Council archive · source document
MCU16/0046 - Approved Plans
Plans and drawings: the text below has words only, no drawings.
KEY: TD THERMAL DETECTOR AREAS:
HT HOSE TAP SD SMOKE DETECTOR LOWER FLOOR: 106m²
*PRIOR AND DURING CONSTRUCTION ALL LEVELS, HEIGHTS AND MEASUREMENTS *THE BUILDER IS RESPONSIBLE TO CHECK ALL EXISTING SERVICES PRIOR TO
FG FLOOR GULLY HW HOT WATER
GARAGE/D-CAVITY: 46m²
TO BE CONFIRMED ON SITE IN ACCORDANCE WITH STATUTORY AUTHORITIES. BEGINNING CONSTRUCTION AND DESIGNER TO BE NOTIFIED. -
DP DOWN PIPE A/C AIR CONDITIONING
D DOOR DN DOWN GROUND FLOOR: 163m² NOOSA COUNCIL
W WINDOW UP UP UPPER FLOOR: 42m²
L
DH
LOUVRE
DOUBLE HUNG
F
WC
FRIDGE
WATER CLOSET
GFA 357m² APPROVED PLAN
RH
CSD
RAIN HEAD
CAVITY SLIDING DOOR
SH
N
SHOWER
TILED NICHE
COVERED TERRACES: 53m²
SITE COVER: 191.8m²/ 29.62%
MCU16/0146 6 JUN 1016
SD SURFACE SLIDING DOOR V VANITY
GD GLASS DOOR T TUB
SJD SEE JOINERY DRAWINGS S SINK
TED TO ENGINEERS DETAIL OV OVEN
TFD TO FUTURE DETAIL W/M WASHING MACHINE
RTH
TCR TO COUNCILS REQUIREMENTS F FRIDGE
SDD SEE WORKING DRAWINGS DETAIL P PANTRY NO
CRS COLORBOND ROOF SHEETING FD FEATURE DOOR
TRM TRIMDEK ROOF SHEETS PD PLUMBING DUCT
FR FLAT ROOF S SPITTER
. FALL DIRECTION SW STORM WATER
3 1
WD8.0 WD7.0
57°43'00"
35.827
2000
100x100mm
SHS (TED)
W10
L DRIVEWAY BELOW
W9
14 13 12 11 10 9 8 7 DN
6 5 4 200x45mm VERTICAL FEATURE
W11 3 2 TIMBERS w/65mm SPACINGS (SDD)
1
CT
6000
OV
RECESSED FR
147°43'00"
KITCHEN
10.769
FRAMELESS GLASS CBD 720D
BALUSTRADE (SDD) TIMBER
EXISTING RETAINING WALL
D4
.
SKYLIGHT PTY
MARCUS DUNE CT
S
OVERHEAD S
DECK 100x100mm
(SDD) ALTERNATING HORIZONTAL
TILES TIMBERS TO SPEC (SDD)
SHS (TED) CBD
DINING
50 in.
RL 20.000 VOS
m
AD
L
m
m
HE
LINE OF BULKHEAD
LK
LINE OF UPPER FLOOR &
BU
D4 GROUND FLOOR ROOF OVER
.
F
O
NE
147°45'10"
W12
LI
18.000
D3
. STUDY
TIMBER
LIVING 100x100mm
mm
TIMBER SHS (TED)
50 n.
n.
50
L
mi
mm
mi
6000
TERRACE
FALL
FALL
TILES
RL 19.930 VOS 100x100mm
FIREPLACE SHS (TED) W13
SKYLIGHT BATH
142°10'00"
2 (LOCATION TBC) 820D 2
100x100mm (SDD) SECRET TILES
7.265
SHS (TED) LINE OF UPPER FLOOR & SH STEPPERS TO SPEC
GROUND FLOOR ROOF OVER DOOR
WD7.0 W6
V PD WC
WD7.0
FG
GATE N
W8 TV (SJD) W7 GLASS POOL FENCE (TCR)
INTEGRATED ENTRY
DOOR (D2,SDD)
3/DP
4 3 2 1
ENTRY D2
WINDOW (SDD)
ACRYLIC POOL
TIMBER
RL 20.000 VOS
LAP POOL W5
15 15 14 131211 10 9 8 7 6 5 4 3 2 1
UP
VOLUME = 42.17m³ (approx)
MAX DEPTH = 1.8m
1.2m
0.9m
0.6m
0.3m
LINE OF VOID OVER (SDD)
HT DP
40x40mm VERTICAL TIMBERS
w/100mm SPACINGS TO FORM
OUTDOOR SHOWER
POOL SAFE BARRIER. MINIMUM
2000
3 1 TO SPEC
1.2m HIGH FROM FGL.
WD8.0 WD7.0
36.531
57°43'00"
Lot 25 on SP111721 25 MARCUS DUNE CT,
CASTAWAYS BEACH QLD 4567
SITE AREA: 647.425m²
LOCATION OF ALL SERVICES TO BE DETERMINED AND CONSIDERED PRIOR AND DURING CONSTRUCTION.
CLIENT: Graham Hennessy & Sandra Crisp PROJECT: DUNES 25
www.chriscloutdesign.com.au GENERAL NOTES:
Use written dimensions only. DO NOT scale drawings. Contractors SITE ADDRESS: Lot 25 on SP111721 25 Marcus Dune Ct, CASTAWAYS BEACH QLD 4567
PO BOX 135, NOOSAVILLE, QLD 4566 to verify all dimensions on site prior to commencing works. Site
E: [email protected] location in accordance with engineers details. These drawings are to DRAWING TITLE: GROUND FLOOR PLAN
P: (07) 54748 107 be read in conjunction with engineers design and details, the
accompanying building specification and schedule of finishes. If in DATE: 17/12/15 SCALE: 1 : 100 @ A2 DRAWN BY: C.CLOUT
F: (07) 54748 108 BSA LICENCE: 1127508
doubt, please request clarification. DO NOT ASSUME.
ISSUE: WORKING DRAWINGS FOR CONSTRUCTION
WD2.0
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
MCU16/0046 - Approved PlansRelated documentApplication case desk ↗
About this file
- File size
- 3.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.