Original source · versioned page text
Attachment 2 - Hydraulic Plans.pdf
Drainage Plan No:
DO NOT SCALE ANY PART OF THIS DRAWING
ALL DIMENSIONS ARE TO BE TAKEN FROM THE ARCHITECTS DRAWINGS & ON SITE
rev date drawn reason for issue
1 18.03.26 KC PRELIMINARY
7
.6
33
OWNER
SL
5
.4
OWNER
34
SL
5
RPD
.4
34
2
SL 32.9
SL
5
LOT
.4
0
34
SL 32.93 m
.8
32
SL 32.82 m
89
SL
LOCAL AUTHORITY
2.
SL
3
SWMH
SL
SEMH
MAINTAIN CLEARANCE TO
EXISTING SEWER MANHOLE
LOCAL AUTHORITY
PROPERTY ADDRESS
S S
-
S S
ADDRESS
- DEVELOPMENT TYPE
DEV
8
.9
THE DESIGN CONTAINED ON THESE DRAWINGS COMPLIES WITH THE FOLLOWING:
32
DEMOLITION PLAN
SL
· QUEENSLAND PLUMBING & DRAINAGE ACT 2018
SCALE 1:100 · QUEENSLAND PLUMBING & DRAINAGE REGULATION 2019
· QUEENSLAND PLUMBING & WASTE WATER CODE (VERSION 1:2024)
· AS/NZS 3500 - PART 0 - 2021 GLOSSARY OF TERMS
· AS/NZS 3500 - PART 1 - 2021 WATER SERVICES
· AS/NZS 3500 - PART 2 - 2021 SANITARY PLUMBING & DRAINAGE
· AS/NZS 3500 - PART 3 - 2021 STORMWATER DRAINAGE
· AS/NZS 3500 - PART 4 - 2021 HEATED WATER SERVICES
· NCC 2022 VOLUME 1 - BUILDING CODE OF AUSTRALIA
· NCC 2022 VOLUME 3 - PLUMBING CODE OF AUSTRALIA
· AS 2419-1-2021 - FIRE HYDRANT INSTALLATIONS
· AS 2941-2013 - FIXED FIRE PROTECTION INSTALLATION - PUMPSET SYSTEMS
· AS 2441-2005 - INSTALLATION OF FIRE HOSE REELS
LOCATE & CONNECT TO EXISTING BOOSTED FIRE
SERVICE SUPPLYING 'THE RISE' APARTMENTS. Approved: Shane O'Toole
LOCATE & CONNECT TO EXISTING QBCC Number: 1300235
SAWCUT & REINSTATE EXISTING SLAB
150Ø HOUSE DRAIN + WATER SERVICE. IN ACCORDANCE WITH STRUCTURAL scale bar 1:100
ENGINEER'S APPROVAL.
PIPEWORK CROSSES ABOVE GROUND IN 150Ø 0m 1 2 3 4 5 6 7 8
INSTALL NEW 150Ø SINGLE PIPEWORK ROLL GROOVED STEEL. PROVIDE BRACKETS
7
.6
TESTABLE CHECK VALVE RISES UP TO SUPPORT & PROTECT PIPEWORK.
33
HD
HD
AFTER EXISTING FIRE
PRELIMINARY
SL
HD
HD
5
SERVICE WATER METER
.4
34
180Ø PE100 SDR11 FEED consulting engineer
SL
HD
5
& BOOSTED PIPEWORK
.4
RELOCATED
34
2 RUN IN-GROUND.
SL 32.9 ATTACK HYDRANT
SL
5
.4
0
EXISTING FIRE
34
SL 32.93 m
.8
NEW ALINE PACKAGED FIRE PUMP,
32
SL 32.82 m
89
SERVICE
SL
CAPABLE OF 10L/s @ 70m HEAD IN
2.
SL
WATER METER
3
ACCORDANCE WITH AS.2419.1 & AS.2941.
SWMH
SL
HOSE TAP OVER
SEMH
MAINTAIN CLEARANCE TO RELOCATED ORG NEW 150Ø BOOSTER ASSEMBLY IN
EXISTING SEWER MANHOLE TO CHARGE ACCORDANCE WITH AS.2419.1, INCLUDING
150
W
PROPRIETARY CABINET & CONCRETE PLINTH.
100Ø UPVC 1.65% +
S S
20Ø WATER SERVICE
W
RUN IN GROUND Cushway Blackford & Associates Pty Ltd
ABN 23 010 522 988
150
100Ø UPVC DRAIN P 07 3896 1100
W
E [email protected]
TO KERB & CHANNEL
5 Trafalgar Street, Woolloongabba QLD 4102
PO Box 1517, Coorparoo DC QLD 4151
8
.9
architect
32
PROPOSED PLAN
SL
SCALE 1:100
NOOSA DRIVE
Cayas
+ Ward
Suite 2, 19-25 Musk Avenue, Kelvin Grove. PO Box 360, Wilston Q 4051
p 07 3356 6100 e [email protected]
NSW Nominated Architect: Kimberley James Garton 8891
project
NOOSA REEF HOTEL
19 NOOSA DR, NOOSA HEADS,
QLD 4567
drawing title
DEMOLITION & PROPOSED
DETAIL PLAN
HYDRAULIC SERVICES
scale designed drawn
1:100 @ A1 SD BJS
project number drawing number revision
24-439 H11 1
[OCR of page images]
PLOTTED: kunalc 18 Mar, 2026 — 2:21pm
FILE: K:\PROJECTS\24—439\DWGS\HYD\24—439_H11.dwg
-———— MAINTAIN CLEARANCE TO |
~/ EXISTING SEWER MANHOLE - - —|4 — — — oe ee
DEMOLITION PLAN
SCALE 1:100
LOCATE & CONNECT TO EXISTING BOOSTED FIRE
SERVICE SUPPLYING 'THE RISE' APARTMENTS.
