Updated Architectural Plans08.07.2021
Original PDF page 7, section 2. The text section number identifies this passage in the reader.
12
SMALL CAR
SMALL CAR
B3
d to
1,475.77 m2
Small Car
VISITOR
VISITOR
AS2890.1
AS2890.1
Small Car
Lockers
Voi
B4
P12
P20
STORE STORE STORE STORE STORE STORE STORE B5
Unit 19 Unit 18 Unit 17 Unit 16 Unit 15 Unit 14 Unit 13 Electrical B6
18.89m3 13.85m3 13.85m3 13.09m3 13.09m3 13.85m3 13.03m3 Store
B7
D.P
D.P
RESERVED
user Class 3
'LOGO'
AS2890.1
P3
user Class 1A
user Class 1A
AS2890.1
AS2890.1
UNIT 12
UNIT 14
AS2890.1 AS2890.1 AS2890.1 AS2890.1 AS2890.1 AS2890.1 AS2890.1 AS2890.1
SDA
SDA
P13
P21
D.P
D.P D.P
D.P
user Class 1A user Class 1A user Class 3 user Class 1A user Class 3 user Class 3 user Class 3 user Class 4
fall to civil engineers levels
PWD Visitor PWD Shared Zone
RESERVED
user Class 3
AS2890.1
'LOGO'
P4
BIO RETENTION
'LOGO' 'LOGO' 'LOGO' 'LOGO' BASIN AS PER
user Class 1A
user Class 1A
CIVIL ENGINEER
AS2890.1
AS2890.1
UNIT 13
UNIT 15
BO
SDA
SDA
P14
P22
UNIT 18 UNIT 17 RESERVED UNIT 16 RESERVED RESERVED RESERVED SPECIFICATIONS
P25
P32 P31 P30 P29 P28 P27 P26
RESERVED
6
user Class 3
'LOGO'
AS2890.1
P5
fall to civil
Residential Building Above
Residential Building Above
Residential Building Above
Residential Building Above
engineers
levels
RESERVED
B99
user Class 3
'LOGO'
AS2890.1
P6
D.P
D.P
P33
fall to civil engineers levels
COMMERCIAL COMMERCIAL
BO
COMMERCIAL COMMERCIAL
ARCHICOLOGY P/L
7
architecture
about people
Pump Room
Fire Hydrant
51.34 m2 40.42 m2 51.97 m2 42.00 m2 10.85 m2
PWD Visitor PWD Shared Zone UNISEX
12.21PWD
m2
AS2890.1
user Class 4 AMENITIES ph 5446 3113
D.P
Po Box 579 Coolum Beach 4573
D.P
D.P
D.P
RL 5.7
D.P
The builder shall check and verify all dimensions and
D.P
F. H. R.
Commercial Signage verify any errors and omissions to the architect. Do not
24.00 m2 5 scale off drawings. Drawings shall not be issued for
construction purposes until issued by the Architect for
CARPARK
RL's and falls to civil engineers levels
construction. In the first instance contact :
ENERGEX - PMT Brigade Booster Mr Adrian Just on 0412 117772
RL's and falls to civil engineers levels
EXIT
Pad Mount Cabinet
Transformer
CARPARK
Client Name
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
ENTRY
Commercial Signage
Meter Assembly
sewer line Project Name
Water / Fire
Tewantin 40 x 40
SCHEME B : 2 LEVELS : 19 UNITS
30 & 32 Doonella St, Tewantin QLD, 4566
6 PEDESTRIAN
5
ENTRY
Drawing Title:
Areas - Ground / Carpark
existing existing
existing tree
tree tree
Scale: As shown Date: 2020
Status: SD Checked By: ACJ
Ground / Carpark Plan Project No: Drawing No.:
1
1:100 20531 SD07
Plot Date: 8/07/2021
See the original