Slab Fabric
Block Retaining Wall Specifications
(200 Series Blockwork}
Min 1:20 Falt
—
55 Cover
1600 .
Max Reinforcement Bars as
per Table Below
Granular
Non-Compressible
Free - Draining
Back
Waterproofing
rE A.G.Drain
} to efficient
Oo he nutiow
Retaining Wall Specifications
Starter Bars at
400 1.0m Centres :
v <J-— 31127
ko
fe
Base Width
All bottom steel must have 40mm bottom cover.
Notes:
- Retaining wall footings to be founded to the
recommended founding material as per page
1 of the report.
- All excavations to be finished cleaned and
horizont:
- The retaining wall is not to be backfilled for
a minimum of 1 week after concrete core
- All cores to be infilled with concrete grout -
418MPa minimum.
- Concrete is to be vibrated / rodded into the
block cavity.
Wall Height Base Width Reinforcement
0 - 600 500 N12 Bars at 1.0m Centres
800 600
N12 Bars at 400 Centres
1000 700 Horizontal and Vertical
1200 900
1400 1100 N16 Bars at 400 Centres
4600 1200 Horizontal and Vertical
- Waterproofing to be placed as per the
manufacturers specifications
Note* Footing & Wall Cavity must be vibrated.
* Trench Mesh and Steel Reinforcement must have a minimum 500mm lap.
* All bottom steel must have 40mm bottom cover.
‘
'
Project Job No_ ES98868-B Amended 19/04/2010
Continuous Footin
Single Skin Block At Engaged Piers
if
Tt Reinforcement
iyo as per Structural Engaged Piers
Block Face ad . Design Plans
' ‘ Reinforcement
1 as per Structral
1 Design Plans
‘
‘
600 . . 600
Footing Reinforcement t
(tench mesh, 40mm cover)
Wow
Plan View
~ Widen Footing
under each Pier
Reinforcement
as per Structural
Design Plans.
Engaged Piers
Footing Reinforcement
(trench mesh, 40mm cover)
Footing Reinforcement
(trench mesh, 40mm bottom cover)
Block Face
Stepping Strip Footing
zx
Step > 200mm
but < 2D
¥
DB Footing Beam
Y~
| 150 fe
Steel Reinforcement Product Code Steel Strength
Continuous Footing Reinforcement 3L11 TM Cage 500 Grade
(Top and Bottom) Concrete Strength 20MPa
Notes:
* Continuous Footing must be vibrated.
* Trench Mesh and steel reinforcement must have a minimum 500mm lap.
* All bottom steel must have 40mm bottom cover, bar chairs are to be placed
at 800mm centres, R6 ligatures at 900mm centres.
F600
Design Company
STA CONSULTING ENGINEERS
Unit 6, 848 Boundary Rd, Richlands, Qld, 4077
ACN 129 441 890 Fax (07) 33759299 Ph.3363 8181
Client
Monte Constructions *
PO Box 8425, Woolloongabba Qld 4102
CONSULTING
ENGINEERS
Site Address
Lot 13, No.13 Grant Street, Noosa Heads
Page 4 of7
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
10/0662 - Operational Works [As Published]Related documentApplication case desk ↗
About this file
- File size
- 7.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.