Council archive · source document
Landscaping Plans 578_240219_CG_LDP_ISU B RIVER HOUSES GYMPIE TERRACE NOOSAVILLE-PACKAGE · OPW23/0179
Plans and drawings: the text below has words only, no drawings.
SCHEDULE OF FINISHES
NO. ITEM PRODUCT DESCRIPTION FINISH SUPPLIER NO. ITEM PRODUCT DESCRIPTION FINISH SUPPLIER
PLANTERS 7.6 PLANTER TYPE 9. PLANTER TYPE 9. (P9) PLANTER ON PLANTER DEPTH: 2500MM DEPTH. PLANTER FINISH LEVELS TO BE (MIN) 50MM SET DOWN FYTOGREEN
(P9) GROUND 2500MM . BUILDING FROM TOP OF ADJOINING PLANTER WALLS AND GLAZING FRAMES. 1300 182 341
7.1 PLANTER TYPE 4. PLANTER TYPE 4. (P4) PLANTER DEPTH: TYPICALLY 100MM FALLING TO 200MM DEPTH. ALL PLANTER FINISH SET FYTOGREEN INTENSIVE. STRUCTURE CONTAINED. CONTACT: MIKE HEARD
CONTAINERISED INTENSIVE. CONTAINERISED PLANTER DOWN FROM BUILDING AT REQUIRED HEIGHT AND HAVE ADEQUATE FALLS AWAY FROM CONTACT OFFICE: PLANTER PROFILE (TOP TO BOTTOM): 50MM DEPTH OF PREMIUM FINE CYPRESS MULCH 0417622228
(P4). 100-200MM DEPTH. BUILDING BUILDING. REFER TO ARCHITECTS AND ENGINEERS DRAWINGS FOR DETAIL. GEOFF HEARD TO AS4454 SAMPLE MUST BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO INSTALL,
STRUCTURE CONTAINED.ON **DEPTHS AND WEIGHTS TO BE APPROVED BY PROJECT ENGINEER** 1300 182 341 (REMAINING DEPTH) HYDROCELL 40 PODIUM MIX AS DETAILED ABOVE, A24 GEOTEXTILE MEDIA
BASEMENT SLAB. CONTACT SITE: MIKE HEARD TO BASE AND MINIMUM 200MM UP WALLS AND 2.5MM CORFLUTE SHEET PROTECTION TO NUGROW
PLANTER PROFILE (TOP TO BOTTOM): 50MM DEPTH PEBBLE MULCH 15MM NAMBUCCA 0417622228 WATERPROOFING MEMBRANE ON BASE AND WALLS UP TO FINISHED MEDIA LEVEL. (ANY CONTACT: KANE HAUSER
PEBBLE MULCH TO AS4454 SAMPLE MUST BE APPROVED BY LANDSCAPE ARCHITECT FOOTINGS OR BASE STRUCTURES TO HAVE 20MM DRAINAGE CELL TO BASE) PH: 3294 1586
PRIOR TO INSTALL, (REMAINING DEPTH) HYDROCELL 40 PODIUM MIX MOUNDED AS MEDIA WATERPROOFING MEMBRANE TO ARCHITECT'S SPECIFICATION. IRRIGATION: AUTOMATED
DETAILED ABOVE, A24 GEOTEXTILE TO BASE AND MINIMUM 200MM UP WALLS, 20MM NUGROW IRRIGATION SYSTEM CONNECTED TO WATER SUPPLY WITH CENTRAL CONTROLLER WITH
DRAINAGE CELL TO BASE AND 2.5MM CORFLUTE SHEET PROTECTION TO CONTACT: KANE HAUSER DAILY BACK TO BASE MONITORING. REFER TO PLANTER IRRIGATION ITEM DETAIL FOR ALL
WATERPROOFING MEMBRANE ON BASE AND WALLS UP TO FINISHED MEDIA LEVEL. PH: 3294 1586 PLANTERS. DRAINAGE: FREE DRAINING (IF NOT ALL RAISED PLANTERS TO HAVE
