Council archive · source document
Revised Engineering Plans · MCU13/0261
Attached to the e-mail MCU13/0261 - Response to Information Request - 5 Stevens Street Sunshine Beach.
Plans and drawings: the text below has words only, no drawings.
! Revision | Description Date of ae | EXISTING STORM WATER S | INLET, INVERT LEVEL AND ot i| | LOCATION TO BE DETERMINED We | | | ON SITE. landscape steps — ) YL | DIAMOND CORE DRILL BACK 1506 SW uPVC Ld OF EXISTING STORM WATER INLET FOR CONNECTION. / GP2 | NON-SHRINK 40MPA GROUT Pe [ | | SURROUND 10 PIPE. + oe | dp if. REMOVE EXISTING CROSSOVER ae y/ | \ | AND REINSTATE KERB & / | | CHANNEL TO COUNCIL AREA 68.35 m? | STANDARDS | store under — f/f u / ete a . Be _ ol) \ | CONSTRUCTION NOTES ( poy 7 s | GENERAL: MP / | / \ | 1. DO NOT SCALE FROM THIS DRAWING. screen “ _f _\. \ 2. ALL DIMENSIONS IN MILLIMETRES ee 3, SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE ARCHITECTURAL \ DRAWINGS. p- CP? » 4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE ARCHITECTURAL 1008 S.W uPVC = =D] 1 HH DRAWINGS ARE TO BE REFERRED TO THE ENGINEER IMMEDIATELY. / / 5, THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING SERVICES l / . \]) WITHIN AND ADJACENT THE ALLOTMENT AND SHALL ENSURE THAT ALL NEW | ) | | WORKS ARE IN ACCORDANCE WTH THE ATTACHED CRITICAL DEPTH LINE vy retaining wall,” LU < to engineers detail ™ banquette 1. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL 2. CROSSINGS ARE NOT DESIGNED FOR COMMERCIAL VEHICLES 3. CONCRETE DRIVEWAY TO BE 125mm THK. EXCLUDING ANY FINISHED TREATMENTS, EG. STAMPING 4, CONCRETE SURFACE TOLERANCE +5.0mm OVER 3.0m 5. CONCRETE N25 IN ACCORDANCE WITH AS 1379 AND AS 3600 6. REINFORCEMENT FABRIC TO AS 1304, PLACED CENTRAL SLAB DEPTH. 7. EXPANSION JOINTS TO BE 10mm WIDE WET TOOLED WITH EVERY 2ND MESH WRE CUT ALONG JOINT. 8. ONE ACCESS POINT PERMITTED FOR EACH ALLOTMENT. 9. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO INSIDE EDGE OF CURVE 10. ALL SERVICES TO BE LOCATED AND PROTECTED AS REQUIRED PRIOR TO WORK COMMENCING HYDRAULICS 1. HYDRAULIC SERVICES SHOWN ARE DIAGRAMATIC ONLY. REFER 10 } ARCHITECTURAL DRAWINGS FOR LOCATIONS OF FIXTURES. /APPORVED 2. ALL SANITARY HYDRAULICS AND WATER RETICULATION WITHIN THE ALLOTMENT / BOUNDARY TO BE IN ACCORDANCE WITH AS3500. J KERB ADAPTOR 3. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION, AFTER OBTAINING ALL NECESSARY PERMITS AND APPROVALS. 4, THE CONTRACTOR IS TO CONFIRM THE POSITION OF ALL EXISTING SERVICES AS INDICATED ON THESE AND ASSOCIATED PLANS PRIOR TO THE COMMENCING OF WORK. 5. STORMWATER DRAINAGE PIPES SHALL BE CLASS SH UPVC OR HARDIES CLASS / 2(X) FRC PIPE LAID AT A MINIMUM GRADE OF 1 IN 100 U.N.O. JOINS ARE TO BE | / CONSTRUCTED IN ACCORDANCE WITH THE MANUFACTURERS REQUIREMENTS. 