE TO ARCHITECT'S       CONTACT: KANE HAUSER
       (P7)                                       GROUND 400MM . BUILDING            REQUIRED HEIGHT AND HAVE ADEQUATE FALLS AWAY FROM BUILDING.                      1300 182 341
                                                                                                                                                                                                                                                                                                                                                         SPECIFICATION. IRRIGATION: AUTOMATED IRRIGATION SYSTEM CONNECTED TO WATER     PH: 3294 1586
       INTENSIVE.                                 STRUCTURE CONTAINED.               ALL FOOTINGS TO BE 700MM BELOW FINISHED PLANTER LEVEL.                           CONTACT: MIKE HEARD
                                                                                     REFER TO ARCHITECTS AND ENGINEERS DRAWINGS FOR DETAIL.                           0417622228                                                                                                                                                                         SUPPLY WITH CENTRAL CONTROLLER WITH DAILY BACK TO BASE MONITORING. REFER TO
                                                                                                                                                                                                                                                                                                                                                         PLANTER IRRIGATION ITEM DETAIL FOR ALL PLANTERS. DRAINAGE: ALL CONTAINERISED
                                                                                     PLANTER PROFILE (TOP TO BOTTOM): 50MM DEPTH OF PREMIUM FINE CYPRESS MULCH        MEDIA                                                                                                                                                                              PLANTERS TO HAVE DRAINAGE ALLOCATIONS WITHIN THE BUILDING STRUCTURE AT
                                                                                     TO AS4454 SAMPLE MUST BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO INSTALL,       NUGROW                                                                                                                                                                             REGULAR INTERVALS TO HYDRAULIC ENGINEER'S SPECIFICATION. DRAINAGE SUMP
                                                                                     (REMAINING DEPTH) HYDROCELL 40 PODIUM MIX AS DETAILED ABOVE. FOR ANY             CONTACT: KANE HAUSER                                                                                                                                                               OUTLETS TO HAVE SPS TRUFLO 100MM WITH ALL-PURPOSE PLANTER BOX ADAPTOR,
                                                                                     FOOTINGS, SLABS OR CAPPING BEAMS USE A24 GEOTEXTILE 20MM DRAINAGE CELLTO         PH: 3294 1586                                                                                                                                                                      FITTED WITH SLOTTED 100MM PVC PIPE WITH SCREW ON CAP, PIPE SHOULD BE WRAPPED
                                                                                     BASE AND MINIMUM 200MM UP WALLS AND 2.5MM CORFLUTE SHEET PROTECTION TO                                                                                                                                                                                              IN GEOFABRIC. REFER TO TYPICAL DETAILS FOR FURTHER DETAIL. FOR PLANT TYPES
                                                                                     WATERPROOFING MEMBRANE ON BASE AND WALLS UP TO FINISHED MEDIA LEVEL.                                                                                                                                                                                                REFER SYMBOLS TO PLANTING SCHEDULE.
                                                                                     WATERPROOFING MEMBRANE TO ARCHITECT'S SPECIFICATION. IRRIGATION: AUTOMATED                                                                         7.10         PLANTER TYPE 13.                                  PLANTER TYPE 13. (P13)                            PLANTER DEPTH: TYPICALLY 900MM DEPTH. ALL PLANTER FINISH LEVELS TO BE 50MM SET                                  FYTOGREEN
                                                                                     IRRIGATION SYSTEM CONNECTED TO WATER SUPPLY WITH CENTRAL CONTROLLER WITH                                                                                        CONTAINERISED INTENSIVE.                          CONTAINERISED PLANTER 900MM                       DOWN FROM TOP OF ADJOINING PLANTER (BUILDING SILL) WALLS.                                                       CONTACT OFFICE:
                                                                                     DAILY BACK TO BASE MONITORING. REFER TO PLANTER IRRIGATION ITEM DETAIL FOR ALL                                                                                  (P13).                                            DEPTH. BUILDING STRUCTURE                         **DEPTHS AND WEIGHTS TO BE APPROVED BY PROJECT ENGINEER**                                                       GEOFF HEARD
                                                                                     PLANTERS. DRAINAGE: FREE DRAINING (IF NOT ALL RAISED PLANTERS TO HAVE                                                                                                                                             CONTAINED.                                                                                                                                                        1300 182 341
                                                                                     DRAINAGE ALLOCATIONS WITHIN THE BUILDING STRUCTURE AT REGULAR INTERVALS TO                                                                                                                                                                                          PLANTER PROFILE (TOP TO BOTTOM): 50MM DEPTH OF PREMIUM FINE CYPRESS MULCH TO                                    CONTACT SITE: MIKE HEARD
                                                                                     HYDRAULIC ENGINEER'S SPECIFICATION). DRAINAGE SUMP OUTLETS TO HAVE SPS                                                                                                                                                                                              AS4454 SAMPLE MUST BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO INSTALL,                                         0417622228