WATERPROOFING MEMBRANE TO ARCHITECT'S SPECIFICATION. IRRIGATION: AUTOMATED DRAINAGE ALLOCATIONS WITHIN THE BUILDING STRUCTURE AT REGULAR INTERVALS TO
IRRIGATION SYSTEM CONNECTED TO WATER SUPPLY WITH CENTRAL CONTROLLER WITH HYDRAULIC ENGINEER'S SPECIFICATION). DRAINAGE SUMP OUTLETS TO HAVE SPS
DAILY BACK TO BASE MONITORING. REFER TO PLANTER IRRIGATION ITEM DETAIL FOR ALL TRUFLO 100MM WITH ALL-PURPOSE PLANTER BOX ADAPTOR, FITTED WITH SLOTTED
PLANTERS. DRAINAGE: ALL CONTAINERISED PLANTERS TO HAVE DRAINAGE 100MM PVC PIPE WITH SCREW ON CAP, PIPE SHOULD BE WRAPPED IN GEOFABRIC. REFER
ALLOCATIONS WITHIN THE BUILDING STRUCTURE AT REGULAR INTERVALS TO HYDRAULIC TO TYPICAL DETAILS FOR FURTHER DETAIL. FOR PLANT TYPES REFER SYMBOLS TO
ENGINEER'S SPECIFICATION. DRAINAGE SUMP OUTLETS TO HAVE SPS TRUFLO 100MM PLANTING SCHEDULE.
WITH ALL-PURPOSE PLANTER BOX ADAPTOR, FITTED WITH SLOTTED 100MM PVC PIPE 7.7 PLANTER TYPE 10. PLANTER TYPE 10. (P10) PLANTER DEPTH: TYPICALLY 300MM DEPTH. ALL PLANTER FINISH LEVELS TO BE 50MM SET FYTOGREEN
WITH SCREW ON CAP, PIPE SHOULD BE WRAPPED IN GEOFABRIC. REFER TO TYPICAL CONTAINERISED INTENSIVE. CONTAINERISED PLANTER 300MM DOWN FROM TOP OF ADJOINING PLANTER (BUILDING SILL) WALLS. CONTACT OFFICE:
DETAILS FOR FURTHER DETAIL. FOR PLANT TYPES REFER SYMBOLS TO PLANTING (P10). DEPTH. BUILDING STRUCTURE **DEPTHS AND WEIGHTS TO BE APPROVED BY PROJECT ENGINEER** GEOFF HEARD
SCHEDULE. CONTAINED. 1300 182 341
PLANTER PROFILE (TOP TO BOTTOM): 50MM DEPTH OF PREMIUM FINE CYPRESS MULCH TO CONTACT SITE: MIKE HEARD
7.2 PLANTER TYPE 5. PLANTER TYPE 5. (P5) PLANTER DEPTH: TYPICALLY 500MM DEPTH. ALL PLANTER FINISH SET DOWN FROM FYTOGREEN AS4454 SAMPLE MUST BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO INSTALL, 0417622228
CONTAINERISED INTENSIVE. CONTAINERISED PLANTER 500MM BUILDING AT REQUIRED HEIGHT AND HAVE ADEQUATE FALLS AWAY FROM BUILDING. CONTACT OFFICE: (REMAINING DEPTH) HYDROCELL 40 PODIUM MIX MOUNDED AS DETAILED ABOVE, A24
(P5). DEPTH. BUILDING STRUCTURE REFER TO ARCHITECTS AND ENGINEERS DRAWINGS FOR DETAIL. GEOFF HEARD GEOTEXTILE TO BASE AND MINIMUM 200MM UP WALLS, 60MM HYDROCELL RG30 FOAM MEDIA
CONTAINED ON CAPPING SLAB. **DEPTHS AND WEIGHTS TO BE APPROVED BY PROJECT ENGINEER** 1300 182 341 LAYER TO BASE, 20MM DRAINAGE CELL TO BASE AND 2.5MM CORFLUTE SHEET PROTECTION NUGROW