6. SEWERS 100MM DIAM. UPVC ULN.O. AND LAID AT A MINIMUM GRADE OF 1 IN 60. 7. WATER SUPPLY PIPEWORK BELOW GROUND IS TO BE ; 63MM DIAM, OR LESS - HIGH DENSITY TYPE 50 LEGEND CLASS 12 POLYETHYLENE 8 ALL ABOVE GROUND AND INTERNAL WATER SUPPLY PIPEWORK TO BE TYPE B yor —~ INDICATES EXISTING SURFACE COPPER. 8.0 9, WATER SERVICES ARE NOT PERMITTED IN GROUND SLABS AND ALL JOINS AND \ CONTOUR AND LEVEL TO AHD. CONNECTIONS SHALL BE MADE ABOVE THE SLAB. 10. FIRE HYDRANTS ARE TO BE INSTALLED ARE TO BE INSTALLED IN | __ST__ SIT RETENTION FENCE 10 DETAIL ACCORDANCE WITH AS2419.1. HOSE REELS ARE TO BE INSTALLED IN APPORVED ACCORDANCE WITH AS2441. ; a 11. CLEAN-OUTS, INSPECTION OPENINGS AND CLOSING CAPS SITUATED IN /KERB ADAPTOR 760] INDICATES PROPOSED FINISHED SPOT ——venicuLar OR PEDESTRIAN PAVEMENTS ARE TO BE FITTED WITH EITHER BRASS DISCHARGE RATES: OTAL ROOF AREA: 242.4m2 SURFACE LEVELS 10 AHD VEHOULAR OR PEDESTR 12. ALL IN-GROUND VALVES SHALL BE IN ACCORDANCE IN APPROVED CONCRETE RAIN FALL IN NOOSA AREA: 253 h - | r eooF OTAL FLOW RATES: 17.01 L /S ram / SE PLAN — SITE STORMWATER. L a / + EXISTING SURFACE SPOT LEVELS. 12 ALL WASTE PPES AND WATER SERVES PENETRATNG SLABS TO BE Lo oS _ iy I DIAGRAM. J - : a HH Z / : | | FOOTPATHS AND DRIVEWAYS: in 50(W) GRATED DRAI dp CPt ‘Pye "50 setbacy 0 SW Pie —_ ¢ landscape steps —/ —_ landscape steps WRAPPED IN AN APPROVED FLEXIBLE JOINT JOINT WRAPPING. Tr 14, THE TERM ’SERVICE’ REFERS TO THE MINIMUM INTERNAL PIPE DIAMETER Fal, INDICATES DIRECTION OF FALL UNLESS NOTED OTHERWISE. TO FINISHED SPOON DRAINS. FINISHED FLOOR LEVELS (AHD). | x [EST] INDICATES PROPOSED FINISHED SSU° ISSUE FOR CONST. UNIT 1 Ree structural - ty ENGINEERS Structural - civil - geotechnical GPS 450Sq GRATED OVER FLOW GARAGE: FFL 30.70 CONTRACTOR TO LOCATE ALL SERVICES PRIOR TO opr. ABN 40 098 481 899 A COMMENCING WORKS ON SITE. ALL SERVICES ARE RELIEF INLETS, PRE-CAST GROUND FLOOR LE VEL r FL 33.90 TO BE PROTECTED IN ACCORDANCE WITH THE CONCRETE. U1/11 PROJECT AVENUE, NOOSAVILLE QLD.4566 c mV cE AUTHORITY RESPONSIBLE FOR THE SERVICE Ph (07) 5455 5604 Fax (07) 5455 5696 IRST FLOOR LEVEL L 37.10 GP2 450Sq PIPE JUNCTION BOX WITH ©” OP UNIT 2 xX pote) U0, PRE-CAST Title: SITE DRAINAGE CARAGE: tL 0.0 GPT 450s eRareD FIELD INLETS Plot A ONSHINE BEACH r CVC) . q F , FIRST FLOOR LEVEL: FFL 36.35 Date: Dec 2013. Drg No. 23360-OW2] * _
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Revised Engineering Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.