PLANNING ACT – 2016
NOOSA COUNCIL
APPROVED PLAN
Date:
MCU21/0031 1618/12/2020
JUL 2021
ZĞĨĞƌĞŶĐĞEŽ͗ RAB20/0253
This Plan Accompanies the
Concurrence Agency Response
Document Set ID: 21498670
Version: 1, Version Date: 16/06/2021
[OCR of page images]
NOTE:
1. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED
WITH LIFT OFF HINGES & BE FITTED TO ALLOW THE DOOR
TO BE REMOVED WHEN IN THE CLOSED POSITION 6)
2. PROVIDE SMOKE ALARMS IN ACCORDANCE,
WITH THE B.C.A. PART 3.7.2 4
NOTE:
EXISTING REMOVAL DWELLING. ELEVATION KEY
EXISTING PINE TIMBER FRAME.
EXISTING UPPER FLOOR BRACING TO
COMPLY WITH AS 1684.2-2010
| 1300 2250 11055 1435
2250 3550 2510 1500 _ | 3120
75 75 75 {| 75 75
1585 || 4215 2510 885 | 2745 | 2500
4175 75 75 475 4
wo 09.24sw 0906sw lo
ny ~ —_ OOO TT OTT OD ~~
TiS 1 +
3
{oF , °o 2
. I ga | |g
g | Bedroom 2 o
8 3 Bedroom 1 | MN
6 Sok L
N | = Aan
Smok 2
sé iam ® = 3 =
eae = | 2) e
t iN So
8 S Smoke 3 ~
8 : @ 5 o Alarm 2 | a oa
rT Line of existing wall i m NOOSA COUNCIL
remove
a} & APPROVED PLAN
So
| 5 New 100100 hud e MCU21/0031 16 JUL 2021
wo wo 8 -—— New 100x100 hwd posts.
qi a % | positioned over shs ==
° o | columns below. o
New 150x42 LVL 15 3
o | beam over -Continuous. ~ 3
2 2/m12 bolts to each post. =
= ~ [ 1 | ® >=
Remov hi Noosa Plan 2020
‘emove hip roof over.
1585 | 7160 5845 A03
A secondary dwelling:
1 1s eo a) has a maximum gross floor area of 65m?;
6495 | 2645 b) has no more than 2 bedrooms;
75 75 | 100 c) does not occur on any property covered by a Building Unit Plan; and
| 4300 2250 6645 3345 2500 d) does not occur on a property that already contains a dual occupancy or secondary dwelling.
Gross floor area
gross floor area for a building, means the total floor area of all storeys of the building, measured from the
outside of the external walls and the centre of any common walls of the building, other than areas used for—
FLOOR AREAS a) building services, plant or equipment; or
TT b) access between levels; or
LIVING AREA: 65.00 m? c) a ground floor public lobby; or
PORCH AREA: 16.70 m? d) a mall; or
(- > P RO POS E D P LAN DECK AREA: 34.00 m? e) parking, loading or manoeuvring vehicles; or
TOTAL AREA: 115.70 m@ f) unenclosed private balconies, whether roofed or not.
Yo) SCALE -1: 100 .
Noosa Shire Planning Scheme - Definitions
PROJEC
p 4 920655 " PROPOSED SECONDARY DWELLING /"°**
y ™
CLIENT 2020788 Se DaviDwright
LINEA mosses 27 P. & A. SCIVYER ai sai een erate
497 BLACK MOUNTAIN ROAD
ESIGN = PRAFTING
BESIDE RETIN: ne seine ara BLACK MOUNTAIN 03 ph: 07 38882234
and shall not be copied in whole .
or in part without written approval 240 Bruce Hwy Eastern Service Road, Burpengary East
©COPYRIGHT Date 26 OCT. 2020 Scale 1:100 Drawn AJL QBCC:1139817 www.davidwright.com.au
Document Set ID: 21498670
Version: 1, Version Date: 16/06/2021