CONTACT SITE: MIKE HEARD TO WATERPROOFING MEMBRANE ON BASE AND WALLS UP TO FINISHED MEDIA LEVEL. CONTACT: KANE HAUSER
PLANTER PROFILE (TOP TO BOTTOM): 50MM DEPTH PEBBLE MULCH 15MM NAMBUCCA 0417622228 WATERPROOFING MEMBRANE TO ARCHITECT'S SPECIFICATION. IRRIGATION: AUTOMATED PH: 3294 1586
PEBBLE MULCH TO AS4454 SAMPLE MUST BE APPROVED BY LANDSCAPE ARCHITECT IRRIGATION SYSTEM CONNECTED TO WATER SUPPLY WITH CENTRAL CONTROLLER WITH
PRIOR TO INSTALL, (REMAINING DEPTH) HYDROCELL 40 PODIUM MIX MOUNDED AS MEDIA
DAILY BACK TO BASE MONITORING. REFER TO PLANTER IRRIGATION ITEM DETAIL FOR ALL
DETAILED ABOVE, A24 GEOTEXTILE TO BASE AND MINIMUM 200MM UP WALLS, 60MM NUGROW
PLANTERS. DRAINAGE: ALL CONTAINERISED PLANTERS TO HAVE DRAINAGE ALLOCATIONS
HYDROCELL RG30 FOAM LAYER TO BASE, 20MM DRAINAGE CELL TO BASE AND 2.5MM CONTACT: KANE HAUSER
WITHIN THE BUILDING STRUCTURE AT REGULAR INTERVALS TO HYDRAULIC ENGINEER'S
CORFLUTE SHEET PROTECTION TO WATERPROOFING MEMBRANE ON BASE AND WALLS PH: 3294 1586
SPECIFICATION. DRAINAGE SUMP OUTLETS TO HAVE SPS TRUFLO 100MM WITH
UP TO FINISHED MEDIA LEVEL. WATERPROOFING MEMBRANE TO ARCHITECT'S ALL-PURPOSE PLANTER BOX ADAPTOR, FITTED WITH SLOTTED 100MM PVC PIPE WITH
SPECIFICATION. IRRIGATION: AUTOMATED IRRIGATION SYSTEM CONNECTED TO WATER SCREW ON CAP, PIPE SHOULD BE WRAPPED IN GEOFABRIC. REFER TO TYPICAL DETAILS
SUPPLY WITH CENTRAL CONTROLLER WITH DAILY BACK TO BASE MONITORING. REFER TO FOR FURTHER DETAIL. FOR PLANT TYPES REFER SYMBOLS TO PLANTING SCHEDULE.
PLANTER IRRIGATION ITEM DETAIL FOR ALL PLANTERS. DRAINAGE: ALL CONTAINERISED
PLANTERS TO HAVE DRAINAGE ALLOCATIONS WITHIN THE BUILDING STRUCTURE AT 7.8 PLANTER TYPE 11 PLANTER TYPE 11. (P11) PLANTER DEPTH: TYPICALLY 720MM DEPTH. ALL PLANTER FINISH LEVELS TO BE 50MM SET FYTOGREEN
REGULAR INTERVALS TO HYDRAULIC ENGINEER'S SPECIFICATION. DRAINAGE SUMP CONTAINERISED INTENSIVE. CONTAINERISED PLANTER 720MM DOWN FROM TOP OF ADJOINING PLANTER (BUILDING SILL) WALLS. CONTACT OFFICE:
OUTLETS TO HAVE SPS TRUFLO 100MM WITH ALL-PURPOSE PLANTER BOX ADAPTOR, (P11. DEPTH. BUILDING STRUCTURE **DEPTHS AND WEIGHTS TO BE APPROVED BY PROJECT ENGINEER** GEOFF HEARD
FITTED WITH SLOTTED 100MM PVC PIPE WITH SCREW ON CAP, PIPE SHOULD BE WRAPPED CONTAINED. 1300 182 341
