Council archive · source document
Planning Report and plans · MCU16/0049
Attached to the e-mail MCU16/0049 & OPW16/0109 38 Elanda Street Sunshine Beach.
Plans and drawings: the text below has words only, no drawings.
Column 1 Column 2 Column 3
Specific Outcomes Probable Solutions (if code assessable) Compliance
b) incorporating an access point from each street,
one for each of the dwelling units
Garages and carports
O33 Garages, carport structures and vehicle S33.1 Garages and carports have a front Complies
manoeuvring areas are designed and sited boundary setback of at least 6m provided that
to— garages may be setback 5.5m from the front
a) provide for resident and visitor parking; boundary where garage doors are staggered 1m
b) visually integrate with the building and to from each other in relation to the frontage
not dominate the street front; AND
c) allow opportunity for landscaping to screen S33.2 Garages present a minimum width to the Two 5.4 metre wide garage doors are proposed.
vehicle parking and manoeuvring areas; streetscape (the total width of garage doors is no The total width exceeds requirements however as
d) minimise the number of driveway accesses; more than 6m or 50% of the frontage width, discussed with staff the garages are staggered
and whichever is the lesser, where the structure faces and provide areas for substantial landscaping to
e) allow safe and efficient access to and the street) AND the streetscape. Appropriate manoeuvring is
egress from the premises. provided and the garages are partially excavated
into the site which reduces their visibility to the
street. The overall small scale of the development
(primarily single storied) ensures that the garages
do not dominate the streetscape.
Pedestrian access is maintained on Elanda Street.
S33.3 Where multiple double garages are included Complies – garages stepped back. This aspect
garages are stepped back a minimum of 600mm was discussed with Council staff who agreed that
from each other, in relation to the frontage or are the
separated by at least 2m; or
S33.4 Garages that are visible from, but do not Not applicable
face the street, include windows or other
articulation and have a 6m vegetated buffer
between the structure and the road frontage.
AND
S33.5 Where located on the major road network or Not applicable
a collector street, vehicles are able to enter and
exit the site in a forward gear through a 3-point
turn maximum;
AND
S33.6 The development provides for shared Complies – one driveway provided
driveways to minimise the number of access
points, except on sites with more than one street
Page 7 Connan & Knight 02024 Elanda Street Sunshine Beach
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Planning Report and plans.pdfRelated documentApplication case desk ↗
Planning Report and plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.