Council archive · source document
7550A_Neptune Ct Jetty_Construction Issue · OPW19/0108
Attached to the e-mail Operational Works Application OPW19/0108 - DA Form 1, Plans - 4 Neptune Circuit Noosaville.
File:_C:\- Projects\00 - Black & More\Noosa Jetty Builders\7550 4 Neptune Circuit\ 75504 - Notes Sheet.dwg TIMBER FRAMING & BRACING: 1 T2 T3 14 15 T6 T7 T8 T9 T10 T11 T12 T13 114 T15 T16 ALUMINIUM: ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS 1720, AS 1684 MINIMUM SPACING, EDGE & END DISTANCES FOR NAILS AND SCREWS A1. ALL WORKMANSHIP AND MATERIALS SHALL COMPLY WITH BEST PRACTISE ALUMINIUM AND THE REFERENCED STANDARDS THEREIN. FABRICATION AND THE CURRENT AUSTRALIAN STANDARD AS 1664. MINIMUM DISTANCE A2. ALUMINIUM SECTIONS SHALL COMPLY WITH AS 1734, AS 1886 OR AS 1867. ALL FRAMING, BRACING AND TIE-DOWN INFORMATION FORMS THE BASIS OF THE A3. ALL WELDING SHALL COMPLY WITH AS 1665. STRUCTURES STABILITY DOWN TO FOUNDATIONS. ALTERNATIVE METHODS SHALL SPACING TYPE HOLES FOR HOLES FOR A4. ALL WELDING SHALL BE CARRIED OUT USING ARGONGAS SHIELDING. WELD ONLY BE ACCEPTED ON APPROVAL OF THE ENGINEER. NAILS NOT NAILS PREBORED | SCREWS. CONSUMABLES SHALL BE COMPATIBLE WITH BOTH PARENT ALLOYS IN ACCORDANCE PREBORED TO 80% DIA. WITH AS AS 1665. FOR 6063-T6 USE 4043 FILLER WIRE. PLATE-TO-EXTRUSION ALLOYS PREFABRICATED TIMBER ROOF TRUSSES, PROPRIETARY FLOOR JOIST SYSTEMS END DISTANCE 20D 10D 10D SHALL BE WELDED USING APPROPRIATE FILLERS IN ACCORDANCE WITH WTIA AND ALTERNATIVE TIMBER ELEMENTS TO THOSE SHOWN ON THE ENGINEERING EDGE DISTANCE 5D 5D 5D TECHNICAL NOTES WHERE NOT COVERED BY AS 1665. DRAWINGS ARE TO BE DESIGNED AND CERTIFIED BY THE SUPPLIER'S STRUCTURAL ALONG-GRAIN SPACING 20D 10D 10D AS. ALL WELDS SHALL BE A MINIMUM 5mm CONTINUOUS FILLET WELD ALL ROUND, ENGINEER. DESIGN AND INSPECTION CERTIFICATES FOR THESE ELEMENTS ARE TO BE CROSS-GRAIN SPACING 40D 3D 3D UNLESS NOTED OTHERWISE. A6. ALUMINIUM EXTRUSIONS SHALL BE STRUCTURAL GRADE ALLOY:- EXTRUSIONS 6063-T6 ISSUED TO THE CONTRACTOR FOR LODGEMENT WITH THE LOCAL AUTHORITY. UNLESS NOTED OTHERWISE. A7. ALUMINIUM PLATE IS TO BE WROUGHT GRADE ALLOY 5083 H116. ALL TIMBER MEMBERS USED ARE TO HAVE A MINIMUM LEVEL OF DURABILITY AS A8. ALL STEEL AND STAINLESS STEEL BOLTS AND ALL OTHER FIXINGS MUST BE ISOLATED SPECIFIED IN AS1684.2 - APPENDIX B. FROM ALUMINIUM USING NYLON OR SIMILAR APPROVED PACKERS/GASKETS, AND ALL HWD TIMBER SHALL BE SEASONED UNO. WASHERS WITH SHANK COLLARS. AQ. SHOP DETAIL DRAWINGS ARE TO BE SUBMITTED TO THE ARCHITECT AND ENGINEER FOR REVIEW. APPROVAL IS TO BE OBTAINED FROM THE COUNCIL, THE ARCHITECT AND ALL TIMBER SHALL BE FREE OF GUM VEINS, KNOTS, SHAKES, CHECKS, WANES AND ANY THE ENGINEER, PROIR TO COMMENCING FABRICATION. OTHER IMPERFECTIONS WITHIN CONNECTION ZONES. ALL TIMBER FRAMING TO BE MINIMUM H6 TREATED UNO. EXPOSED FRAMING (TIMBER FRAMING THAT MAY BE