Proposal Report      Proposed Material Change of Use of Premises for a Multiple housing - Type 2 Duplex at 38 Park Crescent, Sunshine Beach
                     described as Lot 598 on RP48112


                 column 1                                        column 2                                           Column 3
             Specific Outcomes                    Probable solutions (if code assessable)                          Compliance

associated with Residential Uses are              including pool and spa pumps, pool              policies and standards.
designed and located so as not have an            heaters, air-conditioning units and
adverse impact on the visual amenity of the       refrigeration units are—
site or surrounding areas.                        a) where located at ground level,
                                                      screened by fencing 1.5m in height or
                                                      dense vegetation of at least 1.5m in
                                                      width incorporating grouped trees and
                                                      shrubs with maximum separation
                                                      distance of 1m measured from the
                                                      centre of the plant; and
                                                  b) for Multiple housing Type 2, 3 & 4
                                                      are visually integrated into the line and
                                                      plane of the building and roof design
                                                      and do not project beyond the height or
                                                      width of the building when viewed from
                                                      the street and adjoining properties.

Ancillary recreation uses
O11                                               S11.1                                           Not applicable
O12.
Privacy
O13 For Multiple Housing Types 2, 3 and           S13.1 Transparent doors and windows             Units have been designed to step down the
4, building and structures are designed and       are designed and located so they do not         building to take advantage of the slope and
sited to ensure the visual privacy of residents   directly face transparent doors or windows      the eastern water views.
of the development and neighbouring               or the private open space areas of other
properties is protected.                          dwelling units within 10 metres;                The northern facade of Unit 1 which is level
                                                  AND                                             with the adjoining residential dwelling to the
                                                  S13.2 Planter boxes, louvre screens,            north, includes high level windows and
                                                  pergolas, landscaping and architectural         screened walkways to minimise opportunities
                                                  design of balconies are used to screen the      for overlooking.
                                                  ground floor private open space of
                                                  dwelling units or accommodation units           The southern facade of Unit 1 includes
                                                  from upper level units (which illustrates       shutters around the upper level deck and
                                                  how trees, awnings, screens, fences and         second floor bedroom along with opaque
                                                  planter boxes reduce minimise the ability       louvers. The 3 metre side setback will also
                                                  to directly look into neighbouring homes        enable dense landscaping to be provided.
                                                  and yards).
Access to Sunlight
O14 For Multiple housing, buildings and           S14.1 Development does not reduce               The designer indicates that the proposal
structures are designed and sited so as not       sunlight to at least 50% of the private open    complies with this requirement.
to unreasonably diminish the existing             space areas of any adjoining residences to
sunlight to adjoining residences and              less to than 2 hours between 9am and
associated private open space areas;              3pm on any day of the year;
                                                  OR
AND                                               S14.2 Where overshadowing by existing
                                                  structures and fences occurs to more than
                                                  50% of the private open space areas of
                                                  any adjoining residences, sunlight is not
                                                  further reduced by more than 20%.

O15 Multiple housing is designed and sited        S15.1 No solution provided                      The building has been designed to step down
to minimise the extent of shadows cast on                                                         the site and is well below the maximum
solar photovoltaic cells on roofs of adjoining                                                    height limit.
buildings.
Sloping sites
O16 On sloping sites, buildings and               S16.1 Buildings and structures on sloping       Complies – undercroft screening provided.
structures are designed to maximise the use       sites—
of the natural topography and minimise the        a) Have a maximum distance of 3m
need for cut and fill.                            between the ground and the lowest part of
                                                  the floor of the building or the building
                                                  incorporates undercroft skirting or
                                                  screening (eg. timber battens) to the full
                                                  height of any undercroft area higher than
                                                  3m above ground level at the perimeter of
                                                  the building;
                                                  b) are of split level design that step down
                                                                                                                                             3|P a g e

Used in these records

About this file

File size
23 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Annexure F Residential use code.pdf · 23 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.