IN GEOFABRIC. REFER TO TYPICAL DETAILS FOR FURTHER DETAIL. FOR PLANT TYPES PLANTER PROFILE (TOP TO BOTTOM): 50MM DEPTH OF PREMIUM FINE CYPRESS MULCH TO CONTACT SITE: MIKE HEARD
REFER SYMBOLS TO PLANTING SCHEDULE. AS4454 SAMPLE MUST BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO INSTALL, 0417622228
(REMAINING DEPTH) HYDROCELL 40 PODIUM MIX MOUNDED AS DETAILED ABOVE, A24
7.3 PLANTER TYPE 6. PLANTER TYPE 6. (P6) PLANTER DEPTH: TYPICALLY 100MM FALLING TO 200MM DEPTH. ALL PLANTER FINISH SET FYTOGREEN GEOTEXTILE TO BASE AND MINIMUM 200MM UP WALLS, 60MM HYDROCELL RG30 FOAM MEDIA
CONTAINERISED INTENSIVE. CONTAINERISED PLANTER DOWN FROM BUILDING AT REQUIRED HEIGHT AND HAVE ADEQUATE FALLS AWAY FROM CONTACT OFFICE: LAYER TO BASE, 20MM DRAINAGE CELL TO BASE AND 2.5MM CORFLUTE SHEET PROTECTION NUGROW
(P6). 100-200MM DEPTH. WESTERN SIDE. BUILDING. REFER TO ARCHITECTS AND ENGINEERS DRAWINGS FOR DETAIL. GEOFF HEARD TO WATERPROOFING MEMBRANE ON BASE AND WALLS UP TO FINISHED MEDIA LEVEL. CONTACT: KANE HAUSER
BUILDING STRUCTURE **DEPTHS AND WEIGHTS TO BE APPROVED BY PROJECT ENGINEER** 1300 182 341 WATERPROOFING MEMBRANE TO ARCHITECT'S SPECIFICATION. IRRIGATION: AUTOMATED PH: 3294 1586
CONTAINED.ON BASEMENT SLAB. CONTACT SITE: MIKE HEARD IRRIGATION SYSTEM CONNECTED TO WATER SUPPLY WITH CENTRAL CONTROLLER WITH
PLANTER PROFILE (TOP TO BOTTOM): 50MM DEPTH OF PREMIUM FINE CYPRESS MULCH 0417622228 DAILY BACK TO BASE MONITORING. REFER TO PLANTER IRRIGATION ITEM DETAIL FOR ALL
MULCH TO AS4454 SAMPLE MUST BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO PLANTERS. DRAINAGE: ALL CONTAINERISED PLANTERS TO HAVE DRAINAGE ALLOCATIONS
INSTALL, (REMAINING DEPTH) HYDROCELL 40 PODIUM MIX MOUNDED AS DETAILED ABOVE, MEDIA
NUGROW WITHIN THE BUILDING STRUCTURE AT REGULAR INTERVALS TO HYDRAULIC ENGINEER'S
A24 GEOTEXTILE TO BASE AND MINIMUM 200MM UP WALLS, 20MM DRAINAGE CELL TO SPECIFICATION. DRAINAGE SUMP OUTLETS TO HAVE SPS TRUFLO 100MM WITH
BASE AND 2.5MM CORFLUTE SHEET PROTECTION TO WATERPROOFING MEMBRANE ON CONTACT: KANE HAUSER
PH: 3294 1586 ALL-PURPOSE PLANTER BOX ADAPTOR, FITTED WITH SLOTTED 100MM PVC PIPE WITH
BASE AND WALLS UP TO FINISHED MEDIA LEVEL. WATERPROOFING MEMBRANE TO SCREW ON CAP, PIPE SHOULD BE WRAPPED IN GEOFABRIC. REFER TO TYPICAL DETAILS
ARCHITECT'S SPECIFICATION. IRRIGATION: AUTOMATED IRRIGATION SYSTEM FOR FURTHER DETAIL. FOR PLANT TYPES REFER SYMBOLS TO PLANTING SCHEDULE.
