Council archive · source document
Approved Plans - MCU22/0197, OPW22/0296 & RAL22/0031
Plans and drawings: the text below has words only, no drawings.
Original PDF page 3, section 1. The text section number identifies this passage in the reader.
Timber frame truss roof to Eng. Roof insulation achieve the Min. Colorbond Custom Orb roof
detail and installed to man. spec 'R' rating in accordance with sheeting 'Surfmist'
NCC 2019 Vol. Two
8m HEIGHT LIMIT
9960
°
2 0.0 www.zestbuildingdesign.com.au
Aluminium hood installed to
man. spec.
4109
BOUNDARY
60/600/60 fire separation wall -
cladded with 150mm Weathertex -
STEEL HOOD SURROUND Weathergrove Natural cladding
WITH SCREENING
BOUNDARY
2700
Aluminium hood Raised planter box
installed to man. spec.
3700
1000 TOW. 42.489 m 8500
UNIT 1 - LVL 2
RL 44.500 m
TOW. 42.950 m RL 43.200 m
1800mm High timber pailing
fence along entire boundary
3000
UNIT 1
2700
Timber pergola with decorative fretwork
to detail. Painted Lexicon Half
NGL TOW. 41.650 m
2700
UNIT 1 - LEVEL 1 2325
RL 41.500 m
Garage Level
RL 40.500 m
Concrete block retaining wall to be in Rendered block wall to Eng. Footings and slab construction shall to be in accordance with engineers design Concrete driveway to Eng. design and detail. Timber screening fence to detail Rendered block wall to Eng.
accordance with structural engineers detail - selected paint finish and detail and ncc 3.2. Slab on ground is to be monolithic to be in accordance Driveway to comply with AS2890.1. Provide new detail - selected paint finish
design and detail. Provide with engineers design and detail and as 2870. Termite barriers to comply with crossover in accordance with local authority
waterproofing system to back of wall as 3660.1 and ncc 3.1.3. approved 'kordon' termite barriers are required to regulations. Driveway grades to be in accordance
with ag drain and free draining backfill. perimeter and penetrations of slab to be designed and installed by specialist with AS2890.1. Driveway to be in selected
approved contractor - guarantees are required by the owner from the coloured exposed aggregate concrete blend with,
manufacturer / installer of the termite barriers. Provide moisture barrier (200um) provide slip resistant clear penetrating sealer to
under slab with 200mm laps. securely tape joint entire driveway and applied in accordance with
manufacturers specifications.
1 Section
A.100 Unit 1 - Section A 1 : 75
Concrete block retaining wall to be in Swimming pool to be in accordance with engineers design Timber frame truss roof to Eng. Roof insulation achieve the Min. Timber framed ceiling/bulkheads Colorbond Custom Orb roof NOOSA COUNCIL
accordance with structural engineers and detail. All pool and spa construction to be in accordance detail and installed to man. spec 'R' rating in accordance with with square set plaster board sheeting 'Surfmist'
design and detail. Provide with manufacturers/installers specifications. Pool to have NCC 2019 Vol. Two sheeting.
APPROVED PLAN
waterproofing system to back of wall suitable pumps in accordance with manufacturers/installers MCU22/0197, OPW22/0296 & RAL22/0031
with ag drain and free draining backfill. specifications. Provide pool fence to be in accordance with
NCC 3.9.3, the Building Act 1993, Building Regulation 2006,
15 JUNE 2023
AS 1926 . Pool fence to be min. 1200mm high above
adjoining finished surface level and have 900mm non climbing
zone as specified in pool legislation
Disclaimer: Zest Building Design Pty. Ltd. retains all
common law, statutory law and other rights including
copyright and intellectual property rights in respect of this
document.
The recipient indemnifies Zest Building Design Pty. Ltd.
8m HEIGHT LIMIT against all claims resulting from use of this document for
Colorbond half round gutters & any purpose other than its intended use, unauthorized
Colorbond fascias 'Surfmist' changes or reuse of the document on other projects without
the permission of Zest Building Design Pty. Ltd.
BOUNDARY
BOUNDARY
1 0.0° 10.0 ° Under no circumstance shall transfer of this document be
7414 1m timber balustrade wall with deemed a sale or constitute a transfer of the license to use
selected timber top capping. Painted this document.
UNIT 2 - CEILING
10752 RL 46.050 m Revisions
A 31/01/2023 COUNCIL RFI TW
TOW. 44.550 m
TOW. 44.550 m B 24/04/2023 UNIT 1 BEDROOM WINDOW ICB
2550
SCREENING
2550
Timber pergola with decorative
fretwork to detail. Painted
6339
RL 43.200 m
TOW. 42.142 m 1 0.7 ° Timber screening fence to detail
UNIT 2 - LVL 2
RL 43.500 m
4965 9742
UNIT 2 TOW. 41.750 m
3000
COMPACT FILL
2700
1000
TOW. 40.200 m
Status
Garage Level
RL 40.500 m
NGL PERMIT ISSUE
Client
COMPACT FILL
IZAROX QLD PTY LTD
Cut and fill ratios and grade to Suspended timber floor to Footings and slab construction shall to be in accordance with engineers design Concrete driveway to Eng. design and detail.
Civil ENG. detail ENG. details and detail and ncc 3.2. Slab on ground is to be monolithic to be in accordance Driveway to comply with AS2890.1. Provide new
with engineers design and detail and as 2870. Termite barriers to comply with crossover in accordance with local authority Project
as 3660.1 and ncc 3.1.3. approved 'kordon' termite barriers are required to regulations. Driveway grades to be in accordance
perimeter and penetrations of slab to be designed and installed by specialist with AS2890.1. Driveway to be in selected Brighton Springs
approved contractor - guarantees are required by the owner from the coloured exposed aggregate concrete blend with,
manufacturer / installer of the termite barriers. Provide moisture barrier (200um) provide slip resistant clear penetrating sealer to
under slab with 200mm laps. securely tape joint entire driveway and applied in accordance with 73 SOUTHERNCROSS PRADE
manufacturers specifications. SUNRISE BEACH, QLD 4567
2 Section Drawing
A.100 Section 2 1 : 75
SECTIONS
Project No Date Author
22004 31/01/2023 TW
Scale: @ A1 Drawing No. Revision
1 : 75 A.300 B
24/04/2023 9:38:01 AM
Document Set ID: 22388184
Version: 1, Version Date: 28/04/2023
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plans - MCU22/0197, OPW22/0296 & RAL22/0031.pdfRelated documentApplication case desk ↗
About this file
- File size
- 6.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.