Original source · versioned page text
RFI - Traffic Engineering Report
Very large file: it may take a few minutes
The original of this document is very large (19.6 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
11 Summary and Conclusions 11.1 Access design and location The proposed access arrangements, with the car park and set down facility access integrated with the existing roundabout at the intersection of Grant Street / Banksia Street and the service vehicle access located off the cul-de-sac at the end of Serenity Close, are considered acceptable for the proposed development. The design of both driveways and access ramps comply with the required standards. 11.2 Car Parking Arrangements The proposed parking supply for the 380 parking spaces exceeds Councils requirements. 11.3 Impact on Surrounding Road Network Assessment of the proposed development indicates that the development will not have a significant impact on the future road network. As such, no further mitigating road works are required. 11.4 Service Vehicle Arrangements Servicing for this development will primarily be facilitated in the designated loading area on the Basement level accessed off Serenity Close. Service vehicle demands for the various uses of the site will be managed in a way to share the use of the loading area,. The largest design vehicle, a 10.7m LRV, can manoeuvre on site in order to enter and exit in a forward gear. Overall, the proposed service vehicle arrangements are considered adequate to meet the needs of the proposed development. 11.5 Active Transport Facilities The current public transport infrastructure and proposed site provisions for pedestrian/bicycle facilities is considered adequate for the development. 11.6 Conclusion Based on the assessment contained within this report, TTM see no traffic engineering reason why the relevant approvals should not be granted. Site: 3-7 Serenity Close, Noosa Heads – Proposed Resort Complex 36 Reference: 22BRT022 RP01_1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.