SUBJECT TO PERIODIC WETTING): - SHALL BE EITHER H6 PRESSURE TREATED OR DURABILITY CLASS 1 SPECIES (MINIMUM) SAWN TIMBER (UNO) WASHERS SHALL BE PROVIDED UNDER ALL NUTS AND BOLT HEADS (EXCEPT CUP-HEAD BOLTS) BEARING AGAINST TIMBER AS FOLLOWS: BOLT SIZE WASHER <=M12 50X50X3.0mm M16 57X57X4.0mm M20 65X65X5.0.mm >M20 75X75X6.0mm X..... INDICATES M12DIA ANCHOR ROD/BOLT [X]..... INDICATES M16DIA ANCHOR ROD/BOLT SB.... INDICATES STRAP BRACE ROOF BRACING FIXED TO TOP OF EACH JOIST WITH 2 SCREWS. BEND STRAP BRACING OVER AT ENDS, FIX WITH 2 SCREWS TO TOP OF JOIST AND 4 SCREWS TO SIDE FACE OF SUPPORTING MEMBER. ALL ROOFS TO BE BRACED. ALL FASTENERS ARE TO BE GRADE A4-70 STAINLESS STEEL IN ACCORDANCE WITH ISO-3506-1. EXTERNAL ANCHORS WHERE SUBJECT TO SALT AIR SHALL BE STAINLESS STEEL A4-70: -SCREWS TO BE NO.14 TYPE 17 WITH 50MM EMBEDMENT (UNO) -ALL JOIST HANGERS, FRAMING ANCHORS, TRIPLE GRIPS AND THE LIKE, SHALL BE STAINLESS STEEL. TO BE MANUFACTURED BY PRYDA OR APPROVED EQUIVALENT, WITH 5 NO. 2.8mm DIA X 30MM NAILS EACH LEG MINIMUM. INSTALL AS PER MANUFACTURERS SPECIFICATION. PROVIDE BLOCKING OVER SUPPORTS AT 1800 MAX CRS INACCORDANCE WITH AS 1684 FOR TIMBER BEARERS AND JOISTS WITH D/B >= 4. FOR JOISTS WITH SPAN >3000 AND BOTTOM OF JOIST UNRESTRAINED BY CEILING DIAPHRAGM: -PROVIDE 1 ROW OF BLOCKING BETWEEN EACH JOIST AT MIDSPAN FOR SPANS < 4200mm -PROVIDE 2 ROWS OF BLOCKING BETWEEN EACH JOIST AT THIRD POINTS FOR SPANS >4200mm FIXING LOCATIONS TO BE FIXED ACCORDING TO THE FOLLOWING MINIMUM PACINGS (D = FIXING SHANK DIA. IN mm): BOLTS 4D EDGE DISTANCE TO BOTH EDGES IN DIRECTION OF SHEAR LOAD 5D PITCH BETWEEN BOLTS 5D EDGE DISTANCE FROM END OF ELEMENT 13D MINIMUM OVERALL ELEMENT DEPTH CONSTRUCTION ISSUE Printed: 05 April 2019, 11:29 AM Y, Y Yr NOOSA JETTY BUILDERS | ©diecka ns Ghent Project Drawing Tie JoB No: 1154 Ay socunent and shall remain. BEN 18 904 800 232 NOOSA JETTY BUILDERS PROPOSED NEW JETTY GENERAL NOTES SHEET 2 OF 2 m Addtaes: the property of Black & More. Address - i ume 93 Digger St Cairns North QLD 4870 : NEPTUNE CRCUT-NOOSAVLLE | Ein emenr ramen et lacks) 22S. 4 NEPTUNE CIRCUIT, NOOSAVILLE | 3 ind in accordance Di Di rT a D: 2 lent aah ie Torneo uaaeiant ok Tetprone or donigoea | pet st fehecr’ ar Penn ste 05/048 C1 [CONSTRUCTION ISSUE Fi | Fit [05/04/19 | SAVIN AND CHARMAINE SWART J on on nom OLE ke. eemreen Designed Design = apea 79957 _| "wna Sze| Seale (AS size) pane 7550A-S003 Revision No. Description Reviewed] Approved] Date ‘whatsoever is prohibited. t IL FM [check 2S [BrawipGis notte fe dsed for consiruclion unless approved A3 NOT TO SCALE C1 J < External References: B&M-JETTY-TITLE-A3_e.dwg
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
7550A_Neptune Ct Jetty_Construction Issue.pdfRelated documentApplication case desk ↗
About this file
- File size
- 6.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.