Original source · versioned page text
MCU14/0056 - Town Planning Report
town planning
report
Landscaping Code
Specific Outcomes Acceptable Solutions/Probable Solutions Compliance
Services and utilities S7.1 Plant species used in landscaping adjacent to substations, or Complies with the Acceptable Solutions
O7 All landscaping works maintain adequate safe distance adjacent to or on electricity transmission line easements, are less than The proposal will comply with the acceptable
from services and utilities including substations, overhead 4m high at maturity and do not encroach within 3m of a substation
solution of S7.1 because all trees and large
boundary; OR
powerlines, power poles and transformers, street lamps, shrubs under power lines shall be selected
stormwater catchment pits, and underground services and from the Energex safe trees guidelines.
utilities.
S7.2 For trees higher than 4m, trees are planted at a distance from any Complies with the Acceptable Solutions
Figure 14-17 part of an electricity transmission line at least equal to the expected The proposal will comply with the acceptable
height of the tree at maturity (see Figure 14-17); AND
solution of S7.2 because all trees and large
shrubs under power lines shall be selected
from the Energex safe trees guidelines.
S7.3 For power lines that connect to a premises, the height of plant Complies with the Acceptable Solutions
species at maturity provides for a 2m clearance below the power line; The proposal will comply with the acceptable
(see Figure 14-18)
solution of S7.3 because all trees and large
AND
shrubs under power lines shall be selected
from the Energex safe trees guidelines.
Figure 14-18 S7.4 Trees and large scrubs are located a minimum of— Complies with the Acceptable Solutions
a) 5m from electricity poles and pillars; The proposal will comply with the acceptable
b) 4m from street lamps;
solution of S7.4 because all trees and large
c) 2m from stormwater catchment pits; and
d) 2m from underground services and utilities; AND shrubs will be located at the acceptable
design standard limits as noted in S7.4.
S7.5 Plants are located to enable tradespersons to access, view and Complies with the Acceptable Solutions
inspect service meters, such as water and electricity meters; AND The proposal will comply with the acceptable
solution of S7.4 because all plants will be kept
at an acceptable distance away from the
services and their meters to maintain easy
access.
saunders havill group page 74 Job 6520
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.