Council archive · source document
Acoustic Report · MCU15/0122
Attached to the e-mail MCU15/0122 Development Application- Acoustic report Email 4 of 5.
Proposed Medical Centre, Noosaville
3 Measurements
Noise measurements were carried out at the site from 1 September 2015 to 8
December 2015 at the location shown in Figure 3.
The measurements were carried out using a Rion NL-21 (serial no. 351) recording
“fast” response A-weighted sound levels at 15-minute intervals, with the
microphone at a height of approximately 1.2 m. Weather data for the duration of
the survey was obtained from the Bureau of Meteorology automatic weather
station at Noosa, and conditions were generally fine and suitable for noise
monitoring. The instrument was checked for calibration prior to and post-
measurement using a 94 dB acoustic signal at 1000 Hz, and drift in calibration was
nil.
The site was attended for a 15-minute period on 8 September 2015 to gain a
subjective assessment of the acoustic environment and to verify that the sound
measurement instrumentation was functioning correctly.
Notes from the attended measurements are provided in Table 1, and a summary
of the logged data over the week is provided in Table 2. A graphical representation
of the measurement data is provided in Appendix B.
Logger
location
Figure 3: Noise Logger Location – Goodchap Street, Noosaville
Table 1 Attended Noise Measurement Notes
Source Sound Level
Road traffic 50-60 dB(A)
Birds 48-55 dB(A)
General background ~42 dB(A)
www.roadpro.net.au 5 November 2015 Page 4 of 8
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Acoustic Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 8.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.