                                                                                     TRUFLO 100MM WITH ALL-PURPOSE PLANTER BOX ADAPTOR, FITTED WITH SLOTTED                                                                                                                                                                                              (REMAINING DEPTH) HYDROCELL 40 PODIUM MIX MOUNDED AS DETAILED ABOVE, A24
                                                                                     100MM PVC PIPE WITH SCREW ON CAP, PIPE SHOULD BE WRAPPED IN GEOFABRIC. REFER                                                                                                                                                                                        GEOTEXTILE TO BASE AND MINIMUM 200MM UP WALLS, 60MM HYDROCELL RG30 FOAM        MEDIA
                                                                                     TO TYPICAL DETAILS FOR FURTHER DETAIL. FOR PLANT TYPES REFER SYMBOLS TO                                                                                                                                                                                             LAYER TO BASE, 20MM DRAINAGE CELL TO BASE AND 2.5MM CORFLUTE SHEET PROTECTION  NUGROW
                                                                                     PLANTING SCHEDULE.                                                                                                                                                                                                                                                  TO WATERPROOFING MEMBRANE ON BASE AND WALLS UP TO FINISHED MEDIA LEVEL.        CONTACT: KANE HAUSER
7.5                                                                                  PLANTER DEPTH: 1550MM DEPTH. ALL PLANTER FINISH SET DOWN FROM BUILDING AT                                                                                                                                                                                           WATERPROOFING MEMBRANE TO ARCHITECT'S SPECIFICATION. IRRIGATION: AUTOMATED     PH: 3294 1586
       PLANTER TYPE 8.                             PLANTER TYPE 8. (P8) PLANTER ON                                                                                    FYTOGREEN
       (P8)                                        GROUND 1550MM . BUILDING          REQUIRED HEIGHT AND HAVE ADEQUATE FALLS AWAY FROM BUILDING. REFER TO             1300 182 341                                                                                                                                                                       IRRIGATION SYSTEM CONNECTED TO WATER SUPPLY WITH CENTRAL CONTROLLER WITH
       INTENSIVE.                                  STRUCTURE CONTAINED.              ARCHITECTS AND ENGINEERS DRAWINGS FOR DETAIL.                                    CONTACT: MIKE HEARD                                                                                                                                                                DAILY BACK TO BASE MONITORING. REFER TO PLANTER IRRIGATION ITEM DETAIL FOR ALL
                                                                                                                                                                      0417622228                                                                                                                                                                         PLANTERS. DRAINAGE: ALL CONTAINERISED PLANTERS TO HAVE DRAINAGE ALLOCATIONS
                                                                                     PLANTER PROFILE (TOP TO BOTTOM): 50MM DEPTH OF PREMIUM FINE CYPRESS MULCH                                                                                                                                                                                           WITHIN THE BUILDING STRUCTURE AT REGULAR INTERVALS TO HYDRAULIC ENGINEER'S
                                                                                     TO AS4454 SAMPLE MUST BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO INSTALL,       MEDIA                                                                                                                                                                              SPECIFICATION. DRAINAGE SUMP OUTLETS TO HAVE SPS TRUFLO 100MM WITH
                                                                                     (REMAINING DEPTH) HYDROCELL 40 PODIUM MIX AS DETAILED ABOVE, A24 GEOTEXTILE      NUGROW                                                                                                                                                                             ALL-PURPOSE PLANTER BOX ADAPTOR, FITTED WITH SLOTTED 100MM PVC PIPE WITH
                                                                                     TO BASE AND MINIMUM 200MM UP WALLS AND 2.5MM CORFLUTE SHEET PROTECTION TO        CONTACT: KANE HAUSER                                                                                                                                                               SCREW ON CAP, PIPE SHOULD BE WRAPPED IN GEOFABRIC. REFER TO TYPICAL DETAILS
                                                                                     WATERPROOFING MEMBRANE ON BASE AND WALLS UP TO FINISHED MEDIA LEVEL. (ANY        PH: 3294 1586                                                                                                                                                                      FOR FURTHER DETAIL. FOR PLANT TYPES REFER SYMBOLS TO PLANTING SCHEDULE.
                                                                                     FOOTINGS OR BASE STRUCTURES TO HAVE 20MM DRAINAGE CELL TO BASE)
                                                                                     WATERPROOFING MEMBRANE TO ARCHITECT'S SPECIFICATION. IRRIGATION: AUTOMATED                                                                         7.11         PLANTER TYPE 14.                                 PLANTER TYPE 14. (P14)                             PLANTER DEPTH: TYPICALLY 400MM DEPTH. PLANTER FINISH LEVELS TO BE (MIN) 1200MM                                 FYTOGREEN
                                                                                     IRRIGATION SYSTEM CONNECTED TO WATER SUPPLY WITH CENTRAL CONTROLLER WITH                                                                                        CONTAINERISED INTENSIVE.                         CONTAINERISED PLANTER 400MM                        SET DOWN FROM TOP OF POOL AND (MAX) 990MM SET DOWN FROM TERRACE.                                               CONTACT OFFICE:
                                                                                     DAILY BACK TO BASE MONITORING. REFER TO PLANTER IRRIGATION ITEM DETAIL FOR ALL                                                                                  (P14).                                           DEPTH. BUILDING STRUCTURE                          **DEPTHS AND WEIGHTS TO BE APPROVED BY PROJECT ENGINEER**                                                      GEOFF HEARD
