2. Provide a detailed site survey, including the access driveway, prepared by a qualified surveyor
that includes natural surface levels to AHD. The plan should also identify the surface type and
extent of the access driveway.
3. The Planning Scheme supports not more than one dwelling house on an allotment. The Site
Plan SK 02.01 and ‘Shack’ Floor Plan SK 03.03 submitted with the application show one large
dwelling house and a separate self-contained smaller dwelling house. Please advise of the
intentions for the use of the smaller dwelling. It is noted that the smaller dwelling house is
located within the Open Space zone, which is inconsistent with the intent of the zone.
4. Provide a planning assessment against the relevant objectives of the strategic plan that
demonstrate the development does not impact on the environmental values of the site and
surrounding area and address the following:
4.1. The potential impacts of the development on the flora, fauna and habitat values of the
site and provide measures to mitigate or minimise negative impacts on the ascribed
values. Please refer to PSP 18 Ecological Assessment Guidelines for Council's
preferred format.
4.2. The proposed tennis court and smaller dwelling house is located in an area identified
with high biodiversity values.
4.3. Provide details of the extent of natural vegetation buffering proposed to be retained to
the adjoining National Park and Open Space on and adjacent to the site.
5. The proposed site is located within an identified Sand Dune Problem Area and therefore the
removal of vegetation and earthworks raises concerns with respect to the stability of the
existing natural landform and that of adjoining properties.
5.1. Provide plans and supporting information detailing the extent of vegetation to be
removed, the proposed method of disposal and the steps to be taken to remediate any
adverse impact on the natural landform and the adjoining properties caused by such
action.
5.2. Please provide a report from a suitably qualified geotechnical engineer that addresses
the stability issues and make recommendations with regard to foundations, stormwater
disposal elements and construction methods to ensure the stability of the existing
natural landform and the adjoining properties.
6. It is noted that the subject site is to connect to Council’s sewer mains via a pump up
connection. Please provide a Water Management Plan which includes detail of the necessary
elements of the sewer pumping system required for all floors of the main building, the “shack”
and any other serviced areas. The detail is to include pump wells, holding tanks, storage
capacities (12 hours between alarm and overflow), alarms, overflow, and odour control during
occupant absences, etc. Please indicate on the plans the location of the various elements. For
any advice regarding Council’s requirements for a pumping system please contact Council’s
Sewer Section on 54495288.
7. Council has concerns with how the development will control the impacts of surface runoff from
the adjoining upstream properties and the runoff generated by the various parts of the
development. Please provide a Stormwater drainage plan for the proposed development
indicating the various elements, pits, pipes, tanks and any other structures to be utilised to
control and dispose of stormwater runoff. The stormwater design shall also address the runoff
from the various parts of the access driveway and the vehicle manoeuvring area. The
stormwater drainage design shall be prepared by a Professional Engineer who is registered
with the Board of Professional Engineers of Queensland and in accordance with Council’s
Planning Scheme Policy 5 – Engineering Design Standards – Roads, Drainage and
Earthworks.
Under the provisions of the Integrated Planning Act 1997, you have three options available in
response to this Information Request. You may give the assessment manager (in this instance
Council) and each referral agency (if any):
1. all of the information requested; or
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Request for Further Information - 010.2008.00000169.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 14 KB (small file)
- File type
No other editions are linked here.