GENERAL NOTES

REQUIREMENTS.
2. THESE DRAWINGS ARE DIAGRAMMATIC ONLY. USE DIMENSIONED BUILDING CONSTRUCTION PLANS FOR ANY
SET OUT REQUIREMENTS,
3, OBTAIN APPROVALS FROM ALL AUTHORITIES HAVING JURISDICTION AND PAY ALL FEES DUE,
4, THE CONTRACTOR IS TO VISIT THE SITE TO BE FULLY AWARE OF EXISTING SERVICES AND SITE CONDMIONS
PRIOR TO COMMENCEMENT OF WORK. ANY CLAIM FOR VARIATION ON THE BASIS OF LACK OF KNOWLEDGE
WILL NOT BE ACCEPTED.
5, _ ENSURE INVERT LEVELS AND MINIMUM COVER IS ACHIEVABLE PRIOR TO COMMENCEMENT OF WORK ON SITE.
6. _ALLPLUMBING AND DRAINAGE SERVICES THAT PENETRATE FIRE RATED WALLS AND FLOORS MUST BE
INSTALLED 70 COMPLY WITH THE REQUIRED FIRE RESISTANCE LEVEL.
SANITARY NOTES
1. ALLSANITARY AND TRADE WASTE PIPEWORK SHALL BE 100MIM@ AND BE INSTALLED AT 1:60 MINIMUM
GRADE (UNO).
2. PROVIDE INSPECTION OPENINGS ON SANITARY DRAINAGE IN COMPLIANCE WITH AS/NZS 3500.2
3. AN OVERFLOW RELIEF GULLY SHALL BE INSTALLED ON EACH DRAIN CONNECTION TO SEWER AND EACH DRAIN
ON AN UNSEWERED PROPERTY.
4, ANINSPECTION SHAFT TO BE INSTALLED AT OR NEAR THE POINT OF CONNECTION TO THE SEWER (UNO).
STORMWATER NOTES
1. ALLSTORMWATER DRAINAGE SHALL BE 100MIM@ AND BE INSTALLED AT 1:100 MINIMUM GRADE (UNO).
2. DOWNPIPES TO HAVE MINIMUM CROSS SECTIONAL AREA EQUAL TO 100MM (UNO).
3. ROOF GUTTERS AND DOWNPIPES 70 FULLY COMPLY WITH THE REQUIREMENTS OF AS/NZS3500:3. ABBREVIATIONS
MATERIALS AAV AIR ADMITTANCE VALVE
1, WATER SERVICES -TO AS/NZS 3500 B BASIN
2. SANITARY DRAINAGE - PVC CLASS DW cw COLD WATER
3, SANITARY PLUMBING - PVC CLASS DWV cwD COLD WATER DROPPER
4. DOWNPIPES - PVC CLASS DW(UNO) cWR COLD WATER RISER
5. _ STORMWATER UP TO 300MM - PVC CLASS SWHEAW (UNO) DG DISCONNECTOR GULLY
DCV DOUBLE CHECK VALVE
ATER SERVICE NOTES DP DOWNPIPE
1. COLDWATER PIPEWORK 0 BE A MINIMUM OF 15MM TO INDMIDUAL OUTLETS/FXTURES AND 20mMaoR DUCV DUAL CHECK VALVE
GREATER TO MORE THAN ONE QUTLETS/FDXTURES (UNO). e OP INSON ont
2. 15MIM@ COLD WATER PIPEWORK TO BE A MAXIMUM LENGTH OF METRES AWG A AOR WASTE GULLY
3, WATER SUPPLY PIPE SIZES INDICATED ON THESE DRAWINGS ARE EQUVALENT TO TYPE B" COPPER TUBE IF LEATED WATER
USING AN ALTERNATIVE MATERIAL THE INTERNAL DAMETER OF THE PPE SHALL BEEQUALTOOR GREATER {5 HEATED WATER DROPPER
THAN THAT INDICATED ON THESE DRAWINGS, WR HEATED WATER RISER
4, HEATED WATER PIPEWORK SHALL BE 20MM FROM THE HEATER TO SHOWER BRANCH THEN 15MM TO ALL 5! HIGH LEVEL
OTHER OUTLETS/FIXTURES. WT NOSE TAP
5, WATER HEATERS IN CEILING SPACE SHALL HAVE THE ISOLATING VALVES BELOW CEILING. 0 INSPECTION OPENING
6. _ WATER PIPEWORK TO BE INSTALLED IN WALL FRAMING AND ABOVE CEILING (UNO). ios INSPECTION OPENING TO SURFACE
7. ALL HEATED WATER OUTLETS USED PRIMARLY FOR PERSONAL HYGIENE PURPOSES ARE TO BE TEMPERATURE < INSPECTION SHAFT
CONTROLLED 70 A MAXIMUM OF 50°C GENERALLY AND 45°C AT DISABLED ACCESS AREAS I INVERT LEVEL
8. HEATED WATER TO DISABLED ACCESS AREAS TO BE TEMPERATURE CONTROLLED BY A THERMOSTATIC MXING, ISOLATION VALVE
VALVE.
MH MANHOLE
AS CONSTRUCTED NOTES ORG OVERFLOW RELIEF GULLY
RPD REAL PROPERTY DESCRIPTION
1, AS CONSTRUCTED PLANS OF COMPLETED PLUMBING AND DRAINAGE SERVICES MAY BEREQUIREDBY gry SAFE TRAY
THELOCAL AUTHORITY, THE AS CONSTRUCTED PLANS, IF REQUIRED, SHALL BE SUBMITTED ATTHETIME wp SAFE WASTE DRAIN
OF, ORIMMEDIATELY FOLLOWING, THE FINAL ASSESSMENT OF COMPLETED WORKTHATISSUBJECTTO. py SANITARY DRAINAGE
THE COMPLIANCE PERMIT. sp SANITARY PLUMBING
2. IAN BRADFORD PLUMBING CONSULTANTS WILL PREPARE AS CONSTRUCTED PLANS FOR ADDITIONAL SHR SHOWER
FEE/S. (SOME PROJECTS MAY ALREADY INCLUDE THE COST TO PREPARE AS CONSTRUCTED PLANS - S SINK
CONTACT OUR OFFICE FOR DETAILS ON THIS PROJECT.) To TEST OPENING
3. MARKED UP PLANS OF AS CONSTRUCTED DETAILS ARE TO BEPROVIDED TO AN BRADFORD PLUMBING py TEMPERING VALVE
CONSULTANTS INA CLEAR & LEGIBLE MANNER. ADDITIONAL FEES WILL BE REQUIRED IF MARKED UP 106 TOP OF GRATE
PLANS ARE OF AN UNSATISFACTORY STANDARD. TID TRAPPED TUNDISH
4, IAN BRADFORD PLUMBING CONSULTANTS WILL PERFORM SITE INSPECTIONS OF THEINSTALLED WORK Tp TUNDISH
AND RECORD AS CONSTRUCTED INFORMATION FOR ADDITIONAL FEES, CONTACT OUROFFICEFORAFEE UNO UNLESS NOTED OTHERWISE
PROPOSAL. WH WATER HEATER
we WATER CLOSET
WM WATER METER