CONNECTED TO WATER SUPPLY WITH CENTRAL CONTROLLER WITH DAILY BACK TO BASE
MONITORING. REFER TO PLANTER IRRIGATION ITEM DETAIL FOR ALL PLANTERS. 7.9 PLANTER TYPE 12. PLANTER TYPE 12. (P12) PLANTER DEPTH: TYPICALLY 200MM DEPTH. ALL PLANTER FINISH LEVELS TO BE 50MM SET FYTOGREEN
FOR OPERATIONAL WORKS APPROVAL
DRAINAGE: ALL CONTAINERISED PLANTERS TO HAVE DRAINAGE ALLOCATIONS WITHIN CONTAINERISED INTENSIVE. CONTAINERISED PLANTER 200MM DOWN FROM TOP OF ADJOINING PLANTER (BUILDING SILL) WALLS. CONTACT OFFICE:
THE BUILDING STRUCTURE AT REGULAR INTERVALS TO HYDRAULIC ENGINEER'S (P12). DEPTH. BUILDING STRUCTURE **DEPTHS AND WEIGHTS TO BE APPROVED BY PROJECT ENGINEER** GEOFF HEARD
SPECIFICATION. DRAINAGE SUMP OUTLETS TO HAVE SPS TRUFLO 100MM WITH CONTAINED. 1300 182 341
ALL-PURPOSE PLANTER BOX ADAPTOR, FITTED WITH SLOTTED 100MM PVC PIPE WITH PLANTER PROFILE (TOP TO BOTTOM): 50MM DEPTH OF PREMIUM FINE CYPRESS MULCH TO CONTACT SITE: MIKE HEARD
SCREW ON CAP, PIPE SHOULD BE WRAPPED IN GEOFABRIC. REFER TO TYPICAL DETAILS AS4454 SAMPLE MUST BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO INSTALL, 0417622228
FOR FURTHER DETAIL. FOR PLANT TYPES REFER SYMBOLS TO PLANTING SCHEDULE. (REMAINING DEPTH) HYDROCELL 40 PODIUM MIX MOUNDED AS DETAILED ABOVE, A24
GEOTEXTILE TO BASE AND MINIMUM 200MM UP WALLS, 20MM DRAINAGE CELL TO BASE AND MEDIA
2.5MM CORFLUTE SHEET PROTECTION TO WATERPROOFING MEMBRANE ON BASE AND NUGROW
7.4 PLANTER TYPE 7. PLANTER TYPE 7. (P7) PLANTER ON PLANTER DEPTH: 400MM DEPTH. ALL PLANTER FINISH SET DOWN FROM BUILDING AT FYTOGREEN
WALLS UP TO FINISHED MEDIA LEVEL. WATERPROOFING MEMBRANE TO ARCHITECT'S CONTACT: KANE HAUSER
(P7) GROUND 400MM . BUILDING REQUIRED HEIGHT AND HAVE ADEQUATE FALLS AWAY FROM BUILDING. 1300 182 341
SPECIFICATION. IRRIGATION: AUTOMATED IRRIGATION SYSTEM CONNECTED TO WATER PH: 3294 1586
INTENSIVE. STRUCTURE CONTAINED. ALL FOOTINGS TO BE 700MM BELOW FINISHED PLANTER LEVEL. CONTACT: MIKE HEARD
REFER TO ARCHITECTS AND ENGINEERS DRAWINGS FOR DETAIL. 0417622228 SUPPLY WITH CENTRAL CONTROLLER WITH DAILY BACK TO BASE MONITORING. REFER TO
PLANTER IRRIGATION ITEM DETAIL FOR ALL PLANTERS. DRAINAGE: ALL CONTAINERISED
PLANTER PROFILE (TOP TO BOTTOM): 50MM DEPTH OF PREMIUM FINE CYPRESS MULCH MEDIA PLANTERS TO HAVE DRAINAGE ALLOCATIONS WITHIN THE BUILDING STRUCTURE AT
