Council archive · source document
22.003_The Peninsula_Issue A_08Feb22(3) · MCU22/0085
Attached to the e-mail Combined Application MCU22/0085 & OPW22/0139 - DA Form 1 - Plans - Owners Consent - Form 15 - 63 the Peninsula Noosaville - Signed.
drawing index
01 SITE PLAN
02 FLOOR PLAN, FLOOR FRAMING PLAN & TYPICAL SECTION
Project: NEW JETTY
Client: JIM HUGHES
N o 9 W I L L S A V E N U E . G O L D E N B E A C H . Q L D . 4551
Address: No. 65 THE PENINSULA, NOOSAVILLE Q 4566 0409 612 231 | [email protected]
WWW.KUNKELBUILDINGDESIGN.COM.AU
QBCC Lic No 1136721
Lot 290 ON RP856192 DRAWING NAME REV DATE
COVER SHEET A 08/02/22
A3
DESIGNER PROJECT NO
SD KUNKEL 22.003
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 pages
Page 2
notes
1. Survey information to be confirmed by Licensed
Surveyor prior to construction. Where property
boundary locations are not clear, the contractor shall
organise an identification survey to locate required
boundaries .
2. Extent of site earthworks to be confirmed by
engineer &/or contractor on site prior to construction.
3. Contractor to confirm siting & orientation prior to
setout. Location of pontoon & pontoon setout to be
carried out by Licensed Surveyor.
4. All services to be located on site by contractor prior
to construction.
5. Do not scale off drawings, use figured dimensions
only. Any dimensions not nominated must be referred to
the Designer for confirmation. Contractor shall verify all
dimensions on site prior to construction.
8000 6. Pontoons, gangway, connections & walkway footing
to detail by others.
44.000m 24°45'0" Projected boundary property details
No. 65 The Peninsula
Noosaville QLD 4566
the peninsula
4000
4000
Noosa Shire Council
294°45'0"
Parish - Weyba
proposed
County - March
Lot 290 on RP856192
jetty
Site Area - 914m²
Site Coverage - N/A
114°45'0"
Zone - Low Density Residential
Overlays - Acid Sulphate Soils
- Flood Hazard
canal
13.500m
16000
21.500m
13500
11
.31
4m
24
9°4
5'0
"
36.000m 204°45'0" Projected boundary
signatures
owner/s
site plan
1 1 : 200
builder
DESIGNER CHECKER WIND CATEGORY CLIENT PROJECT DRAWING NAME SHEET NO REV PROJECT NO
N o 9 W I L L S A V E N U E . G O L D E N B E A C H . Q L D . 4551
0409 612 231 | WWW.KUNKELBUILDINGDESIGN.COM.AU N ORT
H SDK SDK N3 JIM HUGHES NEW JETTY
No. 65 THE PENINSULA, NOOSAVILLE Q 4566
SITE PLAN 01
SHEETS IN SET
A 22.003
SCALE
A3
QBCC Lic No 1136721 REV DATE DRAWN ISSUE
A 08/02/22 SDK CONSTRUCTION ISSUE Lot 290 ON RP856192 2 1 : 200
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies
Page 3
Boundary line
Floor joists site welded to
5000 headstocks to engineers detail
200 200 200x50x3mm aluminium
floor joists @ 450 crs max.
70x45 kick rails - 22mm accoya timber or
200
50x50 shs handrail H4 equivalent decking over
site welded Do not fix jetty to
1000
1000
revetment wall 2/152x62x8mm structural
70x45 kick rail 'c' channel headstocks per pile
250mm deep fascia to perimeter
22mm accoya timber or Headstocks to piles to
equivalent decking Existing revetment wall engineers detail
250mm deep fascia
315 dia. pvc insitu piles
handrail detail to engineers details
3 1 : 50 100x75 composite fenders
section
4 1 : 50
Boundary Boundary
200x50x3mm aluminium 2/152x62x8mm structural
floor joists @ 450mm crs max. 'c' channel headstocks per pile
1500 3250 3250 1000 3125 3125 750
100x75 composite Do not fix jetty 100x75 composite
70x45 kick rails fender posts to revetment wall fender posts
750
750
Do not fix jetty notes
jetty
1500
2000
to revetment wall 1. Contractor to confirm exact siting and orientation
750
prior to construction setout.
4000
2500
2. All building setout & confirmation of setbacks &
Rigid handrail to 250mm deep fascia height to be carried out by a Licensed Surveyor.
comply with Noosa 22mm accoya timber or
2500
Shire Council regulations 3. Do not scale off drawings, use figured dimensions
2000
H4 equivalent decking over only. Any dimensions not nominated must be referred to
Joists to butt into headstocks the Designer for confirmation. Contractor shall verify all
750
dimensions on site prior to construction.
with site welded connection
315 dia. pvc insitu piles 4. Levels & services locations to be confirmed prior to
5000 1500 1500 1875 1250 construction.
to engineers detail
5. Termite protection to be provided in accordance with
8000 750 750 clause 3.1.4 of the BCA (QLD variation) & AS3660.1.
Contractor to provide protection information for building
development application.
Boundary
Boundary
legend
Denotes dimension to centre line
aluminium framing sizes to engineers Denotes dimension to outside face
design & detail
signatures
owner/s
floor plan floor framing & footing plan
1 1 : 100
2 1 : 100
builder
DESIGNER CHECKER WIND CATEGORY CLIENT PROJECT DRAWING NAME SHEET NO REV PROJECT NO
N o 9 W I L L S A V E N U E . G O L D E N B E A C H . Q L D . 4551
0409 612 231 | WWW.KUNKELBUILDINGDESIGN.COM.AU N ORT
H SDK SDK N3 JIM HUGHES NEW JETTY
No. 65 THE PENINSULA, NOOSAVILLE Q 4566
FLOOR PLAN, FLOOR FRAMING PLAN &
TYPICAL SECTION
02
SHEETS IN SET
A 22.003
SCALE
A3
QBCC Lic No 1136721 REV DATE DRAWN ISSUE
A 08/02/22 SDK CONSTRUCTION ISSUE Lot 290 ON RP856192 2 As indicated
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies
Used in these records
22.003_The Peninsula_Issue A_08Feb22(3).pdfRelated documentApplication case desk ↗
About this file
- File size
- 352 KB (small file)
- File type
No other editions are linked here.