SAWCUT & REINSTATE EXISTING SLAB
IN ACCORDANCE WITH STRUCTURAL
ENGINEER'S APPROVAL.
LOCATE & CONNECT TO EXISTING
150@ HOUSE DRAIN + WATER SERVICE.
+-——
PIPEWORK CROSSES ABOVE GROUND IN 1508
INSTALL NEW 1502 SINGL —— _ PIPEWORK | ROLL GROOVED STEEL. PROVIDE BRACKETS
TESTABLE CHECK VALVE ||| — — | rises UP | TO SUPPORT & PROTECT PIPEWORK.
AFTER EXISTING FIRE I; SSS =~! |
SERVICE WATER METER —~ — Ne ~~ A ;
|| | 1800 PE100 SDR11 FEED Neo [ OO
c= | - & BOOSTED PIPEWORK RELOCATED ~ |] —
: ° } D, ATTACK HYDRANT | —
EXISTING FIRE | ¥ “++ NEW ALINE PACKAGED FIRE PUMP, !
WER METER | 0 CAPABLE OF 10L/s @ 70m HEAD IN ||
ul ACCORDANCE WITH AS.2419.1 & AS.2041. HOSE TAP OVER I
if MAINTAIN CLEARANCE TO | RELOCATED ORG Sete |—~— NEW 1500 BOOSTER ASSEMBLY IN
ep | SSCS puma ner rete
; | | / 1000 UPVC 1.65% +
te 200 WATER SERVICE
U— s ——= tg J aS a ee == = =~ ~~ ~~ ~~ TT ~~ ~~ ~~ —
RUN IN GROUND —
dl
Pe 1002 UPVC DRAIN
~~ a) ~~ TO KERB & CHANNEL ~~ ~~ ~~ = 5 nn nnn rrr FO -
~~ SCALET:100
NOOSA DRIVE
DO NOT SCALE ANY PART OF THIS DRAWING
ALL DIMENSIONS ARE TO BE TAKEN FROM THE ARCHITECTS DRAWINGS & ON SITE
rev | date | drawn | reason for issue
1 | 18.03.26 | KC | PRELIMINARY
OWNER
OWNER
RPD
LOT
LOCAL AUTHORITY
LOCAL AUTHORITY
PROPERTY ADDRESS
ADDRESS
DEVELOPMENT TYPE
DEV
THE DESIGN CONTAINED ON THESE DRAWINGS COMPLIES WITH THE FOLLOWING:
QUEENSLAND PLUMBING & DRAINAGE ACT 2018
QUEENSLAND PLUMBING & DRAINAGE REGULATION 2019
QUEENSLAND PLUMBING & WASTE WATER CODE (VERSION 1:2024)
ASINZS 3500 - PART 0 - 2021 GLOSSARY OF TERMS
ASINZS 3500 - PART 1 - 2021 WATER SERVICES
ASINZS 3500 - PART 2 - 2021 SANITARY PLUMBING & DRAINAGE
ASINZS 3500 - PART 3 - 2021 STORMWATER DRAINAGE
ASINZS 3500 - PART 4 - 2021 HEATED WATER SERVICES
NCC 2022 VOLUME 1 - BUILDING CODE OF AUSTRALIA
NCC 2022 VOLUME 3 - PLUMBING CODE OF AUSTRALIA
AS 2419-1-2021 - FIRE HYDRANT INSTALLATIONS
AS 2941-2013 - FIXED FIRE PROTECTION INSTALLATION - PUMPSET SYSTEMS
AS 2441-2005 - INSTALLATION OF FIRE HOSE REELS
ey
Approved: Shane O'Toole
QBCC Number: 1300235
scale bar 1:100
Om 1 2 3 4 5 6 7 8
Wu! | | | | | | J
PRELIMINARY
Tl] cusHWAY
BLACKFORD
CONSULTING ENGINEERS
Cushway Blackford & Associates Pty Ltd
ABN 23 010 522 988
P 07 3896 1100
E [email protected]
5 Trafalgar Street, Woolloongabba QLD 4102
PO Box 1517, Coorparoo DC QLD 4151
Cayas
+Ward
Suite 2, 19-25 Musk Avenue, Kelvin Grove. PO Box 360, Wilston Q 4051
p 07 3356 6100 e [email protected]
NSW Nominated Architect: Kimberley James Garton 8891
project
NOOSA REEF HOTEL
19 NOOSA DR, NOOSA HEADS,
QLD 4567
drawing title
DEMOLITION & PROPOSED
DETAIL PLAN
HYDRAULIC SERVICES
scale designed = drawn
1:100 @ Al SD BJS
project number drawing number revision
24-439 H11 1
Preview the original
The page text is free to read. Previews and downloads of original files need an account.
Log in to previewLog in to download the original (Attachment 2 - Hydraulic Plans.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.