Council archive · source document
Request for Further Information - 010.2008.00000201.001 [As Published] · 132008.201
-2-
4. Under the Superseded Schedule to the Planning Scheme a basement floor level shall
be a minimum of 1.2m under Natural and Finished Ground Levels. As such, the
natural ground level is required to be reinstated around the basement area and deep
planting provided as screening. A copy of explanatory sketches is attached for your
reference.
The proposal plans include an entrance staircase and swimming pool (which extends
approx. 1.5 above ground and is within the front setback area) in front of the
basement parking level. The proposal is therefore considered to constitute a 3-storey
building. Please provide amended plans to relocate these structures and provide
deep landscape areas along the frontage of the basement level.
5. The Plot Ratio for the proposal has been calculated as 50.1%. Please provide
amended plans to comply with the maximum GFA provisions of the Superseded
Schedule to the Planning Scheme.
6. Please amend the location of the front fence to provide for a minimum 1m width of
screening vegetation to be established between the front boundary and any fencing.
Land Development
7. Please amend the plans to indicate the proposed levels of the buildings related to
Australian Height Datum (AHD).
8. Please provide a longitudinal section of the centreline of the access driveway
extending from the existing kerb and channel to the entrance of the basement. The
design of the driveway shall be in accordance with AS/NZS 2890.1:2004, Council’s
Planning Scheme Policy 5 – Engineering Design Standards – Roads, Drainage and
Earthworks and IPWEAQ drawing R-0050. The design shall maintain the levels at the
property boundary, include a 1.5m wide footpath section with a maximum crossfall of
2.5% and at levels to ensure that the driveway is free draining to the front boundary.
9. Please demonstrate how vehicles can access each carspace in a forward gear,
reverse out and exit the site in a forward gear in a total of 3 movements. The vehicle
manoeuvring for each space shall be provided clear of any other carspace. The
manoeuvring area and the vehicles shall be in accordance with AS/NZS 2890.1:2004
for user class 1A.
10. Please provide a preliminary stormwater disposal design for the development. The
design shall include pits, pipes, driveway grates and runoff collection and reuse tanks.
The location of the reuse tanks shall be clearly shown on the plans and the capacity
of the tanks shall be in accordance with The Noosa Plan and the Queensland
Development Code.
11. Please provide a site investigation prepared by a Geotechnical Engineer or similar
qualified expert that determines the soil classification and establishes whether any
measures are required to protect the stability of adjoining buildings and/or structures
and/or lands. The report shall make recommendations on the type of foundation
system(s) best suited for the proposed development and identify if any specific
methods for retention works during the excavation and construction stages are
required.
Under the provisions of the Integrated Planning Act 1997, you have three options available
in response to this Information Request. You may give the assessment manager (in this
instance Council) and each referral agency (if any):
1. all of the information requested; or
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Request for Further Information - 010.2008.00000201.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 13 KB (small file)
- File type
No other editions are linked here.