-4- Comment: The Design Note prepared by Cardno Eppell Olsen attached in Appendix C demonstrates how safe pedestrian access is proposed to each of the Industrial Units. This includes provision of a pedestrian path around the entire site at a width of 1.2m which is the Australian Standard. “Issue 7.6 To prevent vehicles from encroaching over proposed landscaped areas, wheel stops will be necessary to most of the proposed car parking spaces and these wheel stops should be shown on the amended proposal plan. __ pe Comment: The Design Note prepared by Cardno Eppell Olsen attached in Appendix C details the circumstances under AS2890.1 in which wheel stops should be provided. Encroachment over landscaped areas is not one of these circumstances and as such wheel stops are not considered necessary. "Issue 7.7 ~ 7 1 Staff car park spaces on a development of this scale, with 44 different Units/tenancies, is‘ * inappropriate and will not function adequately. In accordance with AS2890.1, staff car parks cannot | be intermingled across the development but instead need to be kept together if they are to work | | ' properly. This however will be difficult to achieve in practice on this development due to the size of | the site. As such all spaces on site should be sized as standard spaces 2.6m wide x 5.4m long, ® unless the space is obstructed by an adjacent wall or fence, in which case the space will need to be | ‘at least 300mm wider.to allow access and room for.car,doors to open... _ Comment: The Design Note prepared by Cardno Eppell Olsen attached in Appendix C confirms that the amended carparking provision shown on the proposal plan is acceptable and appropriate for the use. (Issue 7.8 ' ' Provide at least 4-disabled carpark spaces (evenly distributed across the development to maximises .their usage) each with a minimum dimension of, 3.2m wide x 5.4m long. Comment: The Design Note prepared by Cardno Eppell Olsen attached in Appendix C confirms that only 2 disabled car spaces are required under AS2890.1. 3 disabled car spaces are proposed which is above standard. “Issue 8 Demonstrate that the car park area (including all loading areas, manoeuvring areas, and driveways) | I ‘comply with Australian Standard AS2890.2 — Commercial Vehicle Facilities. The issues addressed , Shall include: | eh ee ee Comment: The Design Note prepared by Cardno Eppell Olsen attached in Appendix C confirms that the carpark area complies with AS2890.2. Issue 8.1 Te : Cs Demonstrate that a 19m-semi trailer is capable of entering and leaving the site in a forward gear | with provision for such vehicle to be safely parked for loading and/or unloading without restricting , _the operation of the industrial facility. In this regard a designated semi trailer loading area needs to” be provided and this should be shown on the amended proposal plans along with the swept path of . this vehicle.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0738 - Response to Information Request [As Published]Related documentApplication case desk ↗
About this file
- File size
- 5.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.