A B C D E
ST
6840 1980 7680 4000
1 existing dwelling
400.02
CP existing
stormwater
1 1 BUP 5815 1 1
400.05 400.03 400.04
ST
300.04
site boundary | 38.150 | 48° 23'
site b
0
.0
20
ound
ST
ST
ST ST
ST ST
ST
easement
ary |
natural ground
.081 7
| 303
2x mdp01 bbq01 2.5m side setback
1
° 41 '
Pool Deck
40"
mdp01 RL 18.770
Shr up
up pool deck less than 1m above
step 4 3 2 1 natural ground level
til01
2660
Lobby seat
Cellar RL 19.510
til01 con01 inground pool not considered a
RL 19.510 structure according to code
Powder
2 FFL 18.770
con01 seat
1980
Lift Outdoor Room
1 RL 18.770
400.01 tim02
4
3
line of building over
3
2x mdp01 2 1
300.03
1
up
Gym natural ground Pool
r
RL 18.670
ov e
RL 19.510
y
con01
tore
1 1 Pool House
5440
rd s
400.00 050.02 RL 18.070
RL 18.770
of 3
con01
l in e
1 seat
300.00
site boundary
hwu01 hwu01 Store seat 3
2
1
4 mdp01 sliding gates up 2.5m side setback
shr
| 8.268 | 313°
up up RL 17.570 up
5 4 3 2 1 10 9 8 7 6 5 4 3 2 1
9.0m rear setback
4 3 2 1
line of stairs above
0
17.00
natural ground
19.00
18.0
29' 30"
site boundary | 35.647 | 228° 23'
line of building over
red hatch area complies with "basement" area to the right of the red line constitutes
definition according to the code therefore 1 the first "level" as defined by the code. the
300.02
does not constitute as a level red line indicates the limit of the upper most
level & as below this zone is 3 levels
LOT 598
neighbouring duplex neighbouring duplex
entry stair below covered walkway below RP 48112
existing 3 storey
duplex dwelling
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV
PROJECT NO 0309
DL
DL
B
C
24.04.20
11.05.20
SD Issue
Prelim Council RFI
40 Park Crescent, Asha & Sandeep Floor plans SD 200.00 E SCALE 1 : 100
Sunshine Beach Biswas
A3
DL D 13.05.20 Council RFI Ground floor
DL E 08.06.20 Revised Council Submission schematic design
1:1 @
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - Attachment B - Stormwater management Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 7.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.