“EC OF 9 “92
4400-02-CE
TGM REF. No.
DRAWING INDEX
BUNNINGS WAREHOUSE
EUMUNDI-NOOSA ROAD, NOOSAVILLE
ROUNDABOUT AND ROAD WORKS
GENERAL NOTES
THESE DRAWINGS SHALL BE READ IN
CONJUNCTION WITH THE SPECIFICATION AND
ALL OTHER RELEVANT CONSULTANTS
DRAWINGS, SPECIFICATIONS, CLIENT
INSTRUCTIONS, AND ANY WRITTEN
INSTRUCTIONS ISSUED DURING THE COURSE OF
THE CONTRACT. ANY DISCREPANCIES SHALL BE
REFERRED TO THE ENGINEER FOR DISCUSSION
BEFORE PROCEEDING WITH WORK.
DIMENSIONS SHALL NOT BE OBTAINED BY
SCALING THE DRAWINGS.
SUBSTITUTES WILL NOT BE PERMITTED
WITHOUT THE WRITTEN APPROVAL OF THE
ENGINEER.
DURING CONSTRUCTION THE SITE SHALL BE
MAINTAINED IN A STABLE CONDITION AND NO
PART OF THE SITE SHALL BE UNSAFE AS ‘A
RESULT OF THE CONSTRUCTION PROCEDURE.
MATERIALS AND WORKMANSHIP SHALL BE IN
ACCORDANCE WITH THE SPECIFICATION AND
SUNSHINE COAST REGIONAL COUNCIL
STANDARDS, THE CURRENT
REVISION OF ALL RELEVANT SAA CODES, THE
REQUIREMENTS OF THE QUEENSLAND BUILDING
REGULATIONS, THE BUILDING CODE OF
AUSTRALIA AND THE RELEVANT AUTHORITIES.
UNLESS NOTED OTHERWISE ON A PARTICULAR
DRAWING THESE NOTES SHALL APPLY
THE LOCATION OF UNDERGROUND SERVICES
SHOWN ARE INDICATIVE ONLY. THE
CONTRACTOR IS RESPONSIBLE FOR
CONTACTING ALL AUTHORITIES TO
DETERMINE THE LOCATION OF UNDERGROUND
SERVICES PRIOR TO THE COMMENCEMENT OF
CONSTRUCTION WORK. ANY CLASH OF
WORKS WITH A SERVICE IS TO BE REPORTED
TO THE ENGINEER IMMEDIATELY. THE
CONTRACTOR SHALL ENSURE THAT ALL
SERVICES ARE FULLY PROTECTED DURING
CONSTRUCTION, ANY SERVICES DAMAGED
DURING CONSTRUCTION SHALL BE REPAIRED
AT THE CONTRACTORS EXPENSE.
THE TERM “ENGINEER” SHALL MEAN A
REGISTERED PROFESSIONAL
ENGINEER QUEENSLAND
CONCRETE NOTES
ALL CONCRETE AND CONCRETE PRACTICE SHALL BE GENERALLY
IN ACCORDANCE WITH AS 3600 CONCRETE STRUCTURES CODE.
ALL INSITU CONCRETE SHALL HAVE A CHARACTERISTIC
STRENGTH AT 28 DAYS (F’c) OF 25 MPa UNLESS NOTED
OTHERWISE.
CONCRETE ELEMENTS SHOWN ON THESE DRAWINGS MUST NOT
BE REDUCED IN ANY WAY WITHOUT THE ENGINEER’S
APPROVAL. NO HOLES, CHASES, OR EMBEDMENTS, OTHER
THAN THOSE SHOWN WILL BE PERMITTED IN ANY CONCRETE
ELEMENTS WITHOUT THE ENGINEER’S APPROVAL.