TO AS4454 SAMPLE MUST BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO INSTALL, NUGROW REGULAR INTERVALS TO HYDRAULIC ENGINEER'S SPECIFICATION. DRAINAGE SUMP
(REMAINING DEPTH) HYDROCELL 40 PODIUM MIX AS DETAILED ABOVE. FOR ANY CONTACT: KANE HAUSER OUTLETS TO HAVE SPS TRUFLO 100MM WITH ALL-PURPOSE PLANTER BOX ADAPTOR,
FOOTINGS, SLABS OR CAPPING BEAMS USE A24 GEOTEXTILE 20MM DRAINAGE CELLTO PH: 3294 1586 FITTED WITH SLOTTED 100MM PVC PIPE WITH SCREW ON CAP, PIPE SHOULD BE WRAPPED
BASE AND MINIMUM 200MM UP WALLS AND 2.5MM CORFLUTE SHEET PROTECTION TO IN GEOFABRIC. REFER TO TYPICAL DETAILS FOR FURTHER DETAIL. FOR PLANT TYPES
WATERPROOFING MEMBRANE ON BASE AND WALLS UP TO FINISHED MEDIA LEVEL. REFER SYMBOLS TO PLANTING SCHEDULE.
WATERPROOFING MEMBRANE TO ARCHITECT'S SPECIFICATION. IRRIGATION: AUTOMATED 7.10 PLANTER TYPE 13. PLANTER TYPE 13. (P13) PLANTER DEPTH: TYPICALLY 900MM DEPTH. ALL PLANTER FINISH LEVELS TO BE 50MM SET FYTOGREEN
IRRIGATION SYSTEM CONNECTED TO WATER SUPPLY WITH CENTRAL CONTROLLER WITH CONTAINERISED INTENSIVE. CONTAINERISED PLANTER 900MM DOWN FROM TOP OF ADJOINING PLANTER (BUILDING SILL) WALLS. CONTACT OFFICE:
DAILY BACK TO BASE MONITORING. REFER TO PLANTER IRRIGATION ITEM DETAIL FOR ALL (P13). DEPTH. BUILDING STRUCTURE **DEPTHS AND WEIGHTS TO BE APPROVED BY PROJECT ENGINEER** GEOFF HEARD
PLANTERS. DRAINAGE: FREE DRAINING (IF NOT ALL RAISED PLANTERS TO HAVE CONTAINED. 1300 182 341
DRAINAGE ALLOCATIONS WITHIN THE BUILDING STRUCTURE AT REGULAR INTERVALS TO PLANTER PROFILE (TOP TO BOTTOM): 50MM DEPTH OF PREMIUM FINE CYPRESS MULCH TO CONTACT SITE: MIKE HEARD
HYDRAULIC ENGINEER'S SPECIFICATION). DRAINAGE SUMP OUTLETS TO HAVE SPS AS4454 SAMPLE MUST BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO INSTALL, 0417622228
TRUFLO 100MM WITH ALL-PURPOSE PLANTER BOX ADAPTOR, FITTED WITH SLOTTED (REMAINING DEPTH) HYDROCELL 40 PODIUM MIX MOUNDED AS DETAILED ABOVE, A24
100MM PVC PIPE WITH SCREW ON CAP, PIPE SHOULD BE WRAPPED IN GEOFABRIC. REFER GEOTEXTILE TO BASE AND MINIMUM 200MM UP WALLS, 60MM HYDROCELL RG30 FOAM MEDIA
TO TYPICAL DETAILS FOR FURTHER DETAIL. FOR PLANT TYPES REFER SYMBOLS TO LAYER TO BASE, 20MM DRAINAGE CELL TO BASE AND 2.5MM CORFLUTE SHEET PROTECTION NUGROW
PLANTING SCHEDULE. TO WATERPROOFING MEMBRANE ON BASE AND WALLS UP TO FINISHED MEDIA LEVEL. CONTACT: KANE HAUSER
