Original source · versioned page text
MCU14/0056 - Town Planning Report
town planning
report
Visitor Accommodation Code
Specific Outcomes Probable solutions (if code assessable)
Mitigation of noise impacts S5.1 Visitor accommodation is not located along parts of the Complies- Myall Street and Ferrells Road are
O5 Development is designed and sited to avoid adverse noise major road network which have a legal speed limit of 60km /hour streets.
impacts associated with neighbouring noise sources by— 80km/hr or above, and is setback 40m from the North Coast
a) locating the use away from major noise sources such as busy railway line.
roads or rail corridors: or
b) applying appropriate noise attenuation measures into the
development.
Ancillary recreation uses S6.1 If the use involves ancillary use of outdoor courts N/A
O6 Ancillary recreation uses, such as outdoor tennis courts and half including tennis courts, half courts and netball courts—the
netball courts, do not have an adverse effect on the amenity use complies with the requirements in Section 2 of PSP8
enjoyed by users of adjacent or nearby premises nor do they cause Tennis and Other Courts; AND
unreasonable disturbance to local fauna through light emissions,
S6.2 A 3m wide landscaped buffer is provided between the N/A
by ensuring that lighting devices are limited to those designed
tennis court and any boundary of the site; AND
and installed to:
a) minimise light spillage on neighbouring premises; S6.3 Any lit tennis court or sports court is located at least N/A
b) preserve an acceptable degree of lighting amenity at the 60m from the external wall of an existing or approved
neighbouring premises; residential dwelling on an adjacent or nearby lot (as
c) provide covers or shading around lights; measured from the centre line of the court); AND
d) direct lights downwards;
S6.4 The vertical illumination resulting from direct, reflected N/A
e) position lights away from possibly affected areas; and
or other incidental light emanating from the site does not
f) enable brightness of lights to be adjusted to low levels.
exceed 8 lux when measured at any point 1.5m outside the
boundary and at any level from ground level upward; AND
AND
O7 Noise originating from the use of the tennis court does not S6.5 Any flood lighting is restricted to the types that give no N/A
have a detrimental effect on the amenity of the area or cause upward component of light where mounted horizontally (i.e.
nuisance to neighbouring residents. a full cut off luminare).
S7.1 The court is not used between the hours of 10:00pm N/A
saunders havill group page 62 Job 6520
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.