Council archive · source document
Annexure B - Codes · OPW15/0072
Attached to the e-mail MCU15/0038 & OPW15/0072 Development Application.
Codes
Column 1 Column 2 Column 3
Specific Outcomes Probable Solutions (if code assessable) Compliance
O13 For the Attached Housing Zone the maximum
gross floor area is equivalent to the maximum Not applicable
allowable population in persons multiplied by 40m2
Flooding and drainage71
O17 Buildings and other works are designed and S17.1 For new buildings or structures or S17.1 Complies - Existing building to be utilised not new
sited to— additions of more than 50m2 gross floor floor area proposed.
a) provide flood free access to premises and flood area to an existing building or structure,
free habitable areas; floor levels for habitable rooms are not less
b) allow only minor, short term and infrequent than the specified minimum floor levels;
flooding of non-habitable areas; AND
c) ensure carparking areas can be adequately S17.2 Where Council infrastructure is S17.2 Applicant will comply with relevant requirements.
drained; available—
d) ensure drainage does not adversely impact a) any drainage (including buildings and
upon other premises; and yards) flows to that infrastructure; and
e) ensure filling or excavation does not adversely b) the infrastructure has the capacity to
impact upon other premises by— accept any additional loading;
i. causing ponding on the site or nearby land; AND
ii. increasing flooding, which adversely affects the S17.3 For Residential Uses— Not applicable.
safety or use of any land upstream and a) where slab on ground construction is
downstream; and used, filling does not extend more than 1m
iii. adversely affecting the flow of water in any beyond the building footprint and access to
overland flow path. car parking areas, measured from the outer
walls of the building ; or
b) the design consists of a suspended floor
construction;
AND
S17.4 Car parking and maneuvering areas Complies
are constructed at a level that permits the
parking area to drain from the site by
gravity means, without the need for
mechanical pumping;
AND
S17.5 Basements for residential uses have Not applicable
flood immunity above the Q100 where
alternative means to mechanical pumping
are used to achieve such immunity; or
S17.6 Basements for non-residential uses Not applicable
have flood immunity above the Q100 that
may be achieved by means of mechanical
Noosaville locality - 01824 Neylan Page6
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Annexure B - Codes.pdfRelated documentApplication case desk ↗
Annexure B - Codes.pdfRelated documentApplication case desk ↗
About this file
- File size
- 449 KB (small file)
- File type
No other editions are linked here.