1.0      INTRODUCTION


SCG Consulting Engineers have been commissioned by Capital Prudential to complete a Stormwater
Management Plan (SWMP) for a residential development at Lots 75-77 RP 71151 & Lot 3 SP 208257,
79-83 Eumundi Noosa Road & 26 Headland Drive, Noosaville.

The proposed development involves the construction of 38 townhouse/apartment dwellings. The
objective of this (SWMP) is to demonstrate that the following measures will be incorporated into the
design and construction of the development:

         •      Maintain stormwater quality – Protect receiving waters (during and post construction)
         •      Manage stormwater peak flow rates of runoff and existing flow path characteristics
         •      Protect against flooding
         •      Adopt Water Sensitive Urban Design (WSUD) principles throughout
         •      Implement Stormwater Harvesting and re-use for landscaping.



This report should be read in conjunction with our detailed site stormwater management plans
(Appendix D) Drawing No. SCG 33132 – SW1.1, SW1.2 & SW1.3 & SW1.4

The proposed development has been assessed against the following guidelines and planning documents:

         •      Queensland Urban Drainage Manual 2017 (QUDM)
         •      Water Sensitive Urban Design (WSUD) – Technical Design, Guidelines for South East
                Queensland
         •      Noosa Plan 2020
         •      AS/NZS 3500.3:2018 – Plumbing and Drainage Part 3 – Stormwater Drainage
         •      State Planning Policy 2017
         •      Sunshine Coast Stormwater Management Guidelines VI - 2020.
         •      QDC MP1.4 – Rainwater Tanks & Other Supplementary Water Supply Systems
         •      Water by design Stormwater Harvesting Guidelines




SCG Consulting Engineers                     Page 3                         SCG Ref: 33132(SWMP).RevC
Log in to download the original file

SWMP change reps.pdf · 23.2 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.