Original source · versioned page text
Sealed Judgment (4 Arakoon) - 26.05.26
area
sewer manhole
timber
erosion prone
stormwater manhole S
building
g line
existing trees to be
l buildin
removed
gully trap
coasta
deck
existing tree to be
I 10° 30 041m
' 135''
site bo
undary
I
removed and replaced
40.234
I 7.
nt
m appr
ox I 10
demolish existing shed 0° 30'
ce
undary
135''
res
approx
site bo
existing trees to be demolish existing
nc
removed and replaced retaning walls
k oo
proposed concrete
driveway
ara
784
approx I 6° I 8.067m
RP48111
51' 135''
pressure sewer 604m2
ary
unitywater records
site bound
thick vegetation
135''
demolish existing pool demolish existing
0° 30'
and paving retaning walls
power pole
ox I 19
existing tree to be demolish existing existing trees to be
retaning walls removed
m appr
removed and remove existing
replaced fence and gate remove existing garden
15.088
existing trees requiring
I
undary
existing concrete removal - arborist to advise
driveway to be removed on removal process
site bo
remove existing site bo
undary existing tree to be
I 39.721
driveway and drawinge m appr
ox I 10 removed and replaced
784 0° 30'
135''
existing block retaning RP48111 demolish existing stair
site boundary I 15.5
wall to be demolished
570m2
existing tree to be demolish existing terrace
removed and replaced
thick vegetation
70m approx I 356°
pressure sewer demolish existing two
unitywater records storey timber building
existing tree to be
135''
08' 135''
removed and replaced
0° 30'
remove existing paving
ox I 19
ar
m appr
ak
retain existing walls
oo
15.088
nc
re
I
undary
sc
en
site bo
t
site bo demolish existing
undary
I 35.858
m appr
paving
ox I 28
0° 30'
135''
deck
multi storey
building
demolition notes
1. demolition or removal of all structures to comply with AS2601.
2. remove all elements shown hatched
3. remove existing landscaping, and trees where noted
4. all services (power, gas, water, etc.) to be disconnected.
5. plumbing drains and sewer main to be sealed and capped.
contractor to obtain plumbing approval from council
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0428
aca A 12/04/2024 internal review 4-6 Arakoon Crescent BV Investments Pty Ltd southern house SD S180.00 D SCALE As indicated
aca B 18/04/2024 client review Sunshine Beach QLD 4567
A3
demolition plan
aca C 11/06/2024 DA issue review
aca D 12/12/2025 ADR registrar response
schematic design 1:1 @
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.