105
10
3 1
2
28m2 Groundcovers - Streetscape Areas 1 2
- Even mix of 1 plant per 1m2
- refer to plant schedule for species 3 5
103
3 ACR imp 3 ACR imp
ax 6
22m2 Groundcovers - Streetscape Areas 3m
- Even mix of 1 plant per 1m2 1 in 1 75mm tubestock as per planting plan. Planting hole
4 two times wider than plant pot size. Topsoil as per
- refer to plant schedule for species
1 MEL aze 5 specification, with water crystal additive.
5 MEL aze
REFER TO SHEET 3 2 Coir net pinned with 300mm length pins as per
Manufacturer's specification over 100mm depth
L200 mulch as specified.
Contact Geofabrics (ph 07 3279 1588)
PA 6 3 Slow release fertilizer as per Manufacturer's
recommendations. Choose appropriate fertiliser for
PA A species selection. 1 75mm tubestock as per planting plan.
Bio Basin maintenance
104
ARV 1 TRI LU
access. Gate or removable
4 100mm deep topsoil as per specification spread Planting hole two times wider than plant pot size.
PA
ARV
FA
LL
103 bollards to Noosa Council
specifications.
6 MYO par 7
5
6
7
across planting area.
300mm length pins.
Ripped and 'stepped' subgrade to 150mm depth.
Subgrade.
2
3
5
6
75mm depth commercial grade straw mulch covered with coir net
pinned with galvanised pins as per Manufacturer's specification.
Slow release fertilizer as per Manufacturer's recommendations.
Choose appropriate fertilser for species selection.
Galvanised pins installed as per Manufacturer's specification.
Filter media as per Engineer's specification.
ARV
-
APPROVED PLAN
3 BAC myr
OPW25/0057
TYPICAL BATTER PLANTING TYPICAL BIOBASIN PLANTING
ARV SCALE 1:10
NOOSA COUNCIL SCALE 1:10
20 AUG 2025
290
Sign Type 1 Notes:
To be SCC Custom 'Education Sign' plate stand type.
Sign panel to be 290wx210hx3mm thick 316 aluminium plate
Finish to be powder coated Dulux (or approved equivalent) colour: 'Monument Satin'
This bioretention basin has been designed and installed to Sign panel artwork to be vinyl wrapped and laminated.
retain and remove pollutants from stormwater runoff. Native Sign post to be 75x75mm HWD post installed 400mm above ground line
5
plants and the installed sub-grade filter the water as it passes
Final design and material to be approved by Council.
3
through the system. Bioretention basins help protect our
0
10
creeks from the impact of urban stormwater run-off.
1:4
r 2 MEL aze
tte
ba
ba L
1
210
F
1:4
0
L 200m2 Bio Basin Batters
A
L ARV
tt
FA
L
Amenity Reveg Area
er
- Even mix of 2 plant per 1m2 Bio-basin Planting Rationale
ARV - Refer to plant schedule for species
1
Bio basin Floor Planting Biobasin filters primary function is for water quality treatment. It is an area
Area = 186m² which will be periodically inundated with water and permanently or periodically
Install plants at 6/m² support the growth of the macrophyte species. It should be designed, operated
BAU rub - 10% and maintained as a sustainable facility to provide the desired level of
FIC nod - 10% stormwater treatment. Correct design, construction and maintenance of the
JUN usi - 10% facility will ensure that discharges are of such quality that environmental values
6
LOM hys - 35% of downstream receiving waters are protected or enhanced.
LOM mul - 35% This bioretention basin has been designed and installed to retain and remove pollutants from stormwater runoff. Native plants and the installed
QCGC
sub-grade filter the water as it passes through the system. Bioretention basins help protect our creeks from the impact of urban stormwater run-off.
Install straw mulch and jute mesh in
SIGN TYPE 1 - BIOBASIN EDUCATIONAL SIGNAGE
10
accordance with WSUD requirements
Refer to Schedule for quantities SCALE 1:5
103
104
3 SYN gla
Macrophyte planting with straw mulch
Refer to Engineer's documentation for all and jute mesh cover to basin floor
biobasin and batter specifications and details - refer to below schedule for species,
densities and quantities
Revegetation planting with mulch and jute netting cover to batters - jute mesh to be pinned and installed
- refer to adjacent schedule for species, densities and quantities as
- jute netting to be pinned and installed as per Manufacturer's per Manufacturer's specifications
specifications
Nom.0.5m wide maintenance
access clear of planting to top of
bund
Biobasin batter profile
to Engineer's
INDICATIVE SECTION A-A specifications
- refer to Engineer's
Biobasin filter media and drainage layers documentation
- refer to Engineer's documentation for details and
SCALE 1:50 (A1) specifications
0 1 2 3 4 5 (A1) 1:100 10
Metres
(A3) 1:200
Approved by: James Oliver (AILA)
Checked - JO F 03.07.2025 MCU RFI AMENDMENTS JO
Drawing title - Project - Site - Project No. 233467 Sheet No. L500
Design - JO Drawn - JO
E 17.04.2025 SPECIES CHANGE JO
LANDSCAPE PLANS Proposed 1 into 3 Development 62 Lake MacDonald Drive, Cooroy
D 24/03/2025 UPDATED PROJECT NAME AR Digital Ref : 233467 L100 Landscape Plans Issue : F
C 12.03.2025 FOR APPROVAL JO BIO BASIN
Scales - AS SHOWN B 24.09.2024 FOR APPROVAL IL 124 DUPORTH AVENUE Ph (07) 5443 7777 Client - This Document is copyright and shall not be copied
PO BOX 16 Fax (07) 5443 7577 without written approval, nor shall it be used except
Document Stage - FOR APPROVAL
A 31.05.2024 PRELIMINARY - FOR COORDINATION ONLY JO
MAROOCHYDORE QLD 4558 Noosa Council for the Development and the Site Specified.
Issue Date Description By E-MAIL: [email protected]
c:\12dS\data\12DSERVER\233467_2957\DWG Covey\Landscape\Uncontrolled\233467 L100 Landscape Plans.dwg
Document Set ID: 23931061
Version: 1, Version Date: 15/07/2025
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.