     Codes
                      Column 1                                       Column 2                                                Column 3
                Specific Outcomes                      Probable Solutions (if code assessable)                              Compliance
O13 For the Attached Housing Zone the maximum
gross floor area is equivalent to the maximum                                                          Not applicable
allowable population in persons multiplied by 40m2

Flooding and drainage71
O17 Buildings and other works are designed and         S17.1 For new buildings or structures or        S17.1 Complies - Existing building to be utilised not new
sited to—                                              additions of more than 50m2 gross floor         floor area proposed.
a) provide flood free access to premises and flood     area to an existing building or structure,
free habitable areas;                                  floor levels for habitable rooms are not less
b) allow only minor, short term and infrequent         than the specified minimum floor levels;
flooding of non-habitable areas;                       AND
c) ensure carparking areas can be adequately           S17.2 Where Council infrastructure is           S17.2 Applicant will comply with relevant requirements.
drained;                                               available—
d) ensure drainage does not adversely impact           a) any drainage (including buildings and
upon other premises; and                               yards) flows to that infrastructure; and
e) ensure filling or excavation does not adversely     b) the infrastructure has the capacity to
impact upon other premises by—                         accept any additional loading;
i. causing ponding on the site or nearby land;         AND
ii. increasing flooding, which adversely affects the   S17.3 For Residential Uses—                     Not applicable.
safety or use of any land upstream and                 a) where slab on ground construction is
downstream; and                                        used, filling does not extend more than 1m
iii. adversely affecting the flow of water in any      beyond the building footprint and access to
overland flow path.                                    car parking areas, measured from the outer
                                                       walls of the building ; or
                                                       b) the design consists of a suspended floor
                                                       construction;
                                                       AND
                                                       S17.4 Car parking and maneuvering areas         Complies
                                                       are constructed at a level that permits the
                                                       parking area to drain from the site by
                                                       gravity means, without the need for
                                                       mechanical pumping;
                                                       AND
                                                       S17.5 Basements for residential uses have       Not applicable
                                                       flood immunity above the Q100 where
                                                       alternative means to mechanical pumping
                                                       are used to achieve such immunity; or
                                                       S17.6 Basements for non-residential uses        Not applicable
                                                       have flood immunity above the Q100 that
                                                       may be achieved by means of mechanical


     Noosaville locality - 01824 Neylan                                                                                                   Page6

Used in these records

About this file

File size
449 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Annexure B - Codes.pdf · 449 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.