Original source · versioned page text
RFI - Attachment 7 - Updated SWMP
Table 3-6: Bioretention and Raingarden Design Parameters
Parameter Bioretention Basin (55m2) 2 × Rain Gardens (5m2)
Extended Detention Depth (m) 0.30 0.20
Storage Surface Area (m2) 55 10
Filter Media Area (m2) 55 10
0.01
Unlined Filter Media Perimeter (m) 0.01
Saturated Hydraulic Conductivity 200
200
(mm/hr)
Filter Depth (m) 0.50 0.50
400
TN Content of Filter Media (mg/kg) 400
Orthophosphate Content of Filter Media 30
30
(mg/kg)
Exfiltration Rate (mm/hr) 0.00 0.00
3.3. Results
MUSIC modelling of the proposed treatment train for the renovation work at Good Shepherd Lutheran
college was performed to ensure the WQO’s were achieved. Table 3-7 represents the load-based outputs
that are represented by this application. The results show the mitigated scenario, which achieves compliant
load reductions set out within Noosa Council’s 2020 Plan.
Table 3-7: MUSIC Results – Load Based Pollutant Outputs
Unmitigated Mitigated Reduction Target
Pollutant Compliance
(kg/yr) (kg/yr) Achieved (%) Reduction
TSS 2740 548 80 80% ✓
TP 5.56 1.45 73.9 60% ✓
TN 31.9 14.5 54.6 45% ✓
GP 231 0 100 90% ✓
21-0211SMP01V1 | Stormwater Management Plan | Good Shepherd Lutheran College Arts Centre Page 14