Eumundi Noosa Road Townhouses - TH01 - TH04 SECTIONS
                                                                                                                                                                                                     8m height limit
                                        RS1


                                                                                                                                                                           RS1                                                                                  RS1




         DECK          DINING 2,600
                                                                         DESK

                                                                                                     BTHRM                         BED 1                                                              BED 1            BTHRM
                                                                                                                                                                                                                                                 DINING               LIVING




                                                                                                                                                                                                                                                      2,550
                                                                                                 2,550




                                                                                                                                                                               2,550
         BAL1        +18.75



                                                                                                                                                                                            +17.85                                                                +17.90
                              2,850




                                       BED 1                         BTHRM                                                         DINING                   LIVING      LIVING                            DINING
                                                                                                                                                                                                                                         BTHRM                        BED 1




                                                                                                                                                                                                                                                      2,850
                                                                                                 2,850




                                                                                                                                                                               2,850
                     +15.90



                                                                                                                                                                                            +15.00                                                                +15.05

                   INDICATIVE NATURAL GROUND LINE
                        DASHED - REFER NCLS SURVEY                                                                                                                        NEW RLS - REFER CIVIL                                            FILL - REFER CIVIL




 01                 A-A TH01 - TH04                            1:100
                                                                                                                             8m height limit
                                                                                                                                                               2,000
                                                                                                                                                             Setback
                                                                                                 6° pitch
                                      5° pitch




                                                     BTHRM                       ROBE                            ENSUITE
                                                                                                         2,550




                                                                                                                    +17.85




                                                 P'DER          KITCHEN                                          DINING

                                                                                                                                                                                                                                                                           FINISHES LEGEND
       DRIVEWAY
                                                                                                         2,850




                                                                                                                                   TERRACE

                                                                                                                    +15.00
                                                                                                                                                                                                                                                                           AWN             Awning/Hood
                                                                                                                                           T1
                                                                                                                                                                                                                                                                           AG              Acoustic Glass
                                                                                                                                                                                                                                                                           BAL1            Aluminium Batten Balustrade
                                                                                                                                                                                                                                                                           BAL2            Aluminium Angled Batten Fixed Screen
                                                                                                                                                                                                                                                                           FC1             Hardies Axon FC Cladding
      INDICATIVE NATURAL GROUND LINE                                           NEW RLS - REFER CIVIL                                   FILL - REFER CIVIL                                                                                                                  FC2             Hardies Easylap
           DASHED - REFER NCLS SURVEY                                                                                                                                                                                                                                      FC3             6mm FC with Aluminium Coverstrips - Paint Finish
                                                                                                                                                                                                                                                                           FC4             Axon - Timber Look Paint Finish
                                                                                                                                                                                                                                                                           RBW             Rendered Blockwork

 02           B-B TH01 - TH04 1:100
                                                                                                                                                                                                                                                                           RS1             Roof Sheet - CB Spandek
                                                                                                                                                                                                                                                                           SE              Shotedge HWD decking
                                                                                                                                                                                                                                                                           TL1             External Tile - 400 x 400
                                                                                                                                                                                                                                                                           WB              Hardies Sycon Linea Weatherboard

Rev    Date       Description
                                                                                                                             B L A C K                                                     Project:                                  Drawing Title:                               Project No.          Drawn By               Drawing No.
                                                         Use     figured    dimensions     in
                                                         preference to scale. All dimensions
                                                                                                                                                       Contact information:
B
C
       18/06/2021 Design For Approval
       16/09/2021 Revised plans
                                                         to be varified and checked on site.
                                                         These        designs,      drawings,
                                                                                                                                                       PO Box 781 Tewantin Q 4565          Eumundi Noosa Road                        TH01 - TH04 SECTIONS                         202144               PT                     DA.16
                                                                                                                                                       Architect Registration # 5386 QLD
                                                                                                                             W O O D                                                       Townhouses
                                                         specifications and the copyright
D      08/12/2021 RFI Response                           thereof are the property of                                                                   Ph: 0416 037 424
E      25/01/2022 RFI Response                           Blackwood and must not be used,
                                                                                                                                                       [email protected]     89-93 Eumundi Noosa Road Noosaville QLD   Scale                                        Date                 Project Stage          Revision
                                                         retained or copied without the
F      2/03/2022 RFI Response                            written authority of Blackwood.        a r c h i t e c t u r e            &   d e s i g n     www.blackwoodarchitecture.com.au                                              1:100, 1:50 @ A3                             2/03/2022            RFI Response           F

Used in these records

About this file

File size
28.8 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Eumundi Noosa Road Townhouses - REV F - RFIs - Received 3.3.22.pdf · 28.8 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.