Council archive · source document
Approved Plans - MCU19-0055 & OPW19-0115 · MCU19/0055
Plans and drawings: the text below has words only, no drawings.
Very large file (10.3 MB): may take a few minutes to open.
Original PDF page 6, section 1. The text section number identifies this passage in the reader.
600 600 600 600 600
Colorbond Custom orb roof sheeting
fixed to manufacturers specification
for required wind category. (5° pitch).
Colorbond slotted gutter, fascia
to match roofing. Fix to manufacturers
specification.
Rendered foamboard cladding fixed to
Ceiling Height
manufacturers specification.
2700
Joinery
2400
Aluminum framed windows
600 to manufacturers specification.
Rendered brick veneer
Ceiling Height
walls to engineers details.
2700
Joinery
2400
Unit B F.F.L.
600
Unit A F.F.L.
Approx. Existing Ground Line.
Approx. Proposed Ground Line.
Colorbond Custom orb roof sheeting
SOUTH ELEVATION
fixed to manufacturers specification
for required wind category. (5° pitch). Rendered foam extrusion for articulation of
Colorbond slotted gutter, fascia 600 600 600 the wall fixed to manufacturers
to match roofing. Fix to manufacturers specification.
specification.
5°
Approved frameless glass pool fence to
200 series blockwork wall to engineers
manufacturers specifications.
detail.
Min. 1200mm high.
Rendered foamboard cladding fixed to
Ceiling Height
manufacturers specification.
2700
Joinery
2400
Aluminum framed windows
5° to manufacturers specification.
Ceiling Height
2700
Joinery
2400
Rendered brick veneer
walls to engineers details.
-
APPROVED PLANS
MCU19/0055 & OPW19/0115
Approx. Proposed Ground Line. NOOSA COUNCIL
Approx. Existing Ground Line. 16 JULY 2019
-
WEST ELEVATION
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.
Revision Schedule Client Name: Andy & Pamela Pannifex
Sheet Number:07 Project Number:18-076
Revision Number Revision Description Revision Date Issued by Project Address: No. 27 Hill Street, Sunshine Beach
2 PCD 3 28/02/2019 AOW
Climate Zone: 2
3
4
Concept Set 1.1
Development Application
03/03/2019
03/05/2019
BJH
BJH Wind Category: To engineers spec.
Elevations
Email: [email protected] 1.0
Website: www.iconbuildingdesign.com.au Project Issue Date: 30/06/2019 Project Status: Development Application 1.0 Scale: 1 : 100
5 RFI 1.0 30/06/2019 BJH
Phone: 0488209840 Checked/Signed By Director: Bradley Hunt Drawn By: BJH QBCC LIC# 126221
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plans - MCU19-0055 & OPW19-0115.pdfRelated documentApplication case desk ↗
About this file
- File size
- 10.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file