REINFORCEMENT NOTATION
R - DENOTES STRUCTURAL GRADE PLAIN ROUND
BARS TO AS 1302
N - DENOTES HOT ROLLED DEFORMED BARS TO
AS 1302 (410Y)
SL72 - DENOTES REINFORCEMENT FABRIC TO AS 1304
(12 DENOTES SIZE OF FABRIC)
LAPPING REINFORCEMENT 5 50
MESH = = ° “= = a
TRENCH MESH 500mm FULL WIDTH AT INTERSECTION
BAR SIZE TOP BARS OTHER BARS
(300mm OR MORE
CONCRETE BELOW}
Ni2 300
N16 700 400
N20 600
COVER
CLEAR COVER TO REINFORCEMENT SHALL BE AS NOTED
ON THE DRAWINGS.
CONCRETE COVER SHALL BE MAINTAINED BY THE USE
OF APPROVED CHAIRS AND/OR CONCRETE BLOCKS.
CONDUITS, PIPES ETC. ARE NOT T0.BE PLACED IN
CONCRETE COVER.
THE SLUMP OF ALL CONCRETE AT THE TIME OF PLACING AT
THE JOB SHALL BE 75mm +/- 15mm TOLERANCE U.N.O.
ALL CONCRETE PLACED IN POSITION SHALL BE ADEQUATELY
VIBRATED.
ALL CONCRETE SHALL BE CURED TO THE APPROVAL OF
THE ENGINEER.
ALL PIPEWORK CAST INTO CONCRETE IS TO BE SLEEVED
OR LAGGED WITH APPROPRIATE COMPRESSIBLE
MATERIAL FOR THE FULL LENGTH OF EMBEDMENT.
CIVIL NOTES
ALL DIMENSIONS ARE IN MILLIMETRES UNLESS SHOWN
OTHERWISE. ALL LEVELS SHOWN ARE TO AUSTRALIAN HEIGHT
DATUM (TBM) AS NOTED ON THE PLANS. ALL SET-OUT
CO-ORDINATES ARE BASED ON AN ARBITRARY CO-ORDINATE
SYSTEM AS NOTED.
UNLESS OTHERWISE SPECIFIED OR APPROVED BY THE ENGINEER,
LAYING OF ALL PIPES OR CULVERTS SHALL COMMENCE AT THE
DOWNSTREAM END.
PRIOR TO ANY WORKS COMMENCING THE CONTRACTOR SHALL
COMPLETE A CHECK OF ANY EXISTING CONNECTING STORMWATER
DETAILS, INCLUDING INVERTS, DIAMETERS, DEPTHS, MATERIAL
ETC, TO CONFIRM ANY EXISTING DETAILS SHOWN ON THE
DRAWINGS. ANY DISCREPANCY SHALL BE REPORTED TO THE
ENGINEER.
STORMWATER DRAINS ARE TO BE PVC SEWER QUALITY PIPES
OR REINFORCED CONCRETE AS NOTED.
RC PIPES ARE TO BE RUBBER RING JOINT.ED CLASS 3 UNDER
VEHICLE PAVEMENTS. ALL RC PIPES ELSEWHERE ARE TO BE
CLASS 2 WITHOUT RUBBER RING JOINTS.
DRAINAGE PIPES MUST BE BEDDED IN ACCORDANCE WITH THESE
DRAWINGS.
DRAINAGE, SERVICES AND CONDUIT TRENCHES UNDER
PAVEMENTS, FOOTPATHS AND PAVING ARE TO BE BACKFILLED
TO THE UNDERSIDE OF THE PAVEMENT WITH AN APPROVED
CONSOLIDATED MATERIAL IN ACCORDANCE WITH THE RELEVANT
MUNICIPALITIES CONDITIONS. :
THE LOCATION OF EXISTING UNDERGROUND SERVICES SHOWN IS
INDICATIVE ONLY. THE CONTRACTOR IS RESPONSIBLE FOR
CONTACTING ALL AUTHORITIES TO DETERMINE THE LOCATIONS
OF UNDERGROUND SERVICES AND OTHER ASSOCIATED WORKS,
ANY CLASH OF THE WORKS WITH A SERVICE IS TO BE REPORTED
TO THE ENGINEER IMMEDIATELY. THE CONTRACTOR SHALL
ENSURE THAT SERVICES ARE FULLY PROTECTED DURING
CONSTRUCTION. ANY SERVICES DAMAGED DURING CONSTRUCTION
SHALL BE REPAIRED AT THE CONTRACTORS EXPENSE.
