Original source · versioned page text
Approved Plans OPW25-0057
Plans and drawings: the text below has words only, no drawings.
Very large file (20.9 MB): may take a few minutes to open.
Original PDF page 20, section 1. The text section number identifies this passage in the reader.
IT IS THE RESPONSIBILITY OF THE
102
104
CONTRACTOR TO CONTACT THE RELEVANT
102
106
AUTHORITIES TO CONFIRM THE LOCATION OF
ALL EXISTING SERVICES PRIOR TO THE
COMMENCEMENT OF EXCAVATION
102
-
WILGEE CT
APPROVED PLAN
101
OPW25/0057
EXISTING
STREET LIGHT NOOSA COUNCIL
10
1
20 AUG 2025
102
1 03
8
5
10
X1 3
3 10
X6
103 PROPOSED GREEN
CYCLE LANE
TREATMENT ACROSS 103
INTERSECTION 104
CH 236.984
CH 199.742
CH 249.239
CH 210.413
CH 224.448
CH 192.070
CH 240
CH 280
CH 200
CH 270
CH 260
CH 230
CH 250
CH 210
CH 220
10
4
REFER EXTERNAL ROADWORKS DETAIL - SHEET 1 FOR CONTINUATION
3
10
105
LAKE MACDONALD DR
3m
CL CL CL
D EXISTING ROAD NAME AND "NO
THROUGH ROAD" DUAL BLADE
SIGN TO BE RELOCATED
3m
BEHIND NEW KERB
34 27 LEGEND
28
2m
33 103 7
X1 26
32 29 10
1m
PROPOSED LINEMARKING
104
6
103 C
M1 K& PROPOSED RRPM's IN EXISTING LINEMARKING TO REMAIN
2.5m
ACCORDANCE WITH
M1 31 30
R8
AS1742.2-2009 105 PROPOSED SAWCUT LINE
K& (MUTCD) SECTION 5.6
m(
C JOIN TO PROPOSED SUBSOIL DRAINAGE
INV
EXISTING KERB 104 EDGE OF BITUMEN
)
M1
C
JOIN TO
K&
R8m (INV) EXISTING R2-1 "GIVE JOIN TO
K&
REPLACE EXISTING PATH WITH NEW 2.5m YELLOW BIDIRECTIONAL RRPM
M1
EXISTING KERB EXISTING 2m
C
LA CT
WAY" SIGN TO REMAIN WIDE CONCRETE FOOTPATH GENERALLY IN 104
1 103 WIDE PATH YELLOW UNIDIRECTIONAL RRPM 105
4 ACCORDANCE WITH IPWEA STD DRG RS-065
EXISTING X2 X3
102 AND NSC ADDENDUMS PROPOSED ROAD PAVEMENT
ELECTRICAL 103
DIANEL
W6-1 + W8-25
PILLAR PEDESTRIAN
EXISTING 2.5
m CROSSING SIGNAGE PROPOSED ROAD WIDENING
STREET LIGHT 101
103
102
102 PROPOSED CONCRETE FOOTPATH
JOIN TO
103
EXISTING PATH
EXISTING PROPOSED CONCRETE DRIVEWAY
EXISTING STREET LIGHT SUBSOIL DRAIN
ELECTRICAL CONNECTION TO
TRANSFORMER EXISTING STW PIT BIORETENTION BASIN FILTER SURFACE
103
LAND RESUMPTION
2.5m
103
3 PROPOSED STORMWATER DRAINAGE
X2
REPLACE EXISTING PATH WITH NEW 2.5m
103
PROPOSED Ø150 PVC-O PN16 WATER MAIN
103
WIDE CONCRETE FOOTPATH GENERALLY IN
ACCORDANCE WITH IPWEA STD DRG RS-065 PROPOSED Ø150 UPVC SEWER MAIN
103
AND NSC ADDENDUMS
EXISTING UNDERGROUND STORMWATER DRAINAGE
103
102
102
EXISTING WATER MAIN
EXISTING COMMUNICATIONS CABLES
ENERGY SERVICE PROVIDERS TELECOMMUNICATIONS
KERB RETURN SETOUT AGL SERVICE PROVIDERS elstra EXISTING UNDERGROUND ELECTRICAL
ERGON. AUSTRALIA
POINT EASTING NORTHING LEVEL POINT EASTING NORTHING LEVEL ENERGY
energex Telstra visionstream EXISTING OVERHEAD ELECTRICAL
origin
NOTE: SERVICE LOCATIONS ARE APPROXIMATE ONLY FROM
OPTUS
NOTE: SERVICE LOCATIONS ARE APPROXIMATE ONLY FROM
WARNING: OPTIC FIBRE EXISTING SITE BOUNDARY
PROVIDERS PLANS. LOCATIONS ARE TO BE CONFIRMED PROVIDERS PLANS. LOCATIONS ARE TO BE CONFIRMED
EXTREME CARE TO BE TAKEN WHILE EXCAVATING IN THE
PRIOR TO START OF CONSTRUCTION. PHONE DBYD PRIOR TO START OF CONSTRUCTION. PHONE DBYD VICINITY OF OPTIC FIBRE CABLES. LOCATIONS ARE TO 10 DESIGN SURFACE CONTOURS (250mm INTERVALS)
SERVICE LOCATIONS ON 1100 FOR DETAILS. SERVICE LOCATIONS ON 1100 FOR DETAILS. BE CONFIRMED PRIOR TO START OF CONSTRUCTION.
10 EXISTING SURFACE CONTOURS (250mm INTERVALS)
Check all dimensions before commencement of work.
NOTE: Check Site boundary dimensions from the Title plans
ALL LINE MARKING AND DELINEATION TO BE IN Check Building Boundary clearances by set out.
Notwithstanding the information supplied on this drawing,
ACCORDANCE WITH THE MANUAL OF UNIFORM the location, depth and extent of underground or overhead
SCALE 1:125 (A1) - 1:250 (A3)
TRAFFIC CONTROL DEVICES (MUTCD) services are to be confirmed and protected on site by the
contractor prior to commencement of works.
Approved
Checked - CT Drawing title - Project - PROPOSED 1 INTO 3 Site - Project No. 233467 Sheet No. C251
Design - SK Drawn - SK D 24/03/2025 UPDATED PROJECT NAME SK EXTERNAL ROADWORKS DETAIL - DEVELOPMENT 62 LAKE MACDONALD DRIVE, Digital Ref :
C250-C251 EXTERNAL
ROADWORKS DETAILS Issue : D
C 14/03/2025 UPDATED LOT LAYOUT SK
Scales - AS SHOWN B 20/09/2024 ISSUE FOR APPROVAL SK COVEY ASSOCIATES PTY LTD 124 DUPORTH AVENUE SHEET 2 Client -
NOOSA COUNCIL COOROY This Document is copyright and shall not be copied
A 10/01/24 ISSUE FOR CLIENT REVIEW SK
ABN 59 137 305 992 PO BOX 16 without written approval, nor shall it be used except
Document Stage - APPROVAL (07) 5443 7777 MAROOCHYDORE QLD 4558 for the Development and the Site Specified.
Issue Date Description By [email protected]
c:\12dS\data\12DSERVER\233467_2957\DWG Covey\OPW\Uncontrolled\C250-C251 EXTERNAL ROADWORKS DETAILS.dwg Plot 4 July 2025 - 5:07 PM
Document Set ID: 23931062
Version: 1, Version Date: 15/07/2025
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.