7.5 PLANTER DEPTH: 1550MM DEPTH. ALL PLANTER FINISH SET DOWN FROM BUILDING AT WATERPROOFING MEMBRANE TO ARCHITECT'S SPECIFICATION. IRRIGATION: AUTOMATED PH: 3294 1586
PLANTER TYPE 8. PLANTER TYPE 8. (P8) PLANTER ON FYTOGREEN
(P8) GROUND 1550MM . BUILDING REQUIRED HEIGHT AND HAVE ADEQUATE FALLS AWAY FROM BUILDING. REFER TO 1300 182 341 IRRIGATION SYSTEM CONNECTED TO WATER SUPPLY WITH CENTRAL CONTROLLER WITH
INTENSIVE. STRUCTURE CONTAINED. ARCHITECTS AND ENGINEERS DRAWINGS FOR DETAIL. CONTACT: MIKE HEARD DAILY BACK TO BASE MONITORING. REFER TO PLANTER IRRIGATION ITEM DETAIL FOR ALL
0417622228 PLANTERS. DRAINAGE: ALL CONTAINERISED PLANTERS TO HAVE DRAINAGE ALLOCATIONS
PLANTER PROFILE (TOP TO BOTTOM): 50MM DEPTH OF PREMIUM FINE CYPRESS MULCH WITHIN THE BUILDING STRUCTURE AT REGULAR INTERVALS TO HYDRAULIC ENGINEER'S
TO AS4454 SAMPLE MUST BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO INSTALL, MEDIA SPECIFICATION. DRAINAGE SUMP OUTLETS TO HAVE SPS TRUFLO 100MM WITH
(REMAINING DEPTH) HYDROCELL 40 PODIUM MIX AS DETAILED ABOVE, A24 GEOTEXTILE NUGROW ALL-PURPOSE PLANTER BOX ADAPTOR, FITTED WITH SLOTTED 100MM PVC PIPE WITH
TO BASE AND MINIMUM 200MM UP WALLS AND 2.5MM CORFLUTE SHEET PROTECTION TO CONTACT: KANE HAUSER SCREW ON CAP, PIPE SHOULD BE WRAPPED IN GEOFABRIC. REFER TO TYPICAL DETAILS
WATERPROOFING MEMBRANE ON BASE AND WALLS UP TO FINISHED MEDIA LEVEL. (ANY PH: 3294 1586 FOR FURTHER DETAIL. FOR PLANT TYPES REFER SYMBOLS TO PLANTING SCHEDULE.
FOOTINGS OR BASE STRUCTURES TO HAVE 20MM DRAINAGE CELL TO BASE)
WATERPROOFING MEMBRANE TO ARCHITECT'S SPECIFICATION. IRRIGATION: AUTOMATED 7.11 PLANTER TYPE 14. PLANTER TYPE 14. (P14) PLANTER DEPTH: TYPICALLY 400MM DEPTH. PLANTER FINISH LEVELS TO BE (MIN) 1200MM FYTOGREEN
IRRIGATION SYSTEM CONNECTED TO WATER SUPPLY WITH CENTRAL CONTROLLER WITH CONTAINERISED INTENSIVE. CONTAINERISED PLANTER 400MM SET DOWN FROM TOP OF POOL AND (MAX) 990MM SET DOWN FROM TERRACE. CONTACT OFFICE:
DAILY BACK TO BASE MONITORING. REFER TO PLANTER IRRIGATION ITEM DETAIL FOR ALL (P14). DEPTH. BUILDING STRUCTURE **DEPTHS AND WEIGHTS TO BE APPROVED BY PROJECT ENGINEER** GEOFF HEARD
PLANTERS. DRAINAGE: FREE DRAINING (IF NOT ALL RAISED PLANTERS TO HAVE CONTAINED. 1300 182 341
DRAINAGE ALLOCATIONS WITHIN THE BUILDING STRUCTURE AT REGULAR INTERVALS TO PLANTER PROFILE (TOP TO BOTTOM): 50MM DEPTH OF PREMIUM FINE CYPRESS MULCH TO CONTACT SITE: MIKE HEARD