                                                                                     PLANTERS. DRAINAGE: FREE DRAINING (IF NOT ALL RAISED PLANTERS TO HAVE                                                                                                                                            CONTAINED.                                                                                                                                                        1300 182 341
                                                                                     DRAINAGE ALLOCATIONS WITHIN THE BUILDING STRUCTURE AT REGULAR INTERVALS TO                                                                                                                                                                                          PLANTER PROFILE (TOP TO BOTTOM): 50MM DEPTH OF PREMIUM FINE CYPRESS MULCH TO                                   CONTACT SITE: MIKE HEARD
                                                                                     HYDRAULIC ENGINEER'S SPECIFICATION). DRAINAGE SUMP OUTLETS TO HAVE SPS                                                                                                                                                                                              AS4454 SAMPLE MUST BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO INSTALL,                                        0417622228
                                                                                     TRUFLO 100MM WITH ALL-PURPOSE PLANTER BOX ADAPTOR, FITTED WITH SLOTTED                                                                                                                                                                                              (REMAINING DEPTH) HYDROCELL 40 PODIUM MIX MOUNDED AS DETAILED ABOVE, A24
                                                                                     100MM PVC PIPE WITH SCREW ON CAP, PIPE SHOULD BE WRAPPED IN GEOFABRIC. REFER                                                                                                                                                                                        GEOTEXTILE TO BASE AND MINIMUM 200MM UP WALLS, 60MM HYDROCELL RG30 FOAM        MEDIA
                                                                                     TO TYPICAL DETAILS FOR FURTHER DETAIL. FOR PLANT TYPES REFER SYMBOLS TO                                                                                                                                                                                             LAYER TO BASE, 20MM DRAINAGE CELL TO BASE AND 2.5MM CORFLUTE SHEET PROTECTION NUGROW
                                                                                     PLANTING SCHEDULE.                                                                                                                                                                                                                                                  TO WATERPROOFING MEMBRANE ON BASE AND WALLS UP TO FINISHED MEDIA LEVEL.        CONTACT: KANE HAUSER
                                                                                                                                                                                                                                                                                                                                                         WATERPROOFING MEMBRANE TO ARCHITECT'S SPECIFICATION. IRRIGATION: AUTOMATED     PH: 3294 1586
                                                                                                                                                                                                                                                                                                                                                         IRRIGATION SYSTEM CONNECTED TO WATER SUPPLY WITH CENTRAL CONTROLLER WITH
                                                                                                                                                                                                                                                                                                                                                         DAILY BACK TO BASE MONITORING. REFER TO PLANTER IRRIGATION ITEM DETAIL FOR ALL
                                                                                                                                                                                                                                                                                                                                                         PLANTERS. DRAINAGE: ALL CONTAINERISED PLANTERS TO HAVE DRAINAGE ALLOCATIONS
                                                                                                                                                                                                                                                                                                                                                         WITHIN THE BUILDING STRUCTURE AT REGULAR INTERVALS TO HYDRAULIC ENGINEER'S
                                                                                                                                                                                                                                                                                                                                                         SPECIFICATION. DRAINAGE SUMP OUTLETS TO HAVE SPS TRUFLO 100MM WITH
                                                                                                                                                                                                                                                                                                                                                         ALL-PURPOSE PLANTER BOX ADAPTOR, FITTED WITH SLOTTED 100MM PVC PIPE WITH
                                                                                                                                                                                                                                                                                                                                                         SCREW ON CAP, PIPE SHOULD BE WRAPPED IN GEOFABRIC. REFER TO TYPICAL DETAILS
                                                                                                                                                                                                                                                                                                                                                         FOR FURTHER DETAIL. FOR PLANT TYPES REFER SYMBOLS TO PLANTING SCHEDULE.




