Original source · versioned page text
Architecturals
‘ ALL LOCATIONS HEIGHTS AND SWITCHES WILL BE
PLACED BY THE CLIENT AT THE ELECTRICAL
WALKTHROUGH ONSITE DURING THE BUILD’
D.P D.P
ELECTRICAL LEGEND
18-18SW 09-06SW OBS CODE TYPE
D.P
WEATHERPROOF SINGLE POWER POINT (GPO)
DOUBLE GPO TO
1,800 sliders
ALFRESCO - 2 DOUBLE POWER POINT (GPO)
clothesline
USB
820 CSD
DOUBLE POWER POINT + USB (GPO)
12-18SW
LED DOWN LIGHT POINT
21-24 SD
21-30 STACKER
F CEILING CIRC FLURO LIGHT POINT
OYSTER LIGHT POINT 300 - 400
D.P
820 PENDANT LIGHT
720
SMOKE DETECTOR
09-06SW D.P 12-15SW OBS
21-30 STACKER
820
820 CSD
820 PHONE POINT
G.HWS
TV POINT
MH
720 CSD
720 CEILING EXHAUST FAN
720
S-GPO FOR
GAS HWS 2 2 HEATER LIGHT FAN
720
4 4 HEATER LIGHT FAN
WM
gas bottles by owner
SINGLE STRIP FLUORO
820
DOUBLE STRIP FLUORO
RH DW
1,600 sliders BUNKER LIGHT
820
USB MW S-GPO ON CEILING
FOR AUTO DOOR SENSOR LIGHT UNIT
REF. DAZ WALL LIGHT
D DATA POINT
1,200 sliders
18-12SW 18-18SW
D.P M. BOX
CEILING FAN
D.P
D.P
D.P
CEILING FAN LIGHT
18-18SW 18-18SW
smoke detectors to be hard
wired with battery backup
& interconnected with one another
ELECTRICAL PLAN
SCALE 1:100
NOTES PLAN LEGEND CLIENT:
PLEASE READ CAREFULLY
10. Protection against subterranean termites shall be in accordance with AS
1. Written dimensions take precedence over scale. 3660-Pt 1 2001. Provided treatment: Visual Barrier System to perimeter with afl = above floor level ref = refrigerator prov. THIS PLAN CERTIFIED CORRECT IS THE ONE REFERRED TO IN THE D. COUTTS & A. BRETT
CONTRACT & SPECIFICATIONS AND I UNDERSTAND CHANGES
2. Builder to verify all dimensions and levels prior to commencement of construction. approved collars/barriers at slab penetrations. hd = head at 2100 afl. mw = microwave prov. HEREAFTER MAY NOT BE POSSIBLE. THESE PLANS SUPERCEDE ALL
3. All internal dimensions stated are frame size - excluding linings. 11. HWS unit (constant flow) with 5 star energy efficiency rating to comply fw = floor waste dw = dishwasher prov. OTHER PREVIOUS PLANS OR SKETCHES.
4. This building has been designed in accordance with AS 1684.2 - 2006 (Residential with "Sustainable Buildings" QDC pt 29, AS/NZs 6400:2005. = smoke detector pty = pantry Lot 31 Butcherbird Lande
timber framed construction). 12. Rainwater tanks, lighting and plumbing fixtures & fittings to comply with QDC vb = vanity basin wm = washing machine prov. RIDGEWOOD
Stroud Homes Pty Ltd 5. Supplier may substitute lintels for those of equal strength to span ratio. PART 29 & 25, 'Sustainable Buildings' QDC pt 29 & 25 AS/Nzs 300.1.2003 obs = obscure glazing ghw = gas hot water unit
ABN: 49 107 897 736 QBSA Lic No: 1083367 6. All structural sizes to be read in-conjunction with structural engineers drawings & AS/NZS 6400:2005. mb = meter box tr = towel rail MODEL: JOB
OWNER/S 20L031BU
details. 13. Lift off hinges to all WC doors to comply with Australian Standards. dp = downpipe trh = toilet roll holder Springleigh 204 Classic No.
107 Sugar Road Telephone: Email: 7. Articulation joints to complay with 3.3.1.8 BCA Vol 2. 14. Stair construction to comply with Pt 3.9.1 and balustrades to comply with pt ohc = overhead cupboard HC = garden tap
WITNESS DATE
Maroochydore 07 5444 2521 Daniel.chapman 8. Mechanical Ventilation to comply with 3.8.5 Bca Vol 2. 3.9.2 BCA Vol 2. ISSUE/DATE: SHEET
QLD Mobile: @stroudhomes. No.
9. Smoke alarms to comply with 3.7.2 BCA Vol 2 (wired-in) 15. DCP & flashings to comply with Pt 3.3.4 BCA Vol 2
4558 0402 864 305 com.au C 2017 REPRODUCTION IN PART OR WHOLE IS STRICTLY FORBIDDEN
PRELIM ISSUE 1 : 03/11/20 6 OF 08
GSPublisherVersion 0.0.100.100
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.