Original source · versioned page text
water and sewer design
Original PDF page 6, section 1. The text section number identifies this passage in the reader.
NOTE: FINISH FLOOR LEVEL TO BE
CONFIRMED ONSITE BEFORE
CONSTRUCTION & ADJUSTED TO
SCHEDULE OF FITTINGS
SUIT SITE CONDITIONS 24 2 DN50 90° BEND
DN50 DUAL CHECK VALVE INCLUDING Y-TYPE
23 1
NOTE: ALL WORKS TO BE IN STRAINER 16kPA SPRING
ACCORDANCE WITH
SEQ-WAT-1108-4 & 5 22 2 DN50 BALL VALVE
21 1 DN50 WATER METER
20 2 DN50 BALL VALVE
LIMIT OF ASSET INSTALLATION, OWNERSHIP
LIMIT OF ASSET INSTALLATION, OWNERSHIP & MAINTENANCE BY UNITYWATER
& MAINTENANCE BY UNITYWATER 19 1 DN50 90° BEND
NEW DN50 WATER SERVICE
18 1 DN150-50 TAPPING BAND
17 1 DN25 90° BEND
16 1 DN25 90° BEND
DN25 SINGLE CHECK VALVE INCLUDING
15 1
24 22 23 22 20 21 20 Y-TYPE STRAIN
19
14 2 DN25 BALL VALVE
13 1 DN25 WATER METER
12 2 DN25 BALL VALVE
EX E
A 24 NEW DN50 WATER SERVICE
SEM
ENT
11 2 DN150 90° BEND (FL-FL)
18 10 1 DN150-25 TAPPING BAND
5 3
DN150 SINGLE CHECK VALVE INCLUDING
9 1
Y-TYPE STRAIN 16kPA SPRING
NEW DN150 DICL WATER SERVICE
8 2 DN150 ISOLATION VALVE
4 7 1 DN150 ISOLATION VALVE
6 1 DN150-25 TAPPING BAND
11 10 8 9 8 7 6
5 2 DN150 90° BEND (FL-FL)
NEW DN25 WATER SERVICE 4 1 DN150 90° BEND (SOC-SOC)
NEW DN150 DICL WATER SERVICE
3 2 DN150 CONNECTOR (FL-SOC)
ATTENTION: UNITYWATER
PRIVATE WORKS TEAM 2 1 DN150 VALVE (FL-FL)
BOUNDARY 17 14 15 14 12 13 12 16
PRIOR TO CONNECTION UNITYWATER TO LIAISE 1 1 DN150-150 OFF-TAKE CLAMP
WITH CONTRACTOR ONSITE TO DETERMINE
FINAL HEIGHT OF ABOVE GROUND PIPE WORK INSTALLATION BY INSTALLATION BY
ITEM QTY DESCRIPTION
UNITYWATER DEVELOPER
HEADLAND DRIVE
LIMIT OF ASSET INSTALLATION,
OWNERSHIP & MAINTENANCE
BY UNITYWATER
S
D
S
4]
3
D
3 21
25
[ID
S
IN
D
MA
ER
3
AT
R
WE
MW
SE
OR
S
D
C
ST
2
V
uP
CP
0
0R
15
45
DN
D
S
DN
EX
EX
150W 150W 150W
150W 150W
D
150W 150W 150W 150W
150W 150W 150W 150W 150W 150W 150W
S
EX DN150 uPVC WM [ID2039251]
D
S
D
S
1
BAX
SCALE: SURVEYED: CLIENT: NORTH POINT TITLE:
0 0.1 0.2 0.3 0.4 0.5m
CAPITAL PRUDENTIAL PTY LTD WATER RETICULATION
Scale 1:10 - A1 (1:20 - A3)
DATUM: AHD DETAIL PLAN
A 07.08.23 ISSUE FOR APPROVAL QT MM
PROJECT NO:
146-007
LOCAL AUTHORITY APPROVAL NO:
DATE
CHECKED
DRAWN
07.08.23
MM
QT
APPROVED:
GLENN AINSWORTH
CPESC No: 7678
RPEQ No: 19204
Engineering
2261 DAVID LOW WAY, PEREGIAN BEACH, QLD 4573
PTY. LTD.
PROJECT:
79-83 EUMUNDI NOOSA RD & 26 HEADLAND DR
NOOSAVILLE QLD 4566
No. DATE REVISIONS BY CKD --- DESIGNED QT FOR AND ON BEHALF OF BAX ENGINEERING PTY. LTD. [email protected] PLAN No 146-007-602 REVISION A A3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the original