                                                                                                                                                                                                                                                                                                                                                                                                                                                     NOT FOR CONSTRUCTION
                                                                                                                                                                                                                                                                                                                                                                                    THE BUILDER / CONTRACTOR SHALL VERIFY JOB DIMENSIONS PRIOR TO ANY WORK COMMENCING. FIGURED DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED WORK.




                         CONLON                                                                                                     DATE     ISS DESCRIPTION
                                                                                                                                    19.02.24 B   FOR OPERATIONAL WORKS
                                                                                                                                                                                 CHKD CLIENT
                                                                                                                                                                                   MC
                                                                                                                                                                                        NOOSA RIVER HOUSES
                                                                                                                                                                                                                                                                   PROJECT
                                                                                                                                                                                                                                                                   128 GYMPIE TERRACE,
                                                                                                                                                                                                                                                                                                                                                                  LANDSCAPE DOCUMENTATION PACKAGE
                                                                                                                                                                                                                                                                                                                                                                  SCHEDULE OF FINISHES
                                                                                                                                                                                                                                                                                                                                                                                                                                                     PROJECT. NO.
                                                                                                                                                                                                                                                                                                                                                                                                                                                     578
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  DWG. NO.                             ISSUE


                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   LP003 B
                                                                                                                                                 APPROVAL

                         GROUP                                                                                                      08.02.24 A                                    MC                                                                                                                                                                                                                                                                 SCALE
                                                                                                                                                 FOR COORDINATION
                                                                                                                                                                                                                                                                   NOOSAVILLE, QUEENSLAND
                         P 07 5338 8690 E [email protected]                                                                                                                  © COPYRIGHT THIS DRAWING IS COPYRIGHT AND THE PROPERTY OF CONLON GROUP PTY. LTD. AND MUST NOT BE RETAINED, COPIED/REPRODUCED OR USED WITHOUT WRITTEN AUTHORITY.

Used in these records

About this file

File size
8.1 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Landscaping Plans 578_240219_CG_LDP_ISU B RIVER HOUSES GYMPIE TERRACE NOOSAVILLE-PACKAGE.pdf · 8.1 MB (large file)