Council archive · source document
06/2689 - Request for further Info [As Published] · 132006.2689
In this regard the applicant will need to arrange a surveyor to establish the
invert levels of Council’s existing drainage system and demonstrate how
the basement will be drained to this drainage system. If this cannot be
achieved the applicant will need to investigate the option of raising the
basement level (to ensure the basement can drain by gravity means)
and/or upgrading the existing Council drainage system such that it is at a
level that can drain the basement carpark. These issues will need to be
resolved prior to Council issuing a Development Permit for the proposed
Material Change of Use, as Council must be sure that the development is
suitable and can actually work.
Car Parking
5. Demonstrate that the proposed driveway and carparking area comply with all
aspects of the Australian Standard (AS2890.1) for Parking Facilities, Part 1: Off
Street Car Parking.
5.1. In this regard it is noted that the present proposal contains, blind corners
and blind aisles with no provision for vehicles to turn around. As such,
designated turning bays must be provided and it is recommended that they
be at least 3m wide (to allow ease of access and departure) and at least
5.4m long. To this end:
One turning bay should be provided adjacent to the proposed
stairs located at the south-eastern corner of the basement (space
number 30), and
One turning bay should be provided on the eastern side of the
basement, immediately to the north of the proposed tank (space
number 22).
5.2. The proposed driveway ramp that provides access to the carpark needs to
be amended as:
It appears that two laneways will need to be separated by a cental
median, with each lane having a minimum width of 3.9m measured
between kerbs.
The proposed ramp grades must be determined by the inside radius of
the ramp (i.e. where the ramp grades will be steeper) not the middle of
the ramp.
Headroom between the ramp and the entrance to the basement
carpark must be designed such that vehicles will not hit the upper
level, as this will require changes to the upper level and/or the
driveway grades.
5.3. Amend the proposal plan such that clear access is available to all stairs
cases. In this regard it is noted that clear access cannot be obtained to the
proposed stair at the south-eastern corner of the upper level carpark. A
clear passage of at least 1.5m in width should be available to the stairs,
free of any carparking spaces or wheel-stops that would impede pedestrian
movements.
Award Winner - Australian Clean Beach
Challenge 2004 Litter Prevention
See the original