4.8 Erosion Control & Landscaping
Performance Criteria: -
@ Control erosion as this may lead to instability.
«@ Revegetate cleared area.
Acceptable measures: -
Prior to construction, an erosion and sediment control plan should be established. This document can be
referenced to the publication, “Soil Erosion and Sediment Control” - The Institution of Engineers Australia.

49 Construction Recommendations
Performance criteria: -
HOUSE DESIGN:
¢ Use flexible structures, which incorporate properly, designed brickwork, timber or steel
frames, timber or panel cladding.
¢ Consider use of split-levels.
¢ Use decks for recreational areas where appropriate,
Acceptable measures: -
The residential area will be benched into the crown and near flank,

4.10 Site Maintenance

Long-term stability of the house foundations is the Tesponsibility of the owner/occupier of the
dwelling. Large changes in moisture conditions around the structure's footings (inconsistent watering
patterns), will cause movement, and may lead to damage of the house. Further, trees are to be planted
away from the structure area in order not to adversely affect the foundation performance, You are
advised to read the report, “Foundation Maintenance and Footing Performance: A Homeowner's
Guide", sheet No. 10-91, produced by Dr P.F. Walsh of the CSIRO, which can be downloaded from
http://www.publish,csiro.au/nid/22/pid/3612.htm.

5. CONCLUSION

5.1 ) Surrounding two and single storey residences are located on similar topographic and geological

units

 
 
 

5) We conclude the crown and near flank area as described will have a negligible landslip impact
risk with no significant geotechnical development constraints however building structures and filling is
excluded on slopes that exceed 1:3 (V:H).

i ) Residential development and effluent-disposal on this site should consider:
¢ Foundation site classificatidn “H” (AS2870):
Residential founding to a onion 1.2 metres below the existing ground level;
Building platform is prepared as a “controlled” fill;
Fill batters no steeper than 1:2 (V:H):
On-site effluent disposal southeast of the residence and to incorporate low volume output

e¢ ¢ + @

application methods.

 

Office at: 1/8 Denna St, Maroochydore, Q, 4558,
Phone: 5443 6622, Fax: 5479 1899, Email: [email protected]
Log in to download the original file

Information response - GEOTECH REPORT.pdf · 952 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.