              POLLUTANT / ISSUE                  MINIMAL MEAN ANNUAL LOAD REDUCTIONS

          Total Suspended Solids (TSS)                                    80%

             Total Phosphorous (TP)                                       60%

               Total Nitrogen (TN)                                        45%

              Gross Pollutants (GP)                                       90%


5.3.2    Sources of Contaminants
Gross Pollutants

Gross pollutants include litter, grit and heavier sediments which can be mobilised from within or from
neighbouring sites.

Potential Causes

         •      Unsecured refuse areas.
         •      Un-landscaped areas prone to stormwater scour.
         •      Insufficient drainage for surface runoff from within the site.
         •      Wind Bourne transportation.



Mitigating Measures

         •      Well established refuse areas with ample storage bins. Fenced off where deemed
                necessary.
         •      Provision of ample litter bins across the commercial footprints of the site. Particularly in
                any outdoor dining or areas of congregation.
         •      Promotion of stormwater surface runoff through landscaped areas or similar sediment
                buffering strips/traps.
         •      Provide stormwater pits outside paved areas that receive runoff from areas prone to gross
                pollutants with surrounding buffering measures, such as stone pitching.
         •      Provide gross pollutant inserts into stormwater pits within paved areas that receive runoff
                from areas prone to gross pollutants.

Hydrocarbon Runoff:

Hydrocarbons can be mobilised and transported in stormwater runoff from the site. This can contaminate
stormwater runoff compromising Water Quality Objectives.


SCG Consulting Engineers                    Page 11                              SCG Ref: 33132(SWMP).RevC
Log in to download the original file

SWMP change reps.pdf · 23.2 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.