Council archive · source document
RFI - Attachment D - Amended Engineering Drawings · 132008.1128.04
Original PDF page 7, section 1. The text section number identifies this passage in the reader.
4.00
FIRE TRAIL CARPARKING ENTRANCE SERVICE YARD
RP BDY
RP BDY
3.29
RETAINIED GBC TREES
FUTURE FOOTPATH RETAINING WALL DESIGN SURFACE EXISTING SURFACE RETAINING WALL
SECTION A
SCALE (A1):1:200 106
SCALE (A3):1:400
4.00 FUTURE CANTILEVERED SLAB OPEN
FIRE TRAIL RAC BUILDING PAD SPACE
RP BDY
RP BDY
FUTURE FUTURE RETAINING WALL
FOOTPATH
2.85 RAC FFL 30.6
3.20
TEMPORARY 1 in 3 BATTER
1 in 3 BATTER
RETAINING WALL DESIGN SURFACE EXISTING SURFACE RETAINING WALL
SECTION B
SCALE (A1):1:200 106
SCALE (A3):1:400
GRASSTREE COURT ENTRANCE RAC BUILDING PAD OPEN SPACE RAC BUILDING PAD OPEN SPACE
RP BDY
RP BDY
RAC FFL 30.6 RAC FFL 30.6
1 in 3 BATTER
RETAINING WALL DESIGN SURFACE EXISTING SURFACE FUTURE CANTILEVERED SLAB RETAINIED GBC TREES
SECTION C
SCALE (A1):1:200 106
SCALE (A3):1:400
RP BDY
INFILTRATION BASIN
RP BDY
FUTURE BIO
RETAINING WALL BASIN
RP BDY
RAC FFL 30.60
RAC FFL 30.60
TW=31.215 RL 27.40 RL 26.20 TEMPORARY
BW=30.471 TEMPORARY 1 in 3 BATTER
1 in 3 BATTER
EXISTING SURFACE PROPOSED SURFACE FUTURE FUTURE
EXISTING SURFACE DESIGN SURFACE FUTURE FUTURE CANTILEVERED SLAB RETAINING WALL
SECTION D CANTILEVERED SLAB RETAINING WALL
SCALE (A1): 1:200 106
SCALE (A3): 1:400
SECTION E SECTION F
SCALE (A1):1:200 106 SCALE (A1): 1:200 106
SCALE (A3):1:400 SCALE (A3): 1:400
TREE TO BE RETAINED
RETAINING WALL
RP BDY
DESIGN SURFACE EXISTING SURFACE
TW=31.986
BW=30.501
SECTION G
REFER 18-001942-108 FOR RETAINING
SCALE (A1): 1:200 106
SCALE (A3): 1:400 WALL SETOUT AND DETAILS
FILE: 5001-106-107.dwg DATE: 29-11-2018 USER: SHAUN PILCHER
XREFS: X-18-001942-SURVEY, X-18-001942-TITLE, X-18-001942-5001-BASE, X-18-001942-5001-CUT_FILL, X-18-001942-5002-CONTS
DESIGN DRAWN CHECK APPROVED DATE STATUS SCALE CLIENT PROJECT DRAWING TITLE
FIRST AMENDMENT DETAILS Calibre Professional Services (QLD) Pty Ltd
ISSUE CB CB - - 26.10.18
TENDER Level 3, 16 Innovation Parkway BLUE CARE SUNRISE BEACH EARTHWORKS
A CB CB SP SP 02.08.19 FIRE TRAIL AMENDED Birtinya QLD Australia 4575
A
M B CR NV SP SP 08.04.20 BASIN AMENDMENTS NOT FOR CONSTRUCTION
0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0
Telephone 07 5314 2520
Facsimile 07 5314 2522
RETIREMENT LIVING & SECTIONS
E
C CR CR SP SP 30.07.20 ISSUED FOR TENDER
N
D
M
D
APPROVED
SCALE 1:200 (A1) SCALE 1:400 (A3) AGED CARE
E
BY: SHAUN PILCHER RPEQ 14593 DISCLAIMER
PROJECT No. DRAWING No. REVISION
E
N ALL DIMENSIONS TO BE CHECKED ON SITE BY CONTRACTOR
F
T
S
G SIGN: DATE: 30.07.20
C calibregroup.com PRIOR TO CONSTRUCTION. USE WRITTEN DIMENSIONS ONLY,
DO NOT SCALE.
18-001942 5001-107 C
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - Attachment D - Amended Engineering Drawings.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.