SERVICES OTHER THAN THOSE SHOWN ON THE DRAWINGS MAY
EXIST. THE CONTRACTOR IS TO ALLOW FOR THE ALTERATION TO
SERVICES WITHIN THE SITE, INCLUDING THE ADJUSTMENT OF PIT
COVER LEVELS AND. THE REMOVAL AND SEALING OF UNWANTED
SERVICES & ASSOCIATED PITS & FITTINGS.
EXPOSED SUBGRADE AREAS SHALL BE PROOF ROLLED UNDER
THE SUPERVISION OF THE ENGINEER USING A 10 TONNE AXLE
LOAD, SOFT AREAS DETECTED SHALL BE EXCAVATED AND
BACKFILLED AS DIRECTED BY THE ENGINEER.
THE PAVEMENT SUB-BASE COURSE IS TO BE COMPACTED TO
97% MODIFIED MAXIMUM DRY DENSITY COMPACTION. THE
PAVEMENT BASE COURSE TO 98% MODIFIED MAXIMUM DRY
DENSITY.
ALL WORKS ADJACENT TO THE SITE ARE TO BE APPROVED
INSPECTED BY SUNSHINE COAST REGIONAL COUNCIL.
THE ORIENTATION OF ALL STORMWATER DRAINAGE ACCESS
COVERS & GRATES ARE SHOWN INDICATIVELY AND ARE TO BE
MANUFACTURED & INSTALLED IN ACCORDANCE WITH
AS3996-2006.
COUNCIL HOLD POINTS
IN ACCORDANCE WITH HOLD POINTS SPECIFIED IN PRE-START
DOCUMENTATION. ALL HOLD POINTS TO BE CERTIFIED BY A RPEQ
ENGINEER.
PROVIDE TOOLED JOINTS IN KERBS, KERB AND CHANNEL AT 2.0m
MAXIMUM CENTRES.
SAWCUT EXISTING KERBS & PAVEMENTS WHERE REQUIRED FOR
INSTALLATION OF NEW KERBS AND WHERE NEW WORK IS TO
MATCH EXISTING.
THE CONTRACTOR SHALL AT ALL TIMES DURING THE CURRENCY
OF THE WORK PROTECT THE PUBLIC FROM THE WORKS, PLANT,
TRENCHES ETC. OCCASIONED BY THE WORKS BY THE USE OF
APPROVED BARRICADES AND BARRIERS. SUCH PROTECTIVE
MEASURES WILL BE SUBJECT TO THE APPROVAL OF THE
ENGINEER AND A REPRESENTATIVE FROM SUNSHINE COAST
REGIONAL COUNCIL. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR ANY DAMAGE OR INJURY ARISING FROM THE NEGLECT OR
INSUFFICIENCY OF SUCH PRECAUTIONS.
THE CONTRACTOR IS ADVISED THAT THE MINES (TRENCHES)
REGULATIONS 1982 WILL APPLY TO THIS PROJECT. THE
CONTRACTOR IS REQUIRED TO SATISFY AND/OR PUT INTO
EFFECT ALL REQUIREMENTS. OF THOSE REGULATIONS AND THOSE
OF THE OFFICE OF MINERALS AND ENERGY.
THE WORKS SHOWN HEREIN ARE SUBJECT To THE SUPERVISION
OF THE PRINCIPAL’S APPOINTED SUPERINTENDENT.
CARE IS TO BE TAKEN TO PROTECT EXISTING FENCES, BUILDINGS,
FITTINGS, SERVICES, FURNITURE, SIGNAGE, TREES AND OTHER
ITEMS TO BE RETAINED FROM ANY DAMAGE.
UNWANTED PITS, PIPES SERVICES ECT. IN PAVEMENT AREAS ARE
TO BE REMOVED AND THE HOLE BACKFILLED WITH AN APPROVED
CONSOLIDATED MATERIAL IN ACCORDANCE WITH THE RELEVANT
MUNICIPALITIES CONDITIONS.