ALL WORKS TO COMPLY WITH THE QUEENSLAND PLUMBING & DRAINAGE ACT 2002 AND LOCAL AUTHORITY

A LOCALITY MAP

“N© scaents

LEGEND

COLD WATER

HEATED WATER

SANITARY

STORMWATER

VENT

EXIST SANITARY DRAINAGE
EXIST SEWER

EXIST TRADE WASTE

EXIST WATER

EXIST STORMWATER

     
 
   

 

 

 

 

eTWD

 

 

 

 

 

 

 

SITE - 28 HASTINGS STREET NOOSA HEADS

Hastings st

 

 

 

 

A 01/03/16] > CLIENT

B

 

ISSUE | DATE REVISION STATUS

 

 

 

DESIGNED

 

 

 

M - 0412654598
PO BOX 1251
NOOSAVILLE BC a4)
E - [email protected] neato ‘
Plumbing cons, ints

 

+ _W- www.ibplumbingco}

 

 

E
HYDRAULIC SERVICES
Cover Page

 

 

CLIENT DWG NO
Calambee Nominees Pty Ltd

 

 

A3 SCALE NTS U.N.O.

REV

15055 - 1 A

 

 

 

 

SHEET 1 OF 6

 

Used in these records

About this file

File size
2.7 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

OPW16_0078 - Operational Works Application.pdf · 2.7 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.