Council archive · source document
01.2 - Engineering Design (issue 2) · OPW18/0008
Attached to the e-mail Operational Works Application OPW18/0008 - Domestic Marine Structure at 6 Mermaid Quay NOOSAVILLE.
NOTES: 1. Do 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | | 10 11 | 12 | 13 | 14 | 15 | 16 Continue truss top chords . [to to frame raked ceiling. ROOF FRAMING SCHEDULE: WALL FRAMES: (2700mm high) FN CATER. determined for this site is N2 e wind category determined for this site is 1 T \ MARK | SIZE DESCRIPTION EXTERNAL: in accordance with AS4055 and AS1170.2. MN fi Ribbon plate: 35x90 MGP12 = SS LES SES SS SS x ‘afters ai mm crs. . . ieee + Rt 190x35 MGP12 Rafters at 900 Top plate: 35x90 MGP12 TIE_DOWN DETAILS: Il! 4 ll [A\ Studs: 90x35 MGP10 at 450mm crs. All walls to be tied down with M12 anchor rods | ll BI Minimum 200 PFC | Beam (single span) Bottom plate: 35x90 MGP10 (Direct on slab) at the ends of each wall, at side of openings, | To -StCT \s07/ Similar to B2 260x65 GLI7C Beam (cont. 2 spans) and then between at maximum of 1800mm I (Typical) yo i B3 | 190x35 MGP12 Beam (single span) INTERNAL LOAD BEARING: centers UNO. a | L B4 | 195365 GLI7C | Beem (single spon) Ribbon plate: 35x90 MGP12 TRUSSES a a RIUR': eam Top plate: 35x90 MGP12 TRUS obs. a ze a1 I ; Studer. ° 90x35 MGP10 at 450mm crs. HWD or SWO trusses at 900mm max centers. \ " wet 200x100x4.0 RHS Wind Beam Bottom plate: 35x90 MGP10 (Direct on slab) Truncated Girder (16) and Girder locations shown I] —— SESS | J WB2 | 195x85 GL17C Wind Beam are nominal only. Final positions (including truss Similar to || | ll [8 \ - Tr INTERNAL Non-LOAD BEARING: tie-down) are to be in strict accordance with Detail B | ! ll \s07/ il C2 75x75x4.0 SHS Column Top plate: 35x90 MGP10 the Truss Manufacturer's specifications. it T => —_—= S| = | (7 ical) I | I C3 200 PFC Column Studs: 90x35 MGP10 at 600mm crs. The Lintels and Beams shown have been designed [C\ | lI Similar to Outriggers to truss yp ll C4 150x50x4.0 RHS Column Bottom plate: 35x90 MGP10 (Direct on slab) to this girder layout. Please contact office for \s07/ UI | Detail R ’, ificatic I ss J| 89x89x5.0 SHS Column lintel re-designs if the Truss Manufacturer's I> | | manufacturer's specification 5 1 . (Typical) i} 7 T _ | _ i a a layout differs from the one shown herein. — = >- = I a NOTE: [0\ I q ll Roof bracing (Speedbrace or similar) and trusses —Tt Zt l iA — in accordance with the manufacturer's ll = — = \so7/ Il Tt Similar to (Typical) fp PT it il ms ) specifications Detail B I ll —~ +. ~ ~~. ~ JY I Bll uf Ll a il = | ed _ ll ' Similar to II —-+4 Detail B ll / SS SS OSs = Similar to FA \ Detail C — \ Il — a re ==4 Similar to || Z| \ BS (below) WIA VA VA VL LLLLLLLLN Detail B \ [| J — eee RR RIES SE SES SS SE SH SS i petal & 7} 7] 7 a i B5 (below) all —._—. — ll ' Similar tom II a | o = _ = _ _ B5 (below) Detail B NM —; 7d TF _t_t_t—_ ff a I I ce VI “Howl den bow! lol I | LBW LBW Sv MV (ot ee fe 1 sai it Lk\ I if 11 (Typical 3 i—| lll —|-\- | Girder not scale drawings. 2. Check and verify all dimensions prior to commencement of work. Support & tie-down girder at this location LL LL L LZ A TRUSS & FRAME LAYOUT (Ground Floor) Issue|Made By| Date _ DESCRIPTION PROPOSED NEW RESIDENCE at CONSULTING STRUCTURAL & CIVIL ENGINEERS]Scale: 1:100 =| 0 BDK 16/11/17 | Preliminary Issue — Not for Construction Office: Suite 8/137 Brisbane Road, Mooloolaba g 1 BDK | 04/12/17] Preliminary Issue — Not for Construction LOT 120 CNR SEAMOUNT QUAY & MERMAID QUAY, NOOSAVILLE Postal: P.O. Box 7117 Job No.: 17-0417 g 2 BDK | 11/12/17] Preliminary Issue — Not for Construction BUILDER: RYAN DESIGNER HOMES Sippy Downs, QLD. 4556 Dwg No : S05 a Designed By : J. SWEET BEng (Civil) (hons) Drawn By: BOK Date: 16/11/17 Ws eosetepoup m.cu TRUSS ke FRAME LAYOUT Certified By : B.R. CROMAR BEng (Civil) MIEAust CPEng RPEQ NER Date : 16/11/17 Email: [email protected] 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | | 10 11 | 12 | 13 | 14 | 15 | 16
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
01.2 - Engineering Design (issue 2).pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.