THE CONTRACTOR SHALL INSPECT THE SITE AND DETERMINE THE
EXISTING ASPHALT PAVING, PITS, PIPES, SERVICES, TREES,
KERBS, DRAINS, BUILDINGS, FITTINGS, FURNITURE, SIGNAGE, ETC.
THAT ARE TO BE REMOVED AND HE SHALL ALLOW IN HIS TENDER
PRICE FOR ALL COSTS ASSOCIATED WITH THE NECESSARY
REMOVAL.
IN AREAS WHERE THERE IS TO BE FILLING UNDER PAVEMENT
AREAS, THE SUBGRADE SHALL BE CLEARED OF ANY ROOT
MATTER AND LOOSE MATERIAL TO THE DESIGN LEVELS. THE
SUBGRADE AREA SHALL BE PROOF ROLLED UNDER THE
ENGINEERS SUPIVISION USING A 10 TONNE AXLE LOAD TO
LOCATE ANY SOFT SPOTS. ANY SOFT SPOTS SHALL BE
EXCAVATED AND REPLACED WITH AN APPROVED MATERIAL IN
150mm COMPACTED LAYERS TO A MODIFIED DRY DENSITY OF 95%
COMPACTION.
THE CONTRACTOR SHALL ALLOW TO PROVIDE TEMPORARY
SHUTTERS FOR ALL TRENCHES AS NECESSARY.
SURPLUS SPOIL NOT REQUIRED BY THE DEVELOPER SHALL
BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE
REMOVED FROM THE SITE, TC THE MUNICIPAL TIP OR A SITE
APPROVED UNDER THE COUNCIL PLANNING & ENVIRONMENT ACT
AND THE EPA ACT.
THE CONTRACTOR SHALL DEVELOP AND ENSURE THE STRICT
IMPLEMENTATION OF AN APPROVED SITE ENVIRONMENT
MANAGEMENT SYSTEM GENERALLY IN ACCORDANCE WITH THE
RELEVANT EPA QUEENSLAND REGULATIONS.
FOR APPROVAL
EC10F 9 | GENERAL NOTES & DRAWING INDEX
EC2 OF 9 | PROPOSED ROUNDABOUT PAVEMENT LAYOUT PLAN
EC3 OF 9 | GATEWAY DRIVE CROSS SECTIONS
ECh OF 9 | EUMUNDI EAST CROSS SECTIONS
ECS OF 9 | EUMUNDI WEST CROSS SECTIONS
ECé OF 9 | KERB SETOUT CO-ORDINATES AND LEVELS
EC7 OF 9 | GATEWAY DRIVE LONGITUDINAL SECTION
EC8 OF 9 | DRAINAGE LONGITUDINAL SECTIONS
EC9OF9 | LINEMARKING PLAN
= maa een
02
ISSUED FOR APPROVAL
24/06/11} SM.
SURVEY:
SHEET SIZE: y4
CHECKED:
APPROVED:
DATE:
DATE:
©) COPYRIGHT T.G.M GROUP PTY, LTD.
& —— J
TG
TGM GROUP Pty Ltd BSlax
Ballarat @
1315 Sturt Street ©
Ballarat, VIC 3350
Ph: (03) 5330 8888 ——auawiso. 00!
Web: tgmgroup.com —_—ougs ASINZS 4804
A.B.N. 11.125 568 461 — emironmexASINZS 14004
CLIENT:
H. TROON PTY. LTD.
ALUMINIUM AND STEEL FABRICATORS
BUILDERS - COMMERCIAL AND INDUSTRIAL
P.O. BOX 84, WENDOUREE, 3355.
Tel: {03} $339 2208 ~ (03) 5339 3622
Fax: (03) 5338 1310
Email: [email protected]
PROJECT:
PROPOSED BUNNINGS
WAREHOUSE
EUMUNDI-NOOSA ROAD
NOOSAVILLE, QUEENSLAND
CIVIL DRAWING
DRAWING TITLE:
GENERAL NOTES & DRAWING INDEX
TGM REF. No.: SHEET:
4400-02-CE
ECi'9
REV:
02
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Amended Plans for approval - Bunnings WarehouseRelated documentApplication case desk ↗
About this file
- File size
- 57.8 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.