Council archive · source document
Revised Engineering Plans · MCU13/0261
Attached to the e-mail MCU13/0261 - Response to Information Request - 5 Stevens Street Sunshine Beach.
Plans and drawings: the text below has words only, no drawings.
Revision | Description NOTES: 1, FOUNDATION TO BE APPROVED FOR A SAFE BEARING CAPACITY OF 100 KPA PRIOR TO CONSTRUCTION; 2. WHERE THE SURFACE SLOPE OF RETAINED MATERIAL IS BETWEEN 10:1 & 4:1 THE WALL BASE DIMENSION IS TO BE INCREASED BY 0.5 METERS. 3. ROCK IS TO BE SOUND AND DURABLE AND AT LEAST 0.5 SQUARE METRES IN PLAN AREA; 4. BACK FILL IS TO BE GRANULAR, FREE DRAINING AND COMPACTED AND ‘A MINIMUM OF 300MM WIDE; ‘5. A CONTINUOUS 100MM DIAMETER SUBSOIL DRAIN WRAPPED IN GEOTEXTILE IS TO BE INSTALLED AT THE REAR OF THE WALL; 6. ROCKS SHALL BE PLACED IN SUCH A MANNER THAT THEY ARE STABLE AND INTERLOCKING & LAID ROUGHLY COURSED AND EMBEDDED ON THEIR BROADEST BASE. 7. WHERE THE WIDTH NOMINATED IS MADE UP WITH A SERIES OF ROCKS, ROCKS SHOULD BE CONCRETE ROUTED TOGETHER TO ENSURE INTERLOCKING CAN OCCUR. DESIGN S.L. B WALL WIDTH DIMENSION (M) 1 2 3.35 0.3.0.5 IF THE SLOPE IS GREATER THAN 10:1 SEE NOTE 2. GROUND LEVEL & - CO DISTANCE GRATED DRAIN RP BOUNDARY KERB LINE NOMINAL GARAGE ~ UNIT 1 B85 Vehicle FFL 30.7 1 in 20 ! in 10 Max. Vehicle fint6 Max. H WALL HEIGHT (m) in 9 May. FFL $0.3 1 in 90 Max. 1 in 20 Mox. GARAGE f UNIT 2 = ROCK SIZE REFER TO NOTES. REFER DRIVEWAY CROSSOVER DETAIL ABOVE WALL DESIGN CHART RL 27.00 V FINISHED G.L GROUND LEVEL a KEYED INTO ROCK 450 KEYED INTO SOIL er REFER Drg OW-3 FOR DRIVE WAY PLAN. 200MM FREE DRAINING BACKFILL WITH GEO FABRIC WRAPPING AGI PIPE TO GPT'S. DRIVE WAY ~ LONGITUDINAL SECTION Scale 1: 100 |____150 THK C20 CONCRETE BED BASE. TYPICAL ROCK WALL GEOMETRY SL82 MESH MIDDLE i KERB LINE CONSTRUCTION NOTES GENERAL: 1. DO NOT SCALE FROM THIS DRAWING. 2. ALL DIMENSIONS IN MILLIMETRES 3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS. 4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE ARCHITECTURAL DRAWINGS ARE TO BE REFERRED TO THE ENGINEER IMMEDIATELY. 5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING SERVICES WITHIN AND ADJACENT THE ALLOTMENT AND SHALL ENSURE THAT ALL NEW 125 THICK DRIVEWAY SLAB WET TOOLED CONTROL JOINT WORKS ARE IN ACCORDANCE WITH THE ATTACHED CRITICAL DEPTH LINE DIAGRAM. FOOTPATHS AND DRIVEWAYS: 1. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL 2. CROSSINGS ARE NOT DESIGNED FOR COMMERCIAL VEHICLES 3. CONCRETE DRIVEWAY TO BE 125mm THK. EXCLUDING ANY FINISHED TREATMENTS, EG. STAMPING 4. CONCRETE SURFACE TOLERANCE +5.0mm OVER 3.0m 5. CONCRETE N25 IN ACCORDANCE WITH AS 1379 AND AS 3600 6. REINFORCEMENT FABRIC TO AS 1304, PLACED CENTRAL SLAB DEPTH. 7. EXPANSION JOINTS TO BE 10mm WIDE WET TOOLED WITH EVERY 2ND MESH WIRE CUT ALONG JOINT. 8. ONE ACCESS POINT PERMITTED FOR EACH ALLOTMENT. 9. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO INSIDE EDGE OF CURVE 10. ALL SERVICES TO BE LOCATED AND PROTECTED AS REQUIRED PRIOR 10 WORK COMMENCING CUT EVERY 2AN WIRE ALONGLINE OF JOINT SAW CUT AND BREAKOUT BACK OF KERB SL72 MESH MIDDLE BARRIER, SEMI-MOUNTABLE, MONTABLE KERB & CHANNEL OR INVERT CROSSING CROSSOVER DETAIL 50MM COMPACTED SAND BED issue ISSUE FOR CONST. DEBUILD T/A SCG CONSULTING ENGINEERS Structural - civil - geotechnical ABN 40 098 481 899 U1/11 PROJECT AVENUE, Ph (07) 5455 5604 NOOSAVILLE QLD.4566 Fax (07) 5455 5696 Title: DRIVE WAY LONGITUDINAL SECTION Project’ 5 Stevens St, SUNSHINE BEACH. Date: Dec 2013. Drg No. 23360-OW4|
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Revised Engineering Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.