HYDRAULIC ENGINEER'S SPECIFICATION). DRAINAGE SUMP OUTLETS TO HAVE SPS AS4454 SAMPLE MUST BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO INSTALL, 0417622228
TRUFLO 100MM WITH ALL-PURPOSE PLANTER BOX ADAPTOR, FITTED WITH SLOTTED (REMAINING DEPTH) HYDROCELL 40 PODIUM MIX MOUNDED AS DETAILED ABOVE, A24
100MM PVC PIPE WITH SCREW ON CAP, PIPE SHOULD BE WRAPPED IN GEOFABRIC. REFER GEOTEXTILE TO BASE AND MINIMUM 200MM UP WALLS, 60MM HYDROCELL RG30 FOAM MEDIA
TO TYPICAL DETAILS FOR FURTHER DETAIL. FOR PLANT TYPES REFER SYMBOLS TO LAYER TO BASE, 20MM DRAINAGE CELL TO BASE AND 2.5MM CORFLUTE SHEET PROTECTION NUGROW
PLANTING SCHEDULE. TO WATERPROOFING MEMBRANE ON BASE AND WALLS UP TO FINISHED MEDIA LEVEL. CONTACT: KANE HAUSER
WATERPROOFING MEMBRANE TO ARCHITECT'S SPECIFICATION. IRRIGATION: AUTOMATED PH: 3294 1586
IRRIGATION SYSTEM CONNECTED TO WATER SUPPLY WITH CENTRAL CONTROLLER WITH
DAILY BACK TO BASE MONITORING. REFER TO PLANTER IRRIGATION ITEM DETAIL FOR ALL
PLANTERS. DRAINAGE: ALL CONTAINERISED PLANTERS TO HAVE DRAINAGE ALLOCATIONS
WITHIN THE BUILDING STRUCTURE AT REGULAR INTERVALS TO HYDRAULIC ENGINEER'S
SPECIFICATION. DRAINAGE SUMP OUTLETS TO HAVE SPS TRUFLO 100MM WITH
ALL-PURPOSE PLANTER BOX ADAPTOR, FITTED WITH SLOTTED 100MM PVC PIPE WITH
SCREW ON CAP, PIPE SHOULD BE WRAPPED IN GEOFABRIC. REFER TO TYPICAL DETAILS
FOR FURTHER DETAIL. FOR PLANT TYPES REFER SYMBOLS TO PLANTING SCHEDULE.
NOT FOR CONSTRUCTION
THE BUILDER / CONTRACTOR SHALL VERIFY JOB DIMENSIONS PRIOR TO ANY WORK COMMENCING. FIGURED DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED WORK.
CONLON DATE ISS DESCRIPTION
19.02.24 B FOR OPERATIONAL WORKS
CHKD CLIENT
MC
NOOSA RIVER HOUSES
PROJECT
128 GYMPIE TERRACE,
LANDSCAPE DOCUMENTATION PACKAGE
SCHEDULE OF FINISHES
PROJECT. NO.
578
DWG. NO. ISSUE
LP003 B
APPROVAL
GROUP 08.02.24 A MC SCALE
FOR COORDINATION
NOOSAVILLE, QUEENSLAND
P 07 5338 8690 E [email protected] © COPYRIGHT THIS DRAWING IS COPYRIGHT AND THE PROPERTY OF CONLON GROUP PTY. LTD. AND MUST NOT BE RETAINED, COPIED/REPRODUCED OR USED WITHOUT WRITTEN AUTHORITY.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Landscaping Plans 578_240219_CG_LDP_ISU B RIVER HOUSES GYMPIE TERRACE NOOSAVILLE-PACKAGE.pdfRelated documentApplication case desk ↗
About this file